• Title/Summary/Keyword: protective systems

Search Result 499, Processing Time 0.027 seconds

A Development of Protective Relay Operating-Diagnosis System for Power System (송전계통 선로보호 계전기 동작 진단 시스템)

  • Kim, K.J.;Lee, S.J.;Choi, M.S.;Kang, S.H.;Kim, H.P.;Lee, W.H.;Choi, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.107-109
    • /
    • 1999
  • In the point of view protective relay, the selectivity and sensitivity is very important in its performance. The correct setting of the relay parameter is required. The verification of accurate setting for the protective relay is very difficult before a actual fault occurs. In this paper, we proposed the diagnosis expert system as a method to verify the correctness of the relay setting. The developed system proved effectiveness through the tests on the real systems.

  • PDF

Development of SFCL Model using RTDS (RTDS 초전도한류기 해석모델 개발)

  • Lee, Seung-Ryul;Kwon, Jung-Ji;Yoon, Jae-Young;Lee, Byong-Jun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.10 no.3
    • /
    • pp.9-13
    • /
    • 2008
  • It is very important to study the protective relaying system from the viewpoint of technical analysis to apply superconducting power devices to real power systems. In this paper, we developed Superconducting Fault Current Limiter (SFCL) analysis model using Real Time Digital Simulator(RTDS) for protective relay tests in power system with SFCLs. The RTDS model has the operation mechanism of a real SFCL system.

AN EXPERT SYSTEM FOR SETTING AND COORDINATION OF PROTECTIVE RELAYS (보호계전기의 정정 협조 전문가 시스템)

  • Lee, Seung-Jae;Kim, Ki-Hwa;Cho, Young-Ik;Yoon, Sang-Hyun;Yoon, Man-Chul;Lee, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.358-362
    • /
    • 1991
  • This paper describes enhancements made on PROSET, an, expert system which can perform setting and coordination of protective relays used in the ultra-high voltage transmission systems. Enhancements include the friendly and convenient environment for rulebase management and system manipulation, expanded setting capability, and faster processing speed which have been achieved through adoption of the new rule representation, rule order independent IE, rulebase editor, local database generator, Interface to PSS/E fault program, RB expansion etc.

  • PDF

Survey of Damage Cases for Surge Protective Devices Installed Electrical Communication Systems and Analysis of Degradation Diagnosis Method (전자통신설비의 SPD 소손사례 및 열화진단기법 분석)

  • Lim, Jong-Wook;Lee, Jae-Young;Kwon, June-Hyuk
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.15-18
    • /
    • 2009
  • In recent years electric devices and telecommunication facilities were often damaged by surge generated lightning discharge. When the service was interrupted by failure of electrical devices due to surge the social loss is very enormous. Therefore in order to protect electrical systems against lightning, SPDs(Surge protective device) have been used But damaged SPDs often make some troubles like fire and interrupt of service. In this work, 3rd harmonic leakage current defection method was applied as the diagnosis of SPD degradation and the effectiveness of this method was verified by field survey.

  • PDF

Fuzzy Logic Based Relaying Using Flux-differential Current Derivative Cure for Power Transformer Protection

  • Kwon, Myoung-Hyun;Park, Chul-Won;Suh, Hee-Seok;Lee, Bock-Gu;Shin, Myong-Chul
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.8 no.5
    • /
    • pp.72-82
    • /
    • 1998
  • Power transformer protective relay should block the tripping during magnetizing imrush and rapidly operate the tripping during internal faults. But traditional approaches maloperate in the case of magnetizing inrush with low second harmonic component and internal faults with high second harmounic component. To enhance the fault detection sensitivities of conventional technuques, flux-differential current derivative curve by fuzzy theory approaches is used. This paper deals with fuzzy logic based protective relaying for power transformer. The proposed fuzzy based relaying algorithm consisits of flux-differential current derivative curve, harmonics restraint, and precentage differential characteristic curv. The proposed relaying was tested with relaying signals obtained from Salford EMTP simulation package and showed a fast and accurate trip operation.

  • PDF

An Object Based Graphical Simulator for Power System Protection (객체지향 송전계통보호계전 그래픽 동작 시뮬레이터)

  • Min, S.U.;Lee, S.J.;Choi, M.S.;Kim, K.J.;Kim, H.P.;Lee, W.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.902-904
    • /
    • 1998
  • When the faults occur in power systems, the protective relay plays a roles of protecting power systems. It is important that the protective relay have high selectiveity and sencitivity performance in power system by correct setting the relays. This paper proposed a testing methods if the reliability of digital relay as simulating the response of relay at faults in the real power system operation environment.

  • PDF

REffects of Surge Protective Devices with Respect to Types of System Grounding and Wiring Methods (전원계통의 접지방식 및 배선방식에 따른 서지보호기의 효과)

  • 이수봉;이복희;길형준
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.2
    • /
    • pp.90-99
    • /
    • 2004
  • High speed info-communications equipment are required with development of highly information-oriented society, the intelligent industrial facilities and social systems such as administrative, financial and traffic systems, are gradually becoming to automation, which are composed of the integrated circuits and micro-semiconductors, remote control and operation. Thus modern micro-electronic circuits can frequently be damaged by lightning surge. The protection of electronic circuits from lightning overvoltages is concentrated very interesting. In this paper, for the purpose of providing the effective protection method of electronic devices such micro-computers from lightning surges in a residential building, the protection effect of surge protective devices according to types of system groundings were experimentally analyzed. Also the effective installation method of surge protective devices was examined and proposed. The installation of SPDs in retrofits was a high remnant voltage across the protected device owing to the inductance in the long wires to the SPDs. Finally the method of installing the SPD by twisted pain wires is remarkably effective for fast rising transient overvoltages.

A Study on the Digital Protective Relay for Generator Fault Protection (발전기 고장보호를 위한 디지털 계전기에 관한 연구)

  • Jang, Nak-Won;Park, Jeong-Do;Lee, Sung-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.8
    • /
    • pp.1232-1238
    • /
    • 2009
  • As power facilities are getting higher at capacity, the monitoring and diagnosis of generators for fault detection and protection has attracted intensive interest. In case of an after-fault in high capacity rotating machines, the recovering cost is usually very expensive and additional time is necessary for returning in a normal situation. In this paper, we developed the protection program for the generator fault protection system and each module of the digital protective relay H/W for loading the protection program. The protective relay H/W was designed to have EMC characteristics for prohibiting from fault operation in bad power systems.

Degradation of Coatings under Atmospheric Tropical Conditions

  • To, Thi Xuan Hang;Pham, Gia Vu;Vu, Ke Oanh;Trinh, Anh Truc;Kodama, Toshiaki;Tanabe, Hiroyuki;Taki, Tohru;Nagai, Masanori
    • Corrosion Science and Technology
    • /
    • v.2 no.5
    • /
    • pp.207-211
    • /
    • 2003
  • The weather resistance of five coatings systems based on alkyd, chlorinated rubber, epoxy, polyurethane and fluoropolymer were studied by natural exposure test and accelerated test. The coatings were exposed at Hanoi station with urban industry atmosphere and at Baichay station with marine atmosphere. The degradation of coatings was evaluated by gloss measurement and surface analysis by scanning electronic microscopy. The results obtained show that among coatings tested the gloss of polyurethane and fluoropolymer coatings remained highly and those of alkyd, chlorinated rubber and epoxy coatings were very low after two years of atmospheric exposure. Under accelerating conditions the gloss of fluoropolymer coatings remained highly after 80 cycles of testing. By comparison with accelerating test in UV-condensation chamber the conditions at atmospheric stations are more aggressive.