• 제목/요약/키워드: pulse corona

검색결과 108건 처리시간 0.028초

고효율 오존생기용 고주파 공진형 인버터의 특성 해석 (Analysis of high-frequency resonant Inverter character using efficient ozonizer)

  • 김영훈;황영민;노인배;김영빈;허태원;우정인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.246-248
    • /
    • 2002
  • This paper presents a high-frequency voltage source inverter for silent corona discharge ozonizer application, which is characterized by the power control based on pulse density modulation (PDM). The PDM inverter produces either a square -wave ac-voltage state or a zero-voltage state at its ac terminals to control the average output voltage under constant do voltage and operating frequency. This results in a wide range of power control in the silent corona discharge load with a strong nonlinear characteristics. And proposed addition circuit for maintain discharge on the center of the airgap. In this paper, schemed equivalent electric circuit of the discharge electrode for simulation. Finally, the effectiveness of this discharge tube character of silent corona ozonizer is investigated in the simulation results.

  • PDF

광학렌즈 AR 코팅에 따른 폴리머애자에서의 방전 자외선 강도 비교 (Comparison of Discharge UV Intensity Due to AR Coating of Optic Lens on Polymer Insulator)

  • 김영석;송길목;방선배;김종민;최명일
    • 조명전기설비학회논문지
    • /
    • 제26권4호
    • /
    • pp.35-40
    • /
    • 2012
  • In this study, the ultraviolet (UV) intensity of polymer insulator was measured using the Anti-Reflective (AR) coating lens on the occurrence of corona discharge. The UV intensity was compared before and after the AR coating. Under the 200-260[nm] of UV lens, the reflection rate before AR coating was 7.5~5.5[%] with 85-89[%] of transmission rate. After AR coating, however, the reflection rate decreased to 1.3~1.22[%] with improved transmission (97.4~97.6[%]). Then, the UV intensity by distance was measured in the polymer insulator. According to the measurement, the UV intensity increased 6.5 times at 37.5[%] of Vm/Vbd with 5[m] of distance. As distance increased, the growth rate declined. As high voltage increased, in addition, AR coating was less effective due to the count error caused by the UV sensor pulse signal overlap. Therefore, it appears that it would be more effective to detect corona discharge with 5[m] or less of distance at diagnosis of power facilities by AR coating and UV sensor sensitivity.

Pulse-Sequence Analysis of Discharges in Air, Liquid and Solid Insulating Materials

  • Suwayno, Suwayno;Mizutani, Teruyoshi
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권4호
    • /
    • pp.528-533
    • /
    • 2006
  • Electrical discharges may occur in gas, liquid as well as solid insulating materials. This paper describes the investigation results on the discharges in air, silicone oil and low density polyethylene (LDPE) using needle plane electrode system under AC voltage of 50 Hz. The experimental results showed that for discharge in air (corona), discharge pulses were concentrated around the peak of applied voltage at negative half cycle. For silicone oil positive as well as negative discharges were observed which concentrated around the peak of applied voltage. The positive pulse number was smaller but the magnitude was higher than that of negative discharge. Discharges in void took place at wider range of phase of applied voltage. The unbalance in pulse number and magnitude similar to that of oil discharges were observed. For electrical treeing in LDPE, the discharges were spread before the zero cross of the applied voltage up to the peak at both positive and negative half cycles. The discharge pulse sequence analysis indicated that the PD occurrence in air, oil and void were strongly affected by the magnitude of applied voltage. However, for electrical treeing it was observed that the discharge occurrence was strongly affected by the time derivative of the applied voltage (dv/dt).

다중도선 코로나 선전리형 TEA $CO_2$ 레이저 증폭기의 증폭특성 (Amplification Characteristics of Multiple-Wire Corona Preionization type TEA $CO_2$ Laser)

  • 임창문
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1990년도 제5회 파동 및 레이저 학술발표회 5th Conference on Waves and lasers 논문집 - 한국광학회
    • /
    • pp.59-63
    • /
    • 1990
  • Two-stage TEA(transversely excited atmospheric pressure) CO2 laser amplifier system, Amp I and Amp II are consturcted and their amplification characteristics are investigated theoretically and experimentally. Multiple-wire corona preionization method is used for uniform discharge in laser oscillator and amplifiers. At optimumm gas ratio, CO2 : N2 : He = 1 : 1 : 3, output pulse energy of the oscillator is 0.4J and finally two-stage amplification gives 1.5J output energy which is larger than pumping threshold of para-H2 Raman laser. The rate equations of the amplifiers are solved numerically, and the results are compared with the experimental results. In conclusion, the small signal gain cocfficient of AMP I is 0.025/cm and that of AMP II is 0.02/cm.

  • PDF

저온 플라즈마 공정용 펄스발생 전원장치의 성능시험 (Test Results of Pulsed Power Supply for Nonthermal Plasma Process)

  • 장성덕;변영철;조무현;신동남
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1574-1575
    • /
    • 2011
  • The application of a pulsed power system is being extended to an environmental and industrial field. The non-destructive gaseous pollutants from industrial plants such as power generation plants and incinerators can be processed by applying high voltage pulses with a fast rising time (a few nanoseconds) and short duration (nano to microseconds) in a pulsed corona discharge reactor. The pulsed plasma generator with a triggered switch has been developed. Its corona current in load can be adjusted by applied voltage and repetition rate. We investigated the performance of the pulsed plasma generator by analyzing the concentration of ozone in small reactor. This paper describes the electrical characteristics of the pulse generator with a voltage of 30 kV at repetition rate of 50 PPS. In addition, we briefly discuss a configuration of the system and initial test results.

  • PDF

고성능 멜트블로운 부직포 복합필터 개발 (Development of composite filter with high performance meltblown non-woven)

  • 이재달;홍영기;배기서
    • 한국염색가공학회지
    • /
    • 제17권2호
    • /
    • pp.40-45
    • /
    • 2005
  • Electret filter is good enough to protect health and environment from air pollution. The reason why is gathering particles not only by mechanical mechanism but also by electrostatic attraction. Especially this filter is shown lower pressure drop than general mechanical filters as glass fiber. For making electret filter media using polypropylene meltblown(M/B) nonwoven, the nonwoven is charged with corona which was supplied high voltage DC, AC, and pulse with DC power. The electret filter media is tested with $0.3{\mu}m$ sodium chloride and dioctyl phthalate(DOP) aerosol. Results revealed that filtration performance of electret filter media increased as corona was applied with higher voltage and with AC power rather than DC, and fiber diameter was fine and uniform.

온라인 변압기 부분방전 측정기법 적용 (An Application of the On Line Partial Discharge Measurement Method in Transformer)

  • 권동진
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권8호
    • /
    • pp.394-400
    • /
    • 2001
  • This paper describes an application of the on line partial discharge measurement method in operating transformer. In the operating transformer, the partial discharge signal may be superimposed by radio intereference voltage(RIV) and pulse shaped noise signals generated by external corona. The partial discharge quantity showed about 3,800pC due to very high sinusoidal interferences at the measuring impedance terminal of the transformer bushing tap. In order to reject these noises, this paper applied RIV filter, band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,800pC to 160pC.

  • PDF

코로나 카메라를 이용한 불량애자 검출사례 분석 (Analysis on the Degradation of Insulators using Corona Camera)

  • 김호수;김필환;유영각;구경완;김효진;김대식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.132-134
    • /
    • 2003
  • Insulator that is used in electric power equipment superannuation and being damaged disorder can. Such as defected insulator has repair or change must because defective influence in electrical equipment. There are many method developed for detecting the defected insulators, analyzed various test of devide voltage, electric field, ultrasonic and discharge pulse. But methods of detecting ultrasonic of discharge, electric field or leakage current could not application in the field, In this paper, we compare the advantage and the limitation of the method to detect defected insulator, and wish proposed using corona camera.

  • PDF

펄스 스트리머 방전을 이용한 NOx 제거 (Removal of NOx by Pulsed Streamer discharge)

  • 고희석;박재윤;김건호
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권8호
    • /
    • pp.807-811
    • /
    • 1997
  • In this paper we have investigated the removal characteristics of NOx by pulsed corona discharge with a multi-pointplane electrode where a magnetic field is applied in the discharge region. The efficiency of NOx removal was measured and analyzed as a function of pulse frequency gas flow rate NOx initial concentration magnetic flux density. In this result the highest removal efficiency of NOx was obtained at the following operating conditions; the frequency =400[Hz] gas flow =1[$\ell$/min] initial concentration= 400[ppm] and magnetic flux density=0.36[T].

  • PDF

PPCP에 의한 연소가스 중 NOx, SOx 동시제거 특성 (Simultaneous Removal Characteristics of NOx, SOx from Combustion Gases using Pulse Corona induced Plasma Chemical Processing)

  • 박재윤;고용술;정장근;김정달
    • 대한환경공학회지
    • /
    • 제22권2호
    • /
    • pp.211-216
    • /
    • 2000
  • 본 연구는 오염가스 제거시 발생되는 부산물인 에어로졸 입자가 방전전극에 부착되어 생기는 방전불안으로 제거율이 급격히 저하되는 문제점을 개선하고 제거장치의 운전비용을 감소시키기 위한 연구이다. 이를 위해 오염가스 제거에 필요한 라디칼과 이온을 발생시키기 위한 전기방전영역과 연소가스가 흐르는 관로를 분리시킨 플라즈마 반응기를 사용하여 방전불안에 의한 제거효율 저하와 방전선 산회 문제를 개선하여 장시간 운전 가능성을 확인하였고, 또한 운전비용을 감소시키기 위해서는 코로나 방전에 의한 비열플라즈마를 이용하여 연소가스를 산화 변화시키고, 첨가제로 수산화나트륨 수용액 증기와 소량의 암모니아를 사용하였다. 그 결과 암모니아 분자 몰비를 1.5로 하고, 유량이 $2.5{\ell}/min$인 질소가스로 농도가 20%인 수산화나트륨 수용액을 버블링하여 주입하였을 때 질소산화물, 황산화물 제거율이 각각 95, 100%인 우수한 제거특성을 얻었다.

  • PDF