• Title/Summary/Keyword: pullout capacity

Search Result 119, Processing Time 0.026 seconds

Characteristics of Pullout Behavior of Soil Improvement(SI) Anchor (지반개량(SI)앵커의 인발거동특성)

  • 임종철;홍석우;송무효;강낙안
    • Geotechnical Engineering
    • /
    • v.14 no.6
    • /
    • pp.139-151
    • /
    • 1998
  • SI anchor means the soil improvement anchor. The ground for supporting anchor is improved by JSP, and as a result, SI anchor body has about 80cm in diameter. SI anchor shows high pullout resistance by the frictional force between anchor body and ground, and the bearing capacity of anchor body. Especially the frictional force increases very much with increasing diameter of anchor body improved by JBP. In this study, model and field tests are made to analyse the mechanism of pullout resistance of SI anchor. Through model tests for the SI anchor in air dried sandy ground, strain fields of ground around SI anchor surface are analysed by a photo analysis method using the latex membrane on the wall of soil tank. The results of field tests are analysed by the strains measured by 10 strain gages attached on the inner wall of specially designed PVC pipe embedded in anchor body, and the strains of anchor body are also measured in the model tests.

  • PDF

Effects of harsh environmental exposures on the bond capacity between concrete and GFRP reinforcing bars

  • Al-Tamimia, Adil;Abed, Farid H.;Al-Rahmani, Abdulla
    • Advances in concrete construction
    • /
    • v.2 no.1
    • /
    • pp.1-11
    • /
    • 2014
  • This paper demonstrates an experimental study to evaluate the effects of environmental exposures on the bond between ribbed Glass Fiber Reinforced Polymer (GFRP) reinforcing bars and concrete. The equation recommended by ACI 440-1R-06, for the bond stress,was evaluated in this study. A total of 16 pullout samples, 12with GFRP bars and 4with steel bars, were exposed to two different harsh environments for different periods of time. The exposed harsh environments included direct sun exposure and cyclic splash zone sea water. The variation in the shear (bond) strengths before and after exposure was considered as a measure of the durability of the bond between GFRP bars and concrete.Experimental results showed there is no significant difference of the bond strength between 60 and 90 days of exposures.It also showed that the empirical equation of the bond stress calculated by ACI 440-IR-06 is very conservative.

Creep of Plate Anchors Embedded in Bentonite (Bentonite에 근입된 앵커의 Creep 특성)

  • Shin, B.W.;Lee, J.D.;Shin, J.H.;Lee, B.J.
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.4
    • /
    • pp.3-8
    • /
    • 1995
  • Anchors find their use in providing tie-back resistance for submerged footings, transmission towers, tunnels and ocean structures. Laboratory model teats were performed for the short-term net ultimate uplift capacity of a circular anchors with respect to various embedment depths and moisture content in saturated bentonite. The tests have been conducted with the anchor at two different moisture contents. Based an the model test results, empirical relationships between the net load, rate of strain, and time have been developed. Test results are as follows. 1) In creep tests for load versus ultimate uplift capacity, the displacement of plate anchors rapidly increases during the primary stage but thereafter becomes constant over a period of time. 2) Displacement increased with the increase of the sustain load and embedded ratio in soil. 3) If the load is less than or equal to 75% of the short-term ultimate uplift capacity, a complete pullout does not occur due to creep.

  • PDF

Fracture Behaviors of Headed Bars with Different Plate Types (플레이트 형상에 따른 Headed Bars의 파괴거동에 관한 연구)

  • 박현규;윤영수;류영섭;이만섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.935-940
    • /
    • 2002
  • This paper presents the failure mode on Headed Bars and prediction of tensile capacity, which is governed by concrete cone failure. 17 different plate types, three different concrete strengths and three different welding types of specimens were simulated. Static tensile load was applied Headed Bars were manufactured in different areas, and their shape and thickness are based on ASTM 970-98. Calculation of embedment length in concrete is conducted based on CSA 23.3-94, and static tensile load was applied. Tested pullout capacities were compared to the values determined using current design methods such as ACI-349 and CCD method.

  • PDF

Pullout Capacity of Ground Anchors in Weathered Soil (풍화토 지반에 설치된 앵커의 인발 특성)

  • 김낙경
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.4
    • /
    • pp.231-239
    • /
    • 2001
  • 건설 현장에서 널리 사용되고 있는 그라운드 앵커의 거동 특성을 연구하기 위하여 계측기를 부착한 일곱 개의 그라운드 앵커를 국내에 널리 분포되어 있는 화강 풍화토 지반인 $\bigcirc$$\bigcirc$$\bigcirc$대학교 지반 시험장에 설치하여 인발 시험을 수행하였다. 저압 그라우트 인장형 앵커 3개와 압축형 앵커 4개를 시험하였고, 시험은 AASHTO 규정에 의거한 인발시험, 크리프시험, 장기거동시험을 수행하였다. 시험 결과로부터 화강 풍화토 지반에 설치된 저압그라우트 직선형 앵커의 지반과의 마찰계수, 크리프 변형율, 하중감소 특성을 평가하였다.

  • PDF

Pullout Characteristics of Reinforcing Body Using Pressure Re-injection Grouting Method (압력재주입 그라우팅 방식을 이용한 보강재의 인발특성)

  • Lee, Bongjik;Kim, Sangsu;Youn, Junsik;Lee, Jongkyu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.10
    • /
    • pp.25-31
    • /
    • 2010
  • Anchor, soil nail, micropile have been widely used for slope reinforcement and foundation. These all methods need grouting work after placing reinforcing member. In domestic case, gravity fill techniques and pressure grouting techniques are mainly used. In contrast the pressure re-injection grouting method is not commonly used because grouting equipment and lack of practical application example is short and the verification of reinforcing effect is difficult. Pressure re-injection grouting is a kind of post grouting which technique increases the radial stresses acting on the grout body and causes irregular surface to be developed around bond length that tends to interlock the grout and the ground. In this study, the field test was performed to evaluate the reinforcing effect with the variation of grouting methods and pullout characteristics of reinforcing member placed by pressure re-injection grouting method. The test results showed that the post-grouting methods were useful to increase the pullout capacity.

Expansion Ratio of Pulse Power Underreamed Anchor (펄스방전 그라운드 앵커의 확공 특성에 관한 연구)

  • Kim, Nak-Kyung;Ju, Yonh-Sun;Kim, Sung-Kyu;Seo, Hyo-Kyun;Kim, Sun-Ju
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.1107-1112
    • /
    • 2009
  • Ground anchor should not be used in soft clay, because anchor resistance can not be guaranteed. However, there is a way to increase the capacity of anchors. The pulse powered anchor is an underreamed anchor by using high voltage electrokinetic pulse energy. In this study, a series of field test were carried out in order to find expansion rate related in number of pulse charge. and Anchor pull-out tests were performed at the Geotechnical Experimentation Site at Sungkyunkwan University in Suwon, Korea. Data were analyzed in order to define a relation between expansion rate and ultimate pullout load.

  • PDF

A Study on the Resistance Spot Weldability of 590 MPa Grade DP Steel with Modified Electrode Tip (가공 전극을 적용한 590 MPa급 DP강의 저항 점용접에 관한 연구)

  • Lee, Sang-Min;Park, Yeong-Do
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.1
    • /
    • pp.71-76
    • /
    • 2010
  • The use of advanced high-strength steels (AHSS) in automotive applications has steadily increased over the past few years. Two different failure modes are generally observed in shear-tension tests for resistance spot welds of AHSS. interfacial fractures and full button pullout. Despite high load-carrying capacity. the resistance spot welds in AHSS cue prone to interfacial fractures. To improve the load carrying ability of welds during shear-lap and cross tension tests. the tip surface of the electrode was grooved in a round shape. The electrode tip surface was modified so as to concentrate the current now in the central and circumferential portion of the electrode force. The results showed that the interfacial fracture was suppressed in welds using the modified electrode. In a comparison of failure mode during mechanical tests. the welds made with the modified electrode showed a higher tendency to fail via full button pullout fracture.

Fracture Behavior of CIP Anchor in Cracked Concrete (균열 콘크리트 면에서의 CIP앵커의 파괴거동)

  • 김호섭;윤영수;윤영수;박성균
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.169-174
    • /
    • 2001
  • This study concerns crack effect on concrete anchor system and prediction of tensile capacity, as governed by concrete cone failure, of single anchors located at center of concrete specimen. To Investigate crack effect three different types of crack such as crack width of 0.2mm and 0.5nm, crack depth of loom and 20cm, and crack location of center and biased point were simulated. The static tensile load was subjected to 7/8 in. CIP anchor embedded in concrete of strength 280kg/$cm^{2}$. Tested pullout capacity was compared to prediction value by each current design method (such as ACI 349-97, ACI 349 revision and CEB-FIP which is based on CC Method), In these comparison CC Method and ACI revision showed almost same value in uncracked concrete specimen, however in cracked concrete CC Method showed conservativeness. Therefore the design by ACI 349 revision is recommended for the safe and economic design.

  • PDF