• Title/Summary/Keyword: pulse excitation

Search Result 169, Processing Time 0.028 seconds

Measurement of decoupling performance of an multi-layered underwater decoupling material (다층구조 수중 방음재의 디커플링성능 측정방법에 대한 고찰)

  • Kim, SangRyul;Kim, Jae-Seung;Kim, Jae-Ho;Ham, Il-Bae;Jeon, Jae-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.437-444
    • /
    • 2012
  • In this paper, the measurement method of the decoupling performance of a underwater decoupling material is studied. First, the simple vibro-acoustic coupled model of a multi-layered underwater decoupling material attached to a plate is analytically derived using impedance transfer matrix. Two test methods are introduced using the theoretical expression of the simple model. One is based on the ratio of the plate vibration and the radiated pressure under impact excitation of the plate. The other is based on the reciprocity theorem and uses the ratio of the incident pressure and the plate vibration under projector excitation in water. Some measurements are carried out according to the test methods using a pulse tube. The test results show the advantages and disadvantages of two methods. It is also shown that the combination of impact and projector excitation methods may be a useful tool to evaluate the performance of a underwater decoupling material.

  • PDF

Excitation Wavelength Dependence of Laser Ablation Mechanism of Urethane-Urea Copolymer Film Studied by Time-Resolved Absorbance Measurements

  • Tada, Takuji;Asahi, Tsuyoshi;Masuhara, Hiroshi;Tsuchimori, Masaaki;Watanabe, Osamu
    • Journal of Photoscience
    • /
    • v.10 no.1
    • /
    • pp.97-104
    • /
    • 2003
  • The excitation wavelength dependence of laser ablation dynamics of an azobenzene-containing urethane-urea copolymer film was investigated by measuring the laser fluence dependence of etch depth, transient absorbance change at each excitation wavelength, and transient absorption spectra. Moreover expansion/contraction dynamics was studied by applying nanosecond time-resolved interferometry. The threshold was determined at several excitation wavelengths from etch depth measurement, while time-integrated absorbance was obtained under excitation conditions. The photon energy required to remove the topmost of surface layer of the film did not .depend on excitation wavelength, and the penetration depth of excitation pulse dominated the etch depth. When the excitation wavelength was longer than 500 nm, permanent swelling was clearly observed but not for shorter wavelength excitation. In the latter case, photoisomerization occurred during excitation and the following photoreduction may play an important role. On the basis of the observations made in this study, a photochemical and photothermal mechanisms can explain mostly the short and long wavelength excitation results, respectively.

  • PDF

Optimal Excitation Angles of a Switched Reluctance Generator for Maximum Output Power

  • Thongprasri, Pairote;Kittiratsatcha, Supat
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1527-1536
    • /
    • 2014
  • This paper investigates the optimal values of turn-on and turn-off angles, and ratio of flux linkage at turn-off angle and peak phase current positions of optimal control for accomplishing maximum output power in an 8/6 Switched Reluctance Generator (8/6 SRG). Phase current waveform is analyzed to determine optimal excitation angles (optimal turn-on and turn-off angles) of the SRG for maximum output power which is applied from a nonlinear magnetization curve in terms of control variables (dc bus voltage, shaft speed, and excitation angles). The optimal excitation angles in single pulse mode of operation are proposed via the analytical model. Simulated and experimental results have verified the accuracy of the analytical model.

Alternating Acquisition Technique for Quantification of in vitro Hyperpolarized [1-13C] Pyruvate Metabolism

  • Yang, Seungwook;Lee, Joonsung;Joe, Eunhae;Lee, Hansol;Song, Ho-Taek;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.1
    • /
    • pp.53-60
    • /
    • 2016
  • Purpose: To develop a technique for quantifying the $^{13}C$-metabolites by performing frequency-selective hyperpolarized $^{13}C$ magnetic resonance spectroscopy (MRS) in vitro which combines simple spectrally-selective excitation with spectrally interleaved acquisition. Methods: Numerical simulations were performed with varying noise level and $K_p$ values to compare the quantification accuracies of the proposed and the conventional methods. For in vitro experiments, a spectrally-selective excitation scheme was enabled by narrow-band radiofrequency (RF) excitation pulse implemented into a free-induction decay chemical shift imaging (FIDCSI) sequence. Experiments with LDH / NADH enzyme mixture were performed to validate the effectiveness of the proposed acquisition method. Also, a modified two-site exchange model was formulated for metabolism kinetics quantification with the proposed method. Results: From the simulation results, significant increase of the lactate peak signal to noise ratio (PSNR) was observed. Also, the quantified $K_p$ value from the dynamic curves were more accurate in the case of the proposed acquisition method compared to the conventional non-selective excitation scheme. In vitro experiment results were in good agreement with the simulation results, also displaying increased PSNR for lactate. Fitting results using the modified two-site exchange model also showed expected results in agreement with the simulations. Conclusion: A method for accurate quantification of hyperpolarized pyruvate and the downstream product focused on in vitro experiment was described. By using a narrow-band RF excitation pulse with alternating acquisition, different resonances were selectively excited with a different flip angle for increased PSNR while the hyperpolarized magnetization of the substrate can be minimally perturbed with a low flip angle. Baseline signals from neighboring resonances can be effectively suppressed to accurately quantify the metabolism kinetics.

Dynamic response of post-tensioned rocking wall-moment frames under near-fault ground excitation

  • Feng, Ruoyu;Chen, Ying;Cui, Guozhi
    • Earthquakes and Structures
    • /
    • v.15 no.3
    • /
    • pp.243-251
    • /
    • 2018
  • The dynamic responses of a rocking wall-moment frame (RWMF) with a post-tensioned cable are investigated. The nonlinear equations of motions are developed, which can be categorized as a single-degree-of-freedom (SDOF) model. The model is validated through comparison of the rocking response of the rigid rocking wall (RRW) and displacement of the moment frame (MF) against that obtained from Finite Element analysis when subjected ground motion excitation. A comprehensive parametric analysis is carried out to determine the seismic performance factors of the RWMF systems under near-fault trigonometric pulse excitation. The horizontal displacement of the RWMF system is compared with that of MF structures without RRW, revealing the damping effect of the RRW. Frame displacement spectra excited by trigonometric pulses and recorded earthquake ground motions are constructed. The effects of pulse type, mass ratio, frame stiffness, and wall slenderness variations on the displacement spectra are presented. The paper shows that the coupling with a RRW has mixed results on suppressing the maximum displacement response of the frame.

A Measurement of Size of the Open Crack using Ultrasound Thermography (초음파 서모그라피를 이용한 개방 균열의 크기 측정)

  • Cho, Jai-Wan;Seo, Yong-Chil;Jung, Seung-Ho;Jung, Hyun-Kyu;Kim, Seung-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.3
    • /
    • pp.218-223
    • /
    • 2007
  • The dissipation of high-power ultrasonic energy at the faces of the defect causes an increase in temperature. It is resulted from localized selective heating in the vicinity of cracks because of the friction effect. In this paper the measurement of size and direction of crack using UET(Ultrasound Excitation Thermography) is described. The ultrasonic pulse energy is injected into the sample in one side. The hot spot, which is a small area around the crack tip and heated up highly, is observed. The hot spot, which is estimated as the starting point of the crack, is seen in the nearest position from the ultrasonic excitation point. Another ultrasonic pulse energy is injected into the sample in the opposite side. The hot spot, the ending point of the crack, is seen in the closest distance from the injection point also. From the calculation of the coordinates of both the first hot spot and the second hot spot observed, the size and slope of the crack is estimated. In the experiment of STS fatigue crack specimen(thickness 14mm), the size and the direction of the crack was measured.

Investigation of Changeable Discharge colour Controlled by Electronic Circuit (전자적 제어에 의한 가변색방전의 개발에 관한 연구)

  • 오철한;박덕규
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.32 no.5
    • /
    • pp.164-169
    • /
    • 1983
  • A method to control the luminous colour of a gaseous discharge tube has been investigated by using the saw-tooth wave of which rise-time was controlled by an electronic circuit. The luminous colour of a Ne - Hg lamp was changed from red to blue continuously and vice versa, and it's luminous characteristics are as follows: (a) With D.C. potentials, it showed blue colour and the relative intensity of the colour is increased first and saturated at about 17 mA as the discharge current is increased. (b) When the rise-time of the saw-tooth wave is about 10 $\mu\textrm{s}$, the red colour which is caused by Ne - excitation is dominant, and when about 200 $\mu\textrm{s}$, only the blue colour which is caused by Hg - excitation is shown. (c) With saw-tooth pulse, the relative intensity of blue is increased similarly as that with D.C. potential as the current peak of each pulse is increased, while that of red is increasing continuously and it's intensity shows about twice than blue. (d) The spectrum of red colour contains Ne - excitation lines and Hg - blue lines, but the apparent luminous colour is red because Ne - red lines are more plenty than Hg-blue lines. The spectrum of blue colour presents only Hg-blre lines.

  • PDF

A Speech Coder using the Simplified Multi-mode Method (단순화된 다중 모드 방법을 이용한 음성 부호화기)

  • 강홍구
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1995.06a
    • /
    • pp.146-149
    • /
    • 1995
  • This paper proposes a SM-CELP speech coder which applies different excitation signal according to the characteristic of speech segment at bit-rate below 4 kbps. Speech signal is divided with 2 modes such as stationary voice and etc. using the parameters of average energy of the short-time speech and the residual signal after long term prediction. Structured multi-pulse method is used for the excitation of mode-A and gaussian or pulse-like codebook for mode-B. 4.8kbps DoD-CELP are used to evaluate the performance of the proposed coder. As a result, the propose method shows 1~2 dB higher segmental signal to noise ratio and better subjectional quality without increasing the computational amount.

  • PDF

The position detecting method in SRM using pattern of phase current (SRM의 상전류 패턴을 이용한 회전자 위치 검출기법)

  • Kim, Tae-Hyoung;Lee, Dong-Hee;Ahn, Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.558-561
    • /
    • 2005
  • This paper describes a novel method of detecting excitation position in switched reluctance motor(SRM) drive. Some strategies of position sensorless control methods for the motor include the measurement of phase current and applied pulse voltage in an unexcited phase is suggested. The principle of the estimation of a rotor position is based on the detection of inductance by pulse currents. This sensorless method is very simple to detect excitation position estimation and gives efficient control of drive system. Suggested method is verified by some simulations.

  • PDF

Effect of Airgap Length Difference on the Characteristics of the Double-Sided Linear Pulse Motor (공극 길이 차이가 양측식 리니어 펄스 모터의 특성에 미치는 영향)

  • 이동주;이은웅;김성현;손홍관;김성종
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.1
    • /
    • pp.1-8
    • /
    • 2003
  • Generally, thrust force of double-sided LPM is more powerful than that of single-sided LPM. Also, double-sided LMP can be effectively applied to the high-precision position system with its simple control scheme. However, An equality between two airgap lengths Is a necessary condition for its high performance. If a little difference between two airgaps is existed, unbalanced normal force and undesirable vibration will be generated. Additionally, even though two airgap lengths are absolutely same, undesirable vibration can be generated because the direction of instantaneous normal force on mover is changed according to excitation methods. An effect of inequality of two airgap lengths is presented in this paper. Distribution of airgap permeance vs. relative displacement is analyzed by two dimensional finite element method. Excitation From this results, current waveforms to reduce the undesirable vibration is proposed.