• Title/Summary/Keyword: pulse duration

Search Result 509, Processing Time 0.025 seconds

Variation in Echolocation and Prey-capture Behavior of Rhinolophus ferrumequinum during Foraging Flight (관박쥐(Rhinolophus ferrumequinum)의 먹이포획 과정에 대한 행동 및 반향정위 변화)

  • Chung, Chul Un;Kim, Sung Chul;Jeon, Young Shin;Han, Sang Hoon
    • Journal of Environmental Science International
    • /
    • v.26 no.6
    • /
    • pp.779-788
    • /
    • 2017
  • In this study, we analyzed the changes in the echolocation and prey-capture behavior of the horseshoe bat Rhinolophus ferrumequinum from search phase to capture time. The experiment was conducted in an indoor free-flight room fitted with an ultra-high-speed camera. We found that the bats searched for food while hanging from a structure, and capturing was carried out using the flight membrane. In addition, it was confirmed that the mouth and uropatagium were continuously used in tandem during the capturing process. Furthermore, using Constant Frequency (CF), we confirmed that the prey catching method reflected the wing morphology and echolocation pattern of R. ferrumequinum. The echolocation analysis revealed that the pulse duration, pulse interval, peak frequency, start-FM-bandwidth, and CF duration decreased as the search phase approached the terminal phase. Detailed analysis of echolocation pulse showed that the end-FM bandwidth, which increases as it gets nearer to the capture time of prey, was closely related to the accurate grasp of the location of an insect. At the final moment of prey capture, the passive listening that stopped the divergence of the echolocation was identified; this was determined to be the process of minimizing the interruption from the echo of the echolocation call emitted from the bat itself and sound waves emitted from the prey.

Nd-YAG LASER MICRO WELDING OF STAINLESS WIRE

  • Takatugu, Masaya;Seki, Masanori;Kunimas, Takeshi;Uenishi, Keisuke;Kobayashi, Kojiro F.;Ikeda, Takeshi;Tuboi, Akihiko
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.187-192
    • /
    • 2002
  • Applicability of laser micro welding process to the fabrication of medical devices was investigated. Austenitic stainless steel wire (SUS304) was spot melted and crosswise welded, which is one of the most possible welding process for the fabrication of medical devices, by using a Nd-YAG laser. Effects of welding parameters on the microstructure, tensile strength and corrosion resistance were discussed. In the spot melting, melted metal width decreased with decreasing the input energy and pulse duration. Controlling the laser wave to reduce laser noise which occurred in the early stage of laser irradiation made reasonable welding condition wider in the welding condition of small pulse duration such as 2ms. The microstructure of the melted metal was a cellular dendrite structure and the cell size of the weld metal was about 0.5~3.5 ${\mu}{\textrm}{m}$. Tensile strength increased with the decrease of the melted metal width and reached to a maximum about 660MPa, which is comparable with that for the tempered base metal. Even by immersion test at 318K for 3600ks in quasi biological environment (0.9% NaCl), microstructure of the melted metal and tensile strength hardly changed from those for as melted material. In the crosswise welding, joints morphologies were classified into 3 types by the melting state of lower wire. Fracture load increased with input energy and melted area of lower wire, and reached to a maximum about 80N. However, when input energy was further increased and lower wire was fully melted, fracture load decreased due to the burn out of weld metal.

  • PDF

Near-Infrared Laser Stimulation of the Auditory Nerve in Guinea Pigs

  • Guan, Tian;Wang, Jian;Yang, Muqun;Zhu, Kai;Wang, Yong;Nie, Guohui
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.2
    • /
    • pp.269-275
    • /
    • 2016
  • This study has investigated the feasibility of 980-nm low-energy pulsed near-infrared laser stimulation to evoke auditory responses, as well as the effects of radiant exposure and pulse duration on auditory responses. In the experiments, a hole was drilled in the basal turn of the cochlea in guinea pigs. An optical fiber with a 980-nm pulsed infrared laser was inserted into the hole, orientating the spiral ganglion cells in the cochlea. To model deafness, the tympanic membrane was mechanically damaged. Acoustically evoked compound action potentials (ACAPs) were recorded before and after deafness, and optically evoked compound action potentials (OCAPs) were recorded after deafness. Similar spatial selectivity between optical and acoustical stimulation was found. In addition, OCAP amplitudes increased with radiant exposure, indicating a photothermal mechanism induced by optical stimulation. Furthermore, at a fixed radiant exposure, OCAP amplitudes decreased as pulse duration increased, suggesting that optical stimulation might be governed by the time duration over which the energy is delivered. Thus, the current experiments have demonstrated that a 980-nm pulsed near-infrared laser with low energy can evoke auditory neural responses similar to those evoked by acoustical stimulation. This approach could be used to develop optical cochlear implants.

Temperature Control using Peltier Element by PWM Method

  • Pang, Du-Yeol;Jeon, Won-Suk;Choi, Kwang-Hoon;Kwon, Tae-Kyu;Kim, Nam-Gyun;Lee, Seong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1400-1404
    • /
    • 2005
  • This paper presents the temperature control of aluminum plate by using Peltier element. Peltier effect is heat pumping phenomena by electric energy as one of the thermoelectric effect. So if current is charged to Peltier element, it absorbs heat from low temperature side and emits heat to high temperature side. In this experiment, Peltier element is used to control the temperature of small aluminum plate with current control and operating cooling fan only while cooling duration. Operating cooling fan only while cooling duration is proper to get more rapid heating and cooling duration. As a result of experiment, it takes about 100sec period to repeating temperature between $35^{\circ}C$ and $70^{\circ}C$ and about 80sec from $40^{\circ}C$ to $70^{\circ}C$ in ambient air temperature $25^{\circ}C$ and while operating cooling fan only in cooling duration. Future aim is to apply this temperature control method in actuating SMHA(special metal hydride actuator) which is applicable in Siver project acting in low frequency range by using Peltier element for heating and cooling.

  • PDF

Hydrologic Regimes Analyses on Down Stream Effects of the Young Chun Dam by Indicators of Hydrologic Alterations (수문변화 지표법에 의한 영천댐이 하류하천에 미치는 유황변화 분석)

  • Park, Bong-Jin;Kim, Joon-Tae;Jang, Chang-Lae;Jung, Kwan-Sue
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.2
    • /
    • pp.163-172
    • /
    • 2008
  • Hydrologic regimes play a major role in determining the biotic composition, structure, and function of river ecosystem. In this study, hydrologic regimes were analyzed on down stream effects of the Young-Chun dam construction using the Indicators of Hydrologic Alterations(IHA). The analysis results were as follows ; (1) Monthly mean flows were decreased during drought and flood season on the pre and post dam, (2) Magnitude and Duration of Annual Exterm Conditions, annual minima 1-day means was $3.48m^3/sec$, $0.89m^3/sec$ and annual maxima 1-day mean was $833.1m^3/sec$, $672.1m^3/sec$ on the pre and post dam (3) Timing of Annual Exterm conditions, Julian date of the annual minima 1-day means was 180th(June) in the pre dam, 257th(September) in the post dam, Julian date of the annual maxima 1-day means was 209th(July) in the pre dam, 217th(August) in the post dam, (4) Frequency and Duration of High and Low Pulse, Low Puls counts and duration were 3 times and 23 days in the pre dam, High Pulse counts and duration were 4 times and 2 days in the pre dam. (5) Rate and Frequency of Water Condition Changes, rise rates was 39.27 %, 19.36 % and fall rates -15.85 %, -8.16 % in the pre and post dam, respectively (6) Coefficient of Variation, annual exteram water conditions were decreased from 0.9054 to 0.6314 and from 1.0440 to 0.9617, Timing of Annual Exterm conditions were incereased for minima flow from 0.269 to 0.282, for maxima form 0.069 to 0.153.

Effect of Surface Improvement on Thin Film by In-Situ Laser Annealing Deposition (In-Situ Pulse Laser Annealing 증착에 의한 광학박막의 표면 개선 효과)

  • Lee, Se-Ho;Yu, Yeon-Serk
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.1
    • /
    • pp.34-40
    • /
    • 2009
  • In-situ pulse laser (Nd-YAG, 2nd harmonics 532 nm) annealing used in physical vapor deposition of $MgF_2$, $SiO_2$ and ZnS thin films was shown to be effective in improving their surface roughness properties. Total integrated scattering (TIS) measurements of $MgF_2$ and $SiO_2$ samples deposited on glass substrates revealed that the laser irradiation of films at an energy of approximately $140\;mJ/cm^2$ at 532 nm with a repetition frequency of 10 Hz and pulse duration of 5 ns during the deposition resulted in total scatterings that were minimum. But in case of the ZnS samples, measurements revealed minimum total scattering at a laser energy of approximately $62\;mJ/cm^2$. Atomic Force Microscopy (AFM) has been used to evaluate the effect of pulse laser annealing on the surface roughness for thin film samples. The results were similar to the TIS measurements, indicating that surface roughness was decreased when the irradiated annealing pulse laser energy increased. But it also increased when the irradiated annealing pulse laser energy was over some limit that depended on the materials.

Principles and Comparative Studies of Various Power Measurement Methods for Lithium Secondary Batteries (리튬이차전지 출력측정법의 원리 및 측정법간 비교 연구)

  • Lee, Hye-Won;Lee, Yong-Min
    • Journal of the Korean Electrochemical Society
    • /
    • v.15 no.3
    • /
    • pp.115-123
    • /
    • 2012
  • As the market of lithium secondary batteries moves from mobile IT devices to large-format electric vehicles or energy storage systems, the strengthened battery specifications such as long-term reliability longer than 10 years, pack-level safety and tough competitive price have been required. Moreover, even though high power properties should also be achieved for hybrid electric vehicles, it is not easy to measure accurate power values at various conditions. Because it is difficult to choose a proper measurement method and its experimental condition is more complex comparing to capacity measurement. In addition, the power values are very sensitive to power duration time, state-of-charge (SOC) of cells, cut-off voltages, and temperatures, whereas capacity values are not. In this paper, we introduce three kinds of power measurement methods, hybrid pulse power characterization (HPPC) suggested by US FreedomCar, so-called J-pulse by Japan electric vehicle association standards (JEVS) and constant power measurement, respectively. Moreover, with pouch-type unit cells for HEV, experimental power data are discussed in order to compare each power measurement.

Change in Rouleau Formation of Red Blood Cells by Pulse Magnetic Field Stimulus in the Hand (펄스자기장 자극에 의한 손의 적혈구 형태학적 변화)

  • Hwang, Do Guwn
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.1
    • /
    • pp.28-33
    • /
    • 2014
  • The change of rouleau formation of red blood cells in the hand stimulated by pulse magnetic field having a maximum intensity of 0.27 Tesla and pulse duration of 0.102 msec was investigated. Before pulse magnetic field stimulus, the red blood cells of test subject were adjoined over ten and the flow of cells was slowed. However after the stimulus in the hand during 10 minutes, the red blood cells adjoined over tens was spreaded out each other and its motion was fast. Also the red blood cells of left hand unstimulated by pulse magnetic field were spreaded out each other, even though the right hand was stimulated during 10 minute. It prove that the rouleau formation of red blood cells can be improve in the whole body in spite of stimulus in the hand because the blood is flowing a whole body.

Relationship between sleep duration and pulse pressure in Korean adults: Focusing on the data of the 7th National Health and Nutrition Survey (한국 성인의 수면시간과 맥압과의 관련성: 국민건강영양조사 제7기 자료를 중심으로)

  • Jung, Eun-Young
    • Journal of Digital Convergence
    • /
    • v.20 no.4
    • /
    • pp.411-418
    • /
    • 2022
  • The purpose of this study is to investigate the relationship between sleep time and pulse pressure in Korean adults, and the research method used data from the 7th period (2016-2018) of the National Health and Nutrition Examination Survey. Subjects were 5,707 persons aged 20 years or older, and for frequency and percentage continuous data, mean and standard deviation, cross analysis and independent t-test, and stepwise logistic regression analysis for high pulse pressure were performed. SPSS WIN 18.0 version statistical program was used. was used. As a result of the study, the prevalence of hypertension was higher in the overall population (OR=1.344, 95% CI=1.002-1.803) and in women (OR=1.624, 95% CI=1.112-2.371) when sleeping for more than 9 hours compared to less than 6 hours. high, but not significant in males (OR=1.012, 95% CI=0.631-1.550). Therefore, considering the effects of inappropriate sleep time on health, public health education and management are necessary. Further research on the relationship between sleep time and pulse pressure will be needed.

Change of arterial pulse wave characteristic by measurement posture and brachial blood pressure (측정 자세 및 상완 혈압에 의한 맥파 특성 변화)

  • Nam, Ki-Chang;Kim, Eun-Gun;Hoe, Hyun;Huh, Young
    • Science of Emotion and Sensibility
    • /
    • v.12 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • In this study, pulse waves were measured at radial artery using non-invasive tonometric pulse pressure measurement system, SphygmoCor(AtCor, Australia), according to subject's posture. Then it was analysed whether the pulse wave parameters, which contain heart activities, change among three different postures (upright stand, sit, and supine). And it was also verified that the pulse wave parameters change among blood pressure level groups(hypotensive, normotensive, and hypertensive). As a results, posture effects were verified in time information of pulse wave rather than amplitude. But some parameters calculated by ratio of two amplitude, such as augmented index(AI) and ratio of central aortic pulse and radial artery pulse, showed significant difference according to postures. In post hoc test, time to the $1^{st}$ and $2^{nd}$ pulse peak(P_$T_1$, and P_$T_2$), ED(ejection duration), and HR(heart rate) showed significant difference among posture groups with each other. In comparison of blood pressure groups, it was verified that the parameters related to amplitude of pulse wave showed significant difference rather than time information.

  • PDF