• 제목/요약/키워드: protection tunnel

검색결과 109건 처리시간 0.027초

건축구조물에 적용하기위한 신개발 시멘트계 내화재료의 내화성능에 관한 연구 (Study of fire protection performance of newly developed cementitious fire protection material for application to architectural building)

  • 김장호;박해균;이명섭;원종필;임윤묵;이경민
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.633-636
    • /
    • 2006
  • High-rise and large size buildings require high strength concrete and steel structure as a necessity. However, high strength concrete and steel structure are strong material but have a weakness to high temperature. Therefore, fire protection is a matter that must be considered very importantly in design for structure of high strength concrete and steel. Fire proof board that is existing method for fire proof has relatively low performance in fire protection emphasizes the need of new fire protection material due to the using of in numerable inflammables like plastics. The objective of this study is to understand the fire-resisting performance of newly developed fire protection material for building. This paper describes the results of fire tests using ISO curve that is fire protection regulation for buildings of the newly developed cementitious fire protection coating material applied concrete tunnel lining specimens.

  • PDF

세미워터제트형 연안어선 개발에 관한 연구 (A Study on the Development for the Coastal Fishing Boat attached Protected-Tunnel for Propeller)

  • 고재용;심상목;박충환;서성부;배동균
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2003년도 춘계공동학술대회논문집
    • /
    • pp.16-20
    • /
    • 2003
  • 최근 어선어업 주변환경의 급속한 변화는 기존 어선어업의 구조조정과 새로운 사회, 경제적 환경에 부응하는 선형개발의 요구로 이어지고 있다. 한편, 서ㆍ남해 연안에서 작업 및 항해하는 연안어선들은 노출된 프로펠러에 어망, 로프 등이 감기는 사고가 매년 증가하고 있는 실정이다. 본 연구는 이상과 같은 관점에서 연안어선의 해난사고 방지를 위해 기존 선미형상을 수정한 프로펠러 보호터널 부착 연안어선을 대상으로 모형시험을 통하여 세미워터제트형 연안어선의 주요성능을 분석, 검토한 것이다.

  • PDF

2-Arch 터널의 막장면 종방향 적정 이격거리에 관한 연구 (A study on the longitudinal optimum separated distance of tunnel face in 2-arch tunnel)

  • 이민규;정지수;이성기;이승호
    • 한국터널지하공간학회 논문집
    • /
    • 제9권4호
    • /
    • pp.323-330
    • /
    • 2007
  • 최근 선형분리 곤란, 환경훼손 최소화 및 용지보상 등의 이유로 2-Arch 터널의 채택이 점점 증가하고 있다. 이런 실정에도 불구하고 2-Arch 터널은 국내에서의 시공실적 및 설계사례의 부족으로 자료의 데이터화가 체계적이지 않고 2-Arch 터널의 역학적인 거동 메커니즘에 대한 연구가 미흡한 실정이다. 따라서 본 연구에서는 2-Arch 터널의 종방향 이격거리에 대한 연구를 통해 본선 선행터널과 중앙벽체의 거동 메커니즘을 분석하고 적정 이격거리를 제안하고자 한다. 2-Arch 터널의 이격거리 산정은 터널의 안정이 확보되는 조건에서 산정하는 것이 타당하며, 이격거리에 따라 보다 민감하게 작용하는 중앙 벽체의 거동에 영향을 최소화 할 수 있는 범위내에서 이격거리를 산정하는 것이 바람직할 것으로 판단된다. 또한 이격거리에 따른 중앙벽체의 민감도 분석결과 최대 변곡점이 생겨 급격한 응력변화가 발생하는 0.5D이내를 이격거리로 산정하는 것이 타당할 것으로 사료된다.

  • PDF

각형 출입구를 갖는 방호터널의 방폭밸브에 미치는 폭압 평가 (Blast Overpressure Evaluation for Blast Valves in Protective Tunnels with Rectangular-Shaped Tunnel Entrances)

  • 방승기;신진원
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권4호
    • /
    • pp.79-90
    • /
    • 2021
  • This paper presents a study to reduce the effect of blast pressure on the blast valves installed in protection tunnels, where the shape of the tunnel entrance and the blast pocket is optimized based on the predetermined basic shape of the protective tunnels. The reliability of the numerical tunnel models was examined by performing analyses of mesh convergence and overpressure stability and with comparison to the data in blast-load design charts in UFC 3-340-02 (DoD, 2008). An optimal mesh size and a stabilized distance of overpressure were proposed, and the numerical results were validated based on the UFC data. A parametric study to reduce the blast overpressures in tunnel was conducted using the validated numerical model. Analysis was performed applying 1) the entrance slope of 90, 75, 60, and 45 degrees, 2) two blast pockets with the depth 0.5, 1.0, and 1.5 times the tunnel width, 3) the three types of curved back walls of the blast pockets, and 4) two types of the upper and lower surfaces of the blast pockets to the reference tunnel model. An optimal solution by combining the analysis results of the tunnel entrance shape, the depth of the blast pockets, and the upper and lower parts of the blast pockets was provided in comparison to the reference tunnel model. The blast overpressures using the proposed tunnel shape have been reduced effectively.

A RESEARCH ON EFFECTIVE FIRE/DISASTER PROTECTION OF UTILITY TUNNEL IN KOREA

  • Park, Hung-joo;Son, Bong-sei;Jee, Nam-yong
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.404-412
    • /
    • 1997
  • The pipes and cables buried below ground, which may have helped to improve city landscape, is becoming direct and indirect causes for various kinds of disaster in Korea. Every advantage from the use of utility tunnel can not be converted in a dollar since there is associated huge contribution to safe urban environment. The Korean government has a certain role to play in helping promote utility tunnels for the past years. Most recently, many utility tunnels have been being checked to find out safety level, especially fire safety level, and main problems and shortcomings are checked out as a result of this survey. Because the fire safety level of existing tunnel is low, possible approaches and solutions are presented according to the analysis of fire safety level. In order for these approaches to be effective, existing tunnel should be supplemented appropriately and extra equipment must be installed according to the solutions. Hopefully, by performing both improvement of existing utility tunnel that provide a fire/disaster proof and introducing new types of tunnel which influence utility management and maintenance, the recent disaster rate in Korea can be diminished up to a desirable rate in a near future.

  • PDF

Study of microstructure of carbon-based materials in plasma wind tunnel testing

  • Kang, Bo-Ram;Lim, Hyeon-Mi;Oh, Phil-Yong;Hong, Bong Guen
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.200.2-200.2
    • /
    • 2016
  • Carbon-based materials have been known as ablative material and have been used for thermal protection systems. Ablation is an erosive phenomenon that results in thermochemical and thermomechanical changes on materials. Ablation resistance is one of the key properties that determines performance and life-time of the thermal protection material under ablative conditions. In this study, ablation properties of graphite, 3-dimensional (C/C) composites (needle-punched type and rod type) were investigated byusing a plasma wind tunnel which produce a supersonic plasma flow from a segmented arc heater with the power level of 0.4 MW. The mass losses and surface roughness changes which contain main result of the ablation are measured. A morphological analysis ofthe carbon-based materials, before and after the ablation test, are performed through field emission scanning electron microscopy (FE-SEM) and non-contact 3D surface measuring system. Electronic balance and a portable surface roughness tester were used for evaluation of the recession and mass loss of the test samples.

  • PDF

바우 스러스터 터널 그리드 개선을 위한 연구 (A Development of New Device for Bow Thruster Tunnel Grids)

  • 김성표;박제준;전동수;김용수;이춘주
    • 대한조선학회논문집
    • /
    • 제43권3호
    • /
    • pp.304-312
    • /
    • 2006
  • For protection of the thruster against mechanical damage and reduction of tunnel resistance at ship forward speed, the tunnel grids are normally installed. Some of ship operators however, have a strong distrust of the protective function of the tunnel grids and so they do not want to install the protective grids for higher thruster efficiency. Since the grids should be installed at very close to the side shell as far as possible in due consideration of flow direction to minimize additional resistance induced by tunnel openings, it has been too hard and time consuming work to install the grids on the curved and chamfered tunnel entrances considering its relatively low resistance reduction effect. DSME (Daewoo Shipbuilding & Marine Engineering Co., Ltd) developed a substituting device named TG (Tunnel Guides) for bow thruster tunnel grids which is characterized by higher resistance reduction, higher thruster efficiency and easy to installation. This paper provides the principle idea of the TG with short history of the development using CFD calculations and model experiments in MOERI (former KRISO).

고속철도 터널의 정량적 위험도 분석(QRA)을 위한 세부기준에 관한 고찰 (Review on the detailed standards for Quantitative Risk Analysis in High Speed Railway Tunnels)

  • 최원일;최정환;문연오;김선홍;유호식
    • 터널과지하공간
    • /
    • 제18권6호
    • /
    • pp.393-407
    • /
    • 2008
  • 철도터널에서의 화재 등과 같은 불의의 사고를 예방하고 사고 발생시에는 피해를 최소화하기 위하여 철도시설에 대한 안전기준이 필요하게 되었으며, 건설교통부(현 국토해양부)에서는 "철도시설 안전기준에 관한 규칙(2005년 10월 27일)"과 "철도시설 안전세부기준(2006년 9월 22일)"을 고시하여 일반철도와 고속철도 터널에 적용하도록 하였다. 이러한 방재관련 법규는 터널 방재설비의 과다 및 과소 설계를 방지하기 위하여 5가지 주요시설물(방연문, 배연설비, 대피통로 접속부, 대피통로 간격, 연결송수관 설비)에 대하여 안전성 분석결과에 따라 설치하도록 하여 많은 비용과 시간이 소요되는 방패시설물의 합리적인 설치방안을 제시하였다. 그러나, 안전성 분석방법은 기존 사고사례 및 자료를 토대로 화재강도, 가능한 시나리오, 사건발생 가능성, 사고영향, 사고발생확률 등에 대한 세부적인 분석방법에 따라 안전성 분석 결과의 차이가 크므로 이에 대한 구체적인 기준이 필요하다. 따라서, 본 논문에서는 고속철도 터널 안전성 분석에 대하여 단계별로 세부적인 수행방법을 소개하였으며, 이를 참고하여 합리적인 범위 및 기준을 개발하는 데 어느 정도 기여할 수 있을 것으로 판단된다.

Design criteria of wind barriers for traffic -Part 1: wind barrier performance

  • Kwon, Soon-Duck;Kim, Dong Hyawn;Lee, Seung Ho;Song, Ho Sung
    • Wind and Structures
    • /
    • 제14권1호
    • /
    • pp.55-70
    • /
    • 2011
  • This study investigates the design criteria required for wind barriers to protect vehicles running on an expressway under a high side wind. At the first stage of this study, the lateral deviations of vehicles in crosswinds were computed from the commercial software, CarSim and TruckSim, and the critical wind speeds for a car accident were then evaluated from a predefined car accident index. The critical wind speeds for driving stability were found to be 35 m/s for a small passenger car, yet 30 m/s for a truck and a bus. From the wind tunnel tests, the minimum height of a wind barrier required to reduce the wind speed by 50% was found to be 12.5% of the road width. In the case of parallel bridges, the placement of two edge wind barriers plus one wind barrier at center was recommended for a separation distance larger than 20 m (four lanes) and 10 m (six lanes) respectively, otherwise two wind barriers were recommended.