• Title/Summary/Keyword: pulse load

검색결과 530건 처리시간 0.028초

철도안전법과 도시철도안전법을 적용한 도시형 자기부상열차의 충돌안전도 해석 (Crashworthiness Analysis of the Urban Maglev Vehicle according to Korean Railway Safety Law and Urban Transit Safety Law)

  • 이현철;구정서
    • 한국자동차공학회논문집
    • /
    • 제17권5호
    • /
    • pp.115-126
    • /
    • 2009
  • This paper studied on the application of the crashworthiness regulations of Korean Railway Safety Law and Urban Transit Safety Law to the urban Maglev vehicle of KIMM. The Urban Maglev vehicle has to comply with the crashworthiness regulations for urban transit vehicles. The collision load cases have been simulated by using explicit finite element analysis. From the numerical results, the crashworthiness regulations of the Urban Transit Safety Law were completely satisfied, but maximum crash pulse requirement in 25 km/h crash event and no plastic deformation requirement in 10 km/h crash event in the Korean Railway Safety Law were not. If a commercial urban Maglev vehicle is developed in the near future, it is necessary that some soft buffing and energy absorbing devices are adopted in its front end so as to satisfy the crashworthiness regulations of the Korean Railway Safety Law.

델타변환 무정전전원장치 시스템의 특성 시험 (Test on Characteristics of Delta Conversion UPS System)

  • 지준근
    • 한국산학기술학회논문지
    • /
    • 제6권6호
    • /
    • pp.491-496
    • /
    • 2005
  • 본 논문에서는 일명 델타변환 무정전전원장치(UPS)로서 알려져 있는 3상 라인 인터랙티브 UPS 시스템의 성능 시험에 대해서 다루고 있다. 델타변환 UPS는 종래의 단일 변환 라인 인터랙티브 UPS 시스템에서 직렬 인덕터를 제거하고 직렬 및 병렬 PWM(Pulse Width Modulation) 컨버터를 사용하는 새로운 라인 인터랙티브 UPS 시스템으로 전원 전류를 직접 제어함으로써 UPS 시스템의 입출력 특성들이 상당히 개선되는 것으로 알려져 있다. 여기서는 UPS 시스템의 성능 시험에서 중요한 내용들인 부하시험, 정전/복전시험, 동기절체 시험 등에 대한 결과들을 제시하고 델타변환 UPS 시스템에 대한 전반적인 평가를 한다.

  • PDF

DUAL DUTY CYCLE CONTROLLED SOFT-SWITCHING HIGH FREQUENCY INVERTER USING AUXILIARY REVERSE BLOCKING SWITCHED RESONANT CAPACITOR

  • Bishwajit, Saha;Suh, Ki-Young;Lee, Hyun-Woo;Mutsuo, Nakaoka
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.129-131
    • /
    • 2006
  • This paper presents a new ZVS-PWM high frequency inverter. The ZVS operation is achieved in the whole load range by using a simple auxiliary reverse blocking switch in parallel with series resonant capacitor. The operating principle and the operating characteristics of the new high frequency circuit treated here are illustrated and evaluated on the basis of simulation results. It was examined that the complete soft switching operation can be achieved even for low power setting ranges by introducing the high frequency dual duty cycle control scheme. In the proposed high frequency inverter treated here, the dual mode pulse modulation control strategy of the asymmetrical PWM in the higher power setting ranges and the lower power setting ones, the output power of this high frequency inverter could introduce in order to extend soft switching operation ranges. Dual duty cycle is used to provide a wide range of output power regulation that is important in many high frequency inverter applications. It is more suitable for induction heating applications the operation and control principle of the proposed high frequency inverter are described and verified through simulated results.

  • PDF

펄스전원용 고압커패시터 충전기 시험 (The Experiment of High Voltage Capacitor Charger for Pulsed Power Application)

  • 장성록;안석호;류홍제;김종수;김영배;김진성;이병하;김성호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1025_1026
    • /
    • 2009
  • This paper introduces the test a rapid pulsed power charging system for pulsed power application. The charger is designed based on three-phase series resonant inverter followed by air cooled step-up transformers. It has many advantages of lower weight, small size and high efficiency compared with large bulky traditional pulse power charging system. To apply 150kJ pulsed power system, detail test was carried out at various condition and its results shows 90% efficiency at full load condition. And additional experiments such as short, open, and self discharging during charging status are performed to verify reliable operation at abnormal condition and it was confirmed that developed capacitor charger showed very reliable operation all over the tests.

  • PDF

대면적 Ag 그리드 DSC 모듈을 활용한 AC 220V 상용 전원장치에 대한 연구 (A study on AC 220V common power supply system using large area DSC module with Ag grid)

  • 김희제;서현웅;김미정;홍지태;심지영;이상목;김호성
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.254-256
    • /
    • 2007
  • The Solar energy is either used as a solar thermal energy or converted to electrical power through power conversion system. The latter method is defined as a solar cell changing the solar energy into the direct electric energy or power conversion that convert the dc power into ac power.For the solar cell to be a practical alternative energy, the study should be focused not only on the solar cell ,but also the power conversion system for common power source. In this study, we get the suitable power to common load ,using Ag Grid DSC(Dye-sensitized solar cell). Our purpose is to achieve the common solar cell power generation system ,using converter and PWM(Pulse width modulation) inverter system controled by DSP.

  • PDF

초음파 진동이 알루미늄 합금의 마찰 마모 특성에 미치는 영향 (Effect of Ultrasonic Vibration on the Friction and Wear Characteristics of Aluminum Alloy)

  • 박재남;이철희
    • Tribology and Lubricants
    • /
    • 제34권4호
    • /
    • pp.132-137
    • /
    • 2018
  • Ultrasonic waves are used in various applications in multiple devices, sensors, and high-power machinery, such as processing machines, welders, and cleaners, because the acoustic vibration frequencies are above the human audible frequency range. In ultrasonic machining, electrical energy at a high frequency of 20 kHz or more is converted into mechanical vibration by a vibrator and an amplifier. This technique allows instantaneous separation between a tool and a workpiece during machining, machining by pulse impulse force at the time of re-contact and minimizes the minute elastic deformations of the workpiece and machine tools due to the cutting effect. The Al7075 alloy used in this study is a typical aluminum alloy with superior strength that is mainly used in aircrafts, automobiles, and sporting goods. To investigate the optimal conditions for machining aluminum alloy using ultrasonic vibration, the present experiment utilized the Taguchi orthogonal array method, and the coefficient of friction was analyzed using the characteristics of the Taguchi technique. In ultrasonic friction and abrasion tests, the changes in the friction coefficient were measured in the absence of ultrasonic vibrations and at 28 kHz and 40 kHz. As a result, the most considerable influence on the friction coefficient was found to be the normal load, and the frequency of ultrasonic vibrations increases, the coefficient of friction increases. It was thus confirmed that the amount of wear increases when ultrasonic vibration is applied.

멀티레벨 인버터의 순간정전 보상알고리즘에 관한 연구 (Voltage Dip Compensation Algorithm Using Multi-Level Inverter)

  • 윤홍민;김용
    • 조명전기설비학회논문지
    • /
    • 제27권12호
    • /
    • pp.133-140
    • /
    • 2013
  • Cascaded H-Bridge multi-level inverters can be implemented through the series connection of single-phase modular power bridges. In recent years, multi-level inverters are becoming increasingly popular for high power applications due to its improved harmonic profile and increased power ratings. This paper presents a control method for balancing the dc-link voltage and ride-through enhancement, a modified pulse width-modulation Compensation algorithm of cascaded H-bridge multi-level inverters. During an under-voltage protection mechanism, causing the system to shut down within a few milliseconds after a power interruption in the main input sources. When a power interruption occurs finish, if the system is a large inertia restarting the load a long time is required. This paper suggests modifications in the control algorithm in order to improve the sag ride-through performance of ac inverter. The new proposed strategy recommends maintaining the DC-link voltage constant at the nominal value during a sag period, experimental results are presented.

연료 전지 시스템을 위한 Z-소스 인버터고 구성된 병렬 운전 시스템 (Parallel Operation Systems of Z-Source Inverters for Fuel Cell Systems)

  • 문현욱;정은진;김윤호
    • 전력전자학회논문지
    • /
    • 제10권5호
    • /
    • pp.443-449
    • /
    • 2005
  • 본 논문에서는 연료 전지 시스템을 위한 Z-소스 인버터로 구성된 병렬 운전 시스템을 제시 하였다. PWM 방식으로는 Carrier phase shifted SPWM을 적용하였으며 이 방식은 출력 전류의 고조파 성분을 줄일 수 있는 장점을 갖는다. 그러나 이 기법을 Z-소스 인버터로 구성된 병렬 운전 시스템에 적용하는 경우 추가적으로 순환 전류를 발생한다. Z-소스 인버터로 구성된 병렬 운전 시스템이 동작 시 발생하는 순환 전류를 분석하고 순환 전류를 감소시키며, 부하전류에 낮은 고조파 성분을 가질 수 있도록 순환 전류 리액터를 사용하였다. 이에 대한 적합성을 시뮬레이션과 실험을 통해 입증하였다.

A Control Strategy Based on Small Signal Model for Three-Phase to Single-Phase Matrix Converters

  • Chen, Si;Ge, Hongjuan;Zhang, Wenbin;Lu, Song
    • Journal of Power Electronics
    • /
    • 제15권6호
    • /
    • pp.1456-1467
    • /
    • 2015
  • This paper presents a novel close-loop control scheme based on small signal modeling and weighted composite voltage feedback for a three-phase input and single-phase output Matrix Converter (3-1MC). A small non-polar capacitor is employed as the decoupling unit. The composite voltage weighted by the load voltage and the decoupling unit voltage is used as the feedback value for the voltage controller. Together with the current loop, the dual-loop control is implemented in the 3-1MC. In this paper, the weighted composite voltage expression is derived based on the sinusoidal pulse-width modulation (SPWM) strategy. The switch functions of the 3-1MC are deduced, and the average signal model and small signal model are built. Furthermore, the stability and dynamic performance of the 3-1MC are studied, and simulation and experiment studies are executed. The results show that the control method is effective and feasible. They also show that the design is reasonable and that the operating performance of the 3-1MC is good.

마이크로 컴퓨터를 이용한 동기 전동기의 최대 효율제 (Microcomputer-Based Maximum Efficiency Control of a Synchronous Motor.)

  • Hyun, Dong-Seok;Park, Min-Ho
    • 대한전기학회논문지
    • /
    • 제36권12호
    • /
    • pp.874-887
    • /
    • 1987
  • The efficiency of a synchronous motor can be substantially improved by controlling armature voltage, field excitation, and load angle on optimum values which yield minimum input power at any specified torque and speed. This improvement is particularly noticeable in the case of light loads. In addition, the control of armature input voltage improves the power factor at which the motor operates. Employed in the analysis is a new equivalent circuit model of the motor which incorporates the frequency dependent nature of the motor parameters and the effects of iron loss. The stability of synchronous motor operation is studied by applying the Nyquist stability criterion to the linearized equations which describe the behavior of the motor as the motor loads perturb about a steady-state operating point. This investigation reveals that, in some cases, the stable region of the motor is delineated from the results of a computer simulation. With a view to reducing harmonic loss and improving torque pulsation from harmonic components, a very poweful pulse amplitude modulation (PAM) method using an 16-bit microcomputer has been developed. This method has the advantages of simplicity of control algorithms and requires small memory space for storing thyristor trigger angles for a three-phase PAM inverter. The method can be used for smooth control of both modulation depth and frequency over a wide range.

  • PDF