• Title/Summary/Keyword: pulse cycle

Search Result 312, Processing Time 0.034 seconds

Study on Nickel Plating of Leadframe using Pulse Technique (펄스법을 이용한 리드프레임의 니켈도금에 관한 연구)

  • Chung W.S.;Min B.S.;Lim J.J.;Chung U.C.
    • Journal of the Korean institute of surface engineering
    • /
    • v.36 no.3
    • /
    • pp.242-250
    • /
    • 2003
  • Electrodeposition of Ni was carried out on copper substrate from Ni Sulfamate bath by DC and high frequency pulse current. During the electroplating, bath temperature was steady $60^{\circ}C$ , agitation was applied. Morphology and surface roughness of electrodeposits was investigated with the AFM. Crystalline structure of electrodeposits was investigated with XRD. Also, surface electric resistivity was investigated with 4-point probe. The result of crystalline structure by X-ray diffractometer, in the case of DC, <200> direction was dominant growing direction. But in the case of PC, the ratio of <200> direction vs. other direction decreased. As the pulse frequency increased, the enhanced properties of deposits were shown. With increasing frequency, the degree of surface properties increased DC more than that of PC, eg surface morphology, roughness and the degree of compactness of grains. With increasing duty cycle, the surface properties such as the degree of the morphology, roughness and electroconductivity was deteriorated.

Electrical characteristics and pulse memory operation of 3-electrode DC-PDP (3전극 직류형 PDP의 전기적 특성과 펄스 메모리 구동)

  • 명대진;손일헌
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.7
    • /
    • pp.32-39
    • /
    • 1998
  • This paper presents the experimental results on the 3-electrode DC-PDP which has a common electrode to improve the PDP life cycle. The measured DC characteristic proves the effectiveness of common electrode absorbing about half of discharge currents. The waveforms for pulse memory operation of3-electrode PDP without crosstalk could also be determined from the I-V characteristics. The pulse memory drives of 8*8 cell array show the frequency response fo memory margin and the luminance efficiency of 3-electrode PDP are quite different from genrally known characteristics of 2-electrode DC-PDP.

  • PDF

Development of Low Frequency Pulse MIG Welding Process for AL and its alloy (AL 및 AL합금의 저주파 PULSE MIG 용접법의 개발)

  • 최병길;이사영;이승학;천성진
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.45-48
    • /
    • 1997
  • The low frequency pulsed MIG welding process of new current waveform control to switch over unit pulse conditions (pulse current, pulse duration) in the fixed cycle was developed and its effect were investigated for aluminium and its alloy. By using this new welding process, the bead appearance having clear ripple pattern, such as TIG welding bead can be obtained and the gap tolerance of lap and butt welding joint can be expanded.

  • PDF

A study on non-invasive SaO$_2$ measurement algorithm to improve on effect of the motion artifact (동잡음의 영향을 개선한 비관혈식 산소포화도 측정 알고리즘에 대한 연구)

  • 이준하
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.101-107
    • /
    • 2000
  • Pulse oximetry is a non-invasive optical method which measures arterial oxygen saturation with two different wavelength. We can obtain the pulsating component of the arterial blood superimposed on DC level attenuated by venous blood, skin and other nonpulsatile components. This study is based on computing algorithm of oxygen saturation using the integral ratio of pulsatile components. In this algorithm, we used the half cycle of the pulsatile signal rely on arterial contraction. It's period is about 1/4 in 1 cycle. In the result, Our algorithm with 1/4 period of 1 cycle is similar to existing model. Because of removal that A part have low amplitude and possession in long term from calculating, the effect of the motion-artifact is decrease.

  • PDF

Characteristics and Preparation of Manganese Oxide Electrode by Using Pulse Voltammetry Electrodeposition for Electrolysis (펄스 전착법을 이용한 전기분해용 망간 산화물 전극의 제조 및 특성)

  • Yang, Jeong-Jin;Lee, Mi-Young;Kim, Jeong-Sik;Shin, Hyun-Soo;Park, Soo-Gil
    • Journal of the Korean Electrochemical Society
    • /
    • v.13 no.2
    • /
    • pp.138-144
    • /
    • 2010
  • In order to investigate the electrochemical propertied of titanium electrode for electrolysis, manganese oxide was electrodeposited on surface of mesh titanium by pulse voltammetry. The morphological changes and impedance results of manganese oxide electrodeposited electrode were analyzed by SEM and EDX. The size of electrodeposited manganese oxide on mesh titanium was increased with first cycle pulse time increase, and approximately 100 non-uniform manganese oxide was grown at 10 ms pulse polarization time. Charge transfer resistance($R_{ct}$) of near the overpotential was analyzed by EIS measurement and the feasibility of prepared electrode was evaluated by the overpotential calculated from Tafel plots.

A study on the pulse forming of pulsed $CO_2$ laser using active multi-pulse superposition (능동적 다중 펄스 중첩법(AMPS)을 적용한 펄스형 $CO_2$ 레이저의 펄스 성형에 대한 연구)

  • Chung, Hyun-Ju;Park, Sung-Joon;Jung, Yong-Ho;Song, Gun-Ju;Kim, Hee-Je;Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1631-1633
    • /
    • 2001
  • In manufacturing processes, various and suitable pulse shapes are required for the purpose of material processing and the pulseshape is regarded as a dominant factor due to the specific property of processing materials. Therefore, in this study, a variable pulse width, high duty cycle Pulse Forming Network(PFN) is constructed by time sequently. The power supply for this experiment consists of three switching circuits. The PFN elements operate at low voltage and drive the primary of HV leakage transformer. The secondary of the transformer has a full-wave rectifier, which passes the pulse energy to the load in a continuous sequence of properly phased and nested increments. We investigated laser pulse width as various delay time among three switching circuit. As a result, we tan obtain various laser pulse width from about 4ms to 10ms. The maximum laser pulse width obtained at this experiment was about 10ms at delay time of 4ms among each switching circuit.

  • PDF

Effect of pulse-wave factors in Middle Aged Women by Mountain Cultivated Ginseng Pharmacopuncture Original Articles (산삼 약침이 정상 중년여성의 맥파요인에 미치는 영향)

  • Park, Sang-Wook;Kim, Yi-Soon;Hwang, Won-Deok;Kim, Gyeong-Cheol
    • Journal of Pharmacopuncture
    • /
    • v.14 no.1
    • /
    • pp.35-49
    • /
    • 2011
  • Objectives: The aim of this experiment is to know about Effect of pulse-wave factors in Middle Aged Women by Mountain Cultivated Ginseng Pharmacopuncture. Methods: First 20 Middle Aged women are diagnosed by pulse diagnosis, and then Mountain Cultivated Ginseng Pharmacopuncture(1 injection 20cc) were injected. 30 minutes later, pulse diagnosis again performed. As a result, method of one-group pretest-posttes design were used for evaluation. Results: T(Total pulse cycle) time statistically significant increased on both left and right chon, kwan, cheok. T4 time statistically significant increased on both left and right chon, kwan, cheok. T4-T1/T indexs except left cheokmaek, Right cheokmaek observation area decreased significantly in four sites. Wm(indicating high pressure retention time) indexs increased significantly in the five sites were observed except right chon maek. Conclusions: Effect of pulse-wave factors in Middle Aged Women by Mountain Cultivated Ginseng Pharmacopuncture increased T, T4, Wm and decreased T4-T1/T indexs. The results of this experiment, Mountain Cultivated Ginseng Pharmacopuncture induced to increase the Pulse-wave's stability and strength.

The Analysis on the Reliability of Measuring Pulse-Respiration Ratio (맥솔(脈率) 측정방법(測定方法)의 신뢰도(信賴度) 분석(分析))

  • Kim, Dong-Hoon;Yang, Dong-Hoon;Huh, Woong;Park, Young-Jae;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.9 no.2
    • /
    • pp.123-144
    • /
    • 2005
  • Objectives: Pulse-Respiration Ratio has been used for estimating subject's Han-Yeol [寒熱] status since it mentioned in suwen [素問]. In practicing Pulse-Respiration Ratio over 5 means the status of Yeol [熱], Pulse-Respiration Ratio below 3 means the status of Han [寒]. We performed this study to examine the Optimum Standard for Measuring Pulse-Respiration Ratio on the Basis of Repeatability and Reproducibility. Methods: After subject's 5 minutes rest we measured subject's ECG, respiration pattern, EEG, EMG simultaneously. In this research examiner's number is two, subject's number is four, and the number of repeat is two. We calculated Pulse-Respiration Ratio through dividing Respiration cycle average by Pulse cycle average according to each standard including time section, $EEG(relative-{\alpha}$ density, $relative-{\beta}$ density, ${\alpha}/{\beta}$ and EMG. We analyzed these data through Gage R&R study using MINITAB 13.20 program and considered the results of below 30 %R&R and over 4 Number of Distinct Categories to have a significance. Results: 1. In the applying of time standard, Pulse-Respiration Ratio from section 3, 4, 6, 8 had a significant meaning in the aspect of Repeatability and Reproducibility. 2. In the applying of $EEG({\alpha}$ I , ${\beta}$ I , ${\alpha}/{\beta})$, EMG(E I) standard, there was no significant results. 3. In the applying of time standard(section 5, 6, 7), $EEG({\alpha}$ I , ${\beta}$ I , ${\alpha}/{\beta})$ and EMG(E I) standard simultaneously, Pulse-Respiration Ratio from ${\alpha}/{\beta}$ in section 6, ${\beta}$ I in section 8 had a significant meaning in the aspect of Repeatability and Reproducibility. Conclusions: We can suggest the Optimum Standard for Measuring Pulse-Respiration Ratio on the basis of Repeatability and Reproducibility as followings; 1. Pulse-Respiration Ratio Measuring time should be at least 15 minutes. 2. Applying of time(section 6, 8) and $EEG({\beta}$ I, ${\alpha}/{\beta})$ standard simultaneously is recommended considering reliability and validity but more study is needed. 3. EMG(E I) may be helpful to detect the segment of physical rest and exclude artifacts but more study is needed.

  • PDF

Effect of Pulse and Pulse-Reverse Current on Surface Morphology and Resistivity of Electrodeposited Copper (정펄스 및 역펄스 방법을 이용하여 구리 전해도금 시 전착층의 표면 형상과 고유저항에 미치는 효과)

  • Woo, Tae-Gyu;Park, Il-Song;Seol, Kyeong-Won
    • Korean Journal of Materials Research
    • /
    • v.17 no.1
    • /
    • pp.56-59
    • /
    • 2007
  • Recently, requirement for the ultra thin copper foil increases with smaller and miniaturized electronic components. In this study, we evaluated the surface morphology, crystal phase ana surface roughness of the copper film electrodeposited by pulse method without using additives. Homogeneous and dense copper crystals were formed on the titanium substrate, and the optimum condition was 25% duty cycle. Moreover, the surface roughness(Ra), $0.295{\mu}m$, is the smallest value in this condition. It is thought that this copper foil is good for electromigration inhibition due to the preferential crystal growth of Cu (111)

Densification of Carbon/Carbon Composites by Pulse CVI with and without Residence (펄스화학기상침트법에 의한 탄소/탄소 복합재료의 치밀화에 있어서 가스유지시간 유무의 영향)

  • 이용근;류호진;박희동
    • Journal of the Korean Ceramic Society
    • /
    • v.33 no.8
    • /
    • pp.935-941
    • /
    • 1996
  • Two-dimensional carbon/carbon preforms made of PAN-based carbon yarn and phenolic resin were densified with pyrolysis of propane by pulse chemical vapor infiltration where repeated the cycle of gas introduction residence and evacuation. Maximim density increment was 14% when infiltration temperature and time were 100$0^{\circ}C$ and 21.25 hrs respectively. The distribution of deposits of pyrocarbon by this process has been occurred uniformly in the bottom middle and top of carbon/carbon composite preform Pulse CVI with residence is most effective in increasing density and shortening infiltration time among isothermal CVI and pulse CVI with and without residence.

  • PDF