DOI QR코드

DOI QR Code

Change in Rouleau Formation of Red Blood Cells by Pulse Magnetic Field Stimulus in the Hand

펄스자기장 자극에 의한 손의 적혈구 형태학적 변화

  • Hwang, Do Guwn (Department of Oriental Biomedical Engineering, Sangji University)
  • 황도근 (상지대학교 한방의료공학과)
  • Received : 2013.01.02
  • Accepted : 2013.02.11
  • Published : 2014.02.28

Abstract

The change of rouleau formation of red blood cells in the hand stimulated by pulse magnetic field having a maximum intensity of 0.27 Tesla and pulse duration of 0.102 msec was investigated. Before pulse magnetic field stimulus, the red blood cells of test subject were adjoined over ten and the flow of cells was slowed. However after the stimulus in the hand during 10 minutes, the red blood cells adjoined over tens was spreaded out each other and its motion was fast. Also the red blood cells of left hand unstimulated by pulse magnetic field were spreaded out each other, even though the right hand was stimulated during 10 minute. It prove that the rouleau formation of red blood cells can be improve in the whole body in spite of stimulus in the hand because the blood is flowing a whole body.

최대 0.27 T 세기와 0.102 ms 펄스시간을 가지는 자기장 자극시스템을 이용하여 손에 인가한 후에 생혈액 분석을 통해 말초혈관에 흐르는 적혈구의 형태학적 변화를 조사하였다. 펄스자기장 자극 전 피실험자의 적혈구는 10여개 이상씩 서로 붙어있는 연전형성(連錢形成, rouleau formation)이 일어나서 적혈구의 움직임이 느려졌으나, 손에 10분간 자기장 인가한 후에 연전형성이 되었던 적혈구가 대부분 떨어져서 독립적인 움직임을 보이면서 운동이 활발해졌다. 또한 왼쪽 손에 펄스자기장을 10분 자극한 후에 자극받지 않은 오른쪽 손에서 채혈했을 때에도 연전현상이 똑같이 개선되었다. 이는 혈류흐름에 의해 체내에 모든 적혈구의 연전현상이 개선된 것으로 판단할 수 있다.

Keywords

References

  1. Jaakko Malmivuo and Robert Plonsey, Biolectromagnetism, Oxford university press (1995), chapter 1.
  2. http://en.wikipedia.org/wiki/Transcranial_magnetic_stimulation.
  3. H. N. Mayrovitz and P. B. Larsen, Wounds 4, 197 (1992).
  4. H. N. Mayrovitz and P. B. Larsen, Wounds 7, 90 (1995).
  5. D. Roland, M. Ferder, R. Kothura, T. Faierman, and B. Strauch, Plastic and Reconstructive Surgery 105, 1371 (2000).
  6. S. C. Kim, J. Korean Acupuncture Moxibustion Society 18, 23 (2001).
  7. S. W. Shin and J. S. Lee, J. Korea CHUNA Manual Medicine 2, 159 (2001).
  8. Do-Guwn Hwang, et al., "Apparatus for generating voltage for magnetic type medical instrument", Korea patent, 10-2009-0062239 (2012).
  9. J. H. Kang, J. Y. Sim, H. S. Cho, D. H Ko, S. H. Kim, and H. R. Lee, J. Kor. Acad. Fam. Med. 22, 70 (2001).
  10. The Korea Society of Hematology, "Hematology" Bummun-Education press (2011).

Cited by

  1. Comparative Analysis of Photoplethysmography under Pulsed Magnetic Field and Low Level Laser Stimulus: Motivation for Blood Flow Increase using Stimulus on Acupoint LI4 (Hegu) vol.19, pp.1, 2014, https://doi.org/10.4283/JMAG.2014.19.1.032