• 제목/요약/키워드: pulse duration

검색결과 509건 처리시간 0.024초

Influences of the Irradiation of Intense Pulsed ion Beam (IPIB) on the Surface of Ni$_3$Al Base Alloy IC6

  • Le, X.Y.;Yan, S.;Zhao, W.J.;Han, B.H.;Wang, Y.G.;Xue, J.M.;Zhang, H.T.
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제6권2호
    • /
    • pp.92-96
    • /
    • 2002
  • In this paper, we treated the Ni$_3$Al based alloy samples with intense pulsed ion beams (IPIB) at the beam parameters of 250KV acceleration voltage, 100 - 200 A/cm$^2$ current density and 60 u pulse duration. We simulated the thermal-mechanical process near the surface of Ni$_3$Al based alloy with our STEIPIB codes. The surface morphology and the cross-section microstructures of samples were observed with SEM, the composition of the sample surface layer was determined by X-ray Energy Dispersive Spectrometry (XEDS) and the microstructure on the surface was observed by Transmission Electron Microscope (TEM). The results show that heating rate increases with the current density of IPIB and cooling rate reached highest value less than 150 A/cm$^2$. The irradiation of IPIB induced the segregation of Mo and adequate beam parameter can improve anti-oxidation properly of IC6 alloy. Some craters come from extraneous debris and liquid droplets, and some maybe due to the melting of the intersection region of interphase. Increasing the pulse number enlarges average size of craters and decreases number density of craters.

  • PDF

뇌자기자극을 이용한 운동신경계의 신경생리학적 평가 (Neurophysiological Evaluation of the Motor System Using Transcranial Magnetic Stimulation)

  • 신혜원;손영호
    • Annals of Clinical Neurophysiology
    • /
    • 제13권1호
    • /
    • pp.1-12
    • /
    • 2011
  • Transcranial magnetic stimulation (TMS) is a non-invasive tool used to study aspects of human brain physiology, including motor function and the pathophysiology of various brain disorders. A brief electric current passed through a magnetic coil produces a high-intensity magnetic field, which can excite or inhibit the cerebral cortex. Although various brain regions can be evaluated by TMS, most studies have focused on the motor cortex where motor evoked potentials (MEPs) are produced. Single-pulse and paired-pulse TMS can be used to measure the excitability of the motor cortex via various parameters, while repetitive TMS induces cortical plasticity via long-term potentiation or long-term depression-like mechanisms. Therefore, TMS is useful in the evaluation of physiological mechanisms of various neurological diseases, including movement disorders and epilepsy. In addition, it has diagnostic utility in spinal cord diseases, amyotrophic lateral sclerosis and demyelinating diseases. The therapeutic effects of repetitive TMS on stroke, Parkinson disease and focal hand dystonia are limited since the duration and clinical benefits seem to be temporary. New TMS techniques, which may improve clinical utility, are being developed to enhance clinical utilities in various neurological diseases.

$Ga_x(Ge_2Sb_2Te_5)_{1-x}$ (x=0, 0.05, 0.1) 박막의 물성 및 상변화 특성 평가 (A study on properties and phase change characteristics of $Ga_x(Ge_2Sb_2Te_5)_{1-x}$ (x=0, 0.05, 0.1) thin films)

  • 한광민;송기호;백승철;이현용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.103-103
    • /
    • 2009
  • 본 논문에서는 기존의 GST(GeSbTe=2:2:5)와 비교하여 상변화 재료로서의 Ga 도핑된 $Ge_2Sb_2Te_5$의 가능성을 확인하고자 하였다. 실험에 사용된 Ga 도핑된 $Ge_2Sb_2Te_5$ 박막은 전통적 melt-quenching 방법에 의해 비정질로 제작된 벌크를 Thermal evaporation을 통하여 Si(100) 및 유리 (coming glass, 7059) 기판 위에 200nm의 두께로 증착하여 제작하였다. 각 박막의 상변화 특성은 여러 온도에서 열처리된 박막을 X-ray diffraction (XRD) 측정을 통하여 확인하였다. 각 조성 박막의 비정질-결정질 상변화속도 비교를 위하여 나노-펄스 스캐너 (nano-pulse scanner)를 사용하여 power; 1~17mW, pulse duration; 10~460ns 범위에서 박막의 상변화에 따른 반사도 차이를 측정 분석하였다. Ga의 도핑농도에 따른 전기적 특성 차이를 확인하기 위하여 4-point probe를 이용하여 박막의 면 저항을 측정하였고 또한 hall 측정을 통하여 박막의 흘 계수, 흘 농도 및 이동도를 확인하고 Ga가 상전이에 미치는 영향에 대하여 분석하였다.

  • PDF

알콜 탈수소효소의 안정도에 미치는 전기 자극의 효과 (Effect of Electro-stimulation on Stability of Alcohol Dehydrogenase from Horse Liver)

  • 이강민;김철생;이혜정;함대현;박충웅
    • 동의생리병리학회지
    • /
    • 제18권6호
    • /
    • pp.1723-1727
    • /
    • 2004
  • We investigated the activity and stability of alcohol dehydrogenase from horse liver (HLADH) under the electric stimulation. The activity and stability of alcohol dehydrogenase depended on electric output voltaqe, stimulation time, pulse duration and pulse interval, and temperature. HLADH retained about 23% of its activity in buffer but 78% in 10% trehalose solution under electric stimulation with 10V, 10min, The stabilizing of enzymes against electric stimulation by stabilizing additives showed a great potential use of enzymes in biotechnology and medical engineering fields.

펨토초 레이저를 이용한 OLED 용 Shadow Mask Invar 합금의 어블레이션 (Femtosecond Pulsed Laser Ablation of OLED Shadow Mask Invar Alloy)

  • 정일영;강경호;김재도;손익부;노영철;이종민
    • 한국정밀공학회지
    • /
    • 제24권12호
    • /
    • pp.50-56
    • /
    • 2007
  • Femtosecond laser ablation of the Invar alloy and hole drilling for a shadow mask are studied. We used a regenerative amplified Ti-sapphire laser with a 1kHz repetition rate, 184fs pulse duration and 785nm wavelength. Femtosecond laser pulse was irradiated on the Invar alloy with air blowing at the condition of various laser peak power. An ablation characteristic of the Invar alloy was appeared non-linear at $125J/cm^2$ of energy fluence. For the application to a shadow mask, the hole drilling of the Invar alloy with the cross section of a trapezoidal shape was investigated. The ablated micro-holes were characterized using an atomic force microscopy(AFM). The optimal condition of hole pattern f3r a shadow mask was $4\;{\mu}m$ z-axis feed rate, 0.2mm/s circular velocity, $26.4{\mu}J$ laser peak power. With the optimal processing condition, the fine circular hole shape without burr and thermal damage was achieved. Using the femtoseocond laser system, it demonstrates excellent tool for the Invar alloy micro-hole drilling without heat effects and poor edge.

증식 치료와 근육내 자극술시의 수면 마취 (The Sedation Anesthesia for Prolotherapy and Intramuscular Stimulation)

  • 조대현;김명희;홍지희
    • The Korean Journal of Pain
    • /
    • 제19권1호
    • /
    • pp.77-80
    • /
    • 2006
  • Background: Painful experiences during procedures such as prolotherapy and intramuscular stimulation are stressful to patients and can affect the treatment outcome. We present a method for relieving pain and increasing the level of patient comfort during the procedure. Methods: Twenty six patients who requested sedation anesthesia during the procedure were examined. All patients were injected with 500 ml of 0.9% normal saline and were monitored by electrocardiography, blood pressure and pulse oximetry. The patients were supplied with oxygen (3 L/min) through a nasal cannula. Midazolam (0.02 mg/kg) and alfentanil ($8{\mu}g/kg$) was injected before the procedure and a bolus injection was administered during the procedure if patients felt any pain. The duration of the procedure, the total amount of drugs, the changes in the systolic blood pressure, heart rate, pulse oxygen saturation, sedation and pain level during procedure, satisfaction scale after the procedure, complications and the incidence of amnesia were evaluated. Results: Twenty one patients had a moderate level of sedation, 15 patients did not feel any pain during the procedure, 17 patients had high level of satisfaction (8-10). No patient experienced complications after the procedure, or unstable vital signs, and 6 patients could not remember the procedure. Conclusions: Sedation anesthesia is a safe method for relieving pain during the procedure, and most patients had a high level of satisfaction.

환경특성에 따른 안주애기박쥐(Vespertilio sinensis)의 반향정위 특징 (Characteristics of Echolocation Calls of the Parti-coloured Bat, Vespertilio sinensis, in Relation to Environment Type)

  • 정철운;한상훈
    • 한국환경과학회지
    • /
    • 제24권3호
    • /
    • pp.353-358
    • /
    • 2015
  • In this study, we analyzed two types of echolocation calls used by the parti-coloured bat, Vespertilio sinensis. Bats were captured in the Naejangsan National Park in October 2013. Call sounds of hand-released bats were recorded at the location of capture within the National Park. We analyzed pulse duration (PD), pulse interval (PI), peak frequency (PF), maximum frequency ($F_{MAX}$), minimum frequency ($F_{MIN}$), and bandwidth (BW). V. sinensis emitted the different types of the echolocation calls depending on the surrounding environment. Frequency modulated-constant frequency (FM-CF) signal of audible range was emitted when they flew in the uncluttered space over the canopy. However, when flying in the cluttered space below the canopy, they only emitted FM signal. FM-CF signal is in the audible range (e.g., low frequency), and FM signal has a harmonic broadband frequency range of two. There were significant differences in PD, PI, PF, FMAX, FMIN, and BW between the calls emitted over and below the canopy. Considering the functional characteristics of FM and CF signals, we conclude that the foraging activity of V. sinensis was observed below the canopy, and recommend the use of FM signal and broadband as echolocation signals.

300kJ${\times}$B 모듈로 구성된 커패시터 뱅크의 특성 분석 (Characteristics of Capacitor Bank Composed of Eight Paralleled Modules)

  • 성기열;정재원;최영호;김진성;추증호;이홍식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1600-1602
    • /
    • 2001
  • A pulsed power supply of 2.4MJ capacitor bank has been developed to make investigation into electric gun technology. It is made up of eight paralleled 300kJ modules, and can supply various shape of high current pulse by changing charging voltage, inductance, capacitance, and firing time of each module. The 300kJ module has been designed and fabricated for the maximum operating voltage of 22kV, peak current of 150kA, and pulse duration of 1msec. The experiments of the modules were done, and the equivalent circuit of the module was determined. The characteristics of the module were analyzed more deeply through the circuit simulation. The experiments of the paralleled modules with inductance of 20 $\mu$H and load resistance of 100 m$\Omega$ were performed, where the modules were discharged simultaneously and/or sequentially. The results of the experiments were analyzed. The 2.4MJ capacitor bank is currently used as the pulsed power supply for the ETCG (Electro Thermal Chemical Gun) research.

  • PDF

전기자극에 의한 알콜 산화효소의 활성도와 안정도연구 (Activity and Stability of Alcohol Oxidase from Hansenula sp. by Electrostimulation)

  • 이강민;김경숙;박충웅
    • 대한화학회지
    • /
    • 제48권2호
    • /
    • pp.171-176
    • /
    • 2004
  • 전기자극에서 알콜 산화효소의 활성도와 안정도를 연구하였다. 알콜 산화효소의 활성도와 안정도는 전기출력전압, 자극시간, 자극기간, 자극간격에 따라 달라진다. 전기자극에 의하여 비활성화 효소 활성도는 당, 중합체, 히드로젤과 같은 안정화 첨가제에 의하여 회복되었다. 이 효소에 전기자극을 40 V, 10분 주었을 때 완충용액에서는 활성도가 전혀 없었지만 10% 트레할로스 용액에서는 52%의 활성도를 유지하였다. 전기자극하에서 효소를 안정화시킬 수 있음은 효소를 생물공학과 의료공학에 널리 이용할 수 있는 가능성을 보여준다.

신경병증성 토끼모델에서 고전압맥동전류의 창상치유 효과 (Effects of High Voltage Pulsed Current Stimulation on the Wound Healing in Neuropathic Rabbit Model)

  • 김종만;박장성;정형재
    • 한국전문물리치료학회지
    • /
    • 제6권3호
    • /
    • pp.1-10
    • /
    • 1999
  • The purpose of this study was to determine whether high voltage pulsed current stimulation (HVPCS) would enhance wound healing in neuropathic rabbits. Ten rabbits were assigned to either an experimental or a control group. The wounded part around the peripheral neuropathy of the experimental rabbits was stimulated for two hours twice a day for six days under the following conditions: pulse frequency 80 pps, pulse duration $100{\mu}s$, and stimulation intensity 30~40 V. The results indicated that there was no difference in the wound closure between the experimental and control groups. The two groups showed similar aspects in collagen and reticulum, which were observed by colored Masson's trichome. While the rabbits in the control group had more or less thick fibers, the rabbits in the experimental group had thin and branched-shape fibers. The rabbits in the experimental group showed both strong responses in the shaping of elastic fibers and the increased aspects in fibroblast when compared with the control group.

  • PDF