• Title/Summary/Keyword: protection circuit module

Search Result 51, Processing Time 0.028 seconds

Development of hybrid system with fuel cell and lithium secondary battery (연료전지와 리튬 이차전지의 하이브리드 시스템 개발)

  • Hwang, Sangmoon;Jung, Eunmi;Son, Dongun;Shim, Taehee;Song, Hayoung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.143.2-143.2
    • /
    • 2010
  • Therefore, with this development assignment we'd like to develop the hybrid system combining 800W DMFC (Direct Methanol Fuel Cell) and 1.6kW of Lithium secondary battery pack which can be applied to the most common small cart. a scooter, to secure the development capability of hundreds of Watts DMFC, the high-capacity Lithium secondary battery pack, the technology of BMS (Battery Management System) and the development technology of hybrid system. DMFC, in fact, has lower energy efficiency than PEMFC (Polymer Electrolyte Membrane Fuel Cell); however, it has several advantages in terms of fuel storage and use. It is pretty easy to be stored and used without any additional colling and heating devices because of its insensitive liquid methanol to temperature. In conclusion, DMFC system is the most suitable device for small mobile vehicles.

  • PDF

Effect of Protection Circuit Module for Li-Secondary Battery on Electrolyte Leakage (전해액 누액에 의한 리튬이차전지 보호회로의 영향)

  • Nam, Jong-ha
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.413-414
    • /
    • 2016
  • 리튬이차전지는 양극과 음극이 충전과 방전을 반복적으로 수행할 수 있는 구조를 가지고 있으며, 전극 내에서의 이온의 삽입 및 탈리가 용이하고 이들 과정이 진행되는 동안 전극의 구조가 안정하게 유지되어야 하는 전해질은 이온의 전달을 용이하게 하여야 한다. 전지에서 전극 내로 삽입되는 이온은 집전체를 통해 전극으로 들어온 전자와 전하중성을 이루어 전극 내에 전기 에너지를 저장하는 매개체가 된다. 리튬이차전지에서 전해액은 유기 전해액이 사용되고 있으며, 유기용매에 이온원으로서 용질인 리튬염을 용해시킨 것이지만 폭 넓은 환경조건하에서도 이온의 이동을 계속적으로 원활하게 하여 실용전지로서 충분한 역할을 하도록 만드는 중요한 재료이다. 본 논문에서는 전지에서 유기 전해액의 누액이 발생시 보호회로에 미치는 영향에 대해 소개하고자 한다.

  • PDF

Design of Power Factor Correction IC for 1.5kW System Power Module (1.5kW급 System Power Module용 Power Factor Correction IC 설계)

  • Kim, Hyoung-Woo;Seo, Kil-Soo;Kim, Ki-Hyun;Park, Hyun-Il;Kim, Nam-Kyun
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.499-500
    • /
    • 2008
  • In this paper, we design and implement the monolithic power factor correction IC for system power modules using a high voltage(50V) CMOS process. The power factor correction IC is designed for power applications, such as refrigerator, air-conditioner, etc. It includes low voltage logic, 5V regulator, analog control circuit, high-voltage high current output drivers, and several protection circuits. And also, the designed IC has standby detection function which detects the output power of the converter stage and generates system down signal when load device is under the standby condition. The simulation and experimental results show that the designed IC acts properly as power factor correction IC with efficient protective functions.

  • PDF

Study on the High and High Voltage 35 kW, 50 kV Inverter Power Supply (대출력 고전압 35 kW, 50 kV 인버터 전원장치 개발에 관한 연구)

  • Son, Yoon-Gyu;Jang, Sung-Duck;Oh, Jong-Seok;Cho, Moo-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.11
    • /
    • pp.628-634
    • /
    • 2002
  • A capacitor-charging power supply using high frequency inverter technology is strongly recommended for the charging section of the pulsed power supplies. A high frequency inverter swiching makes the overall system size small. The command-charging feature can guarantee the higher reliability of switching function. The protection circuit can be easily included in the system and the good regulation of charging voltage can be acieved by the feedback system. Several modules can be stacked to supply required output power and a failed module can be easily replaced. A 50-kV, 35-kW capacitor charging power supply is developed. In this paper the detailed design and test results of a prototype unit are presented.

A solid-state switch based high-voltage pulsed power supply (반도체 스위치형의 고전압 펄스 전원장치)

  • Kim, Guang-Hoon;Lee, Hong-Sik;Sytykh, D.;Rim, Geun-Hie
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.215-217
    • /
    • 2001
  • This paper describes an all solid-state switch pulse generator for various applications where square pulse voltage is required. The pulse generator produces various voltage pulses: voltage $5{\sim}100kV$. current $10{\sim}200A$, pulse width $1{\sim}10{\mu}sec$, repetition rate up to 500Hz. The output power is the combination of these parameters up to 10kW. It consists of a DC-DC converter and several pulse generating modules which are connected in series to obtain higher pulse voltage. Each module contains semiconductor switches (IGBT's), energy storage capacitors and control units to trigger switches. The structure and operational principle are described and the protection circuit for reliable operation is suggested. Experimental results show that the pulse generator can be used for applications with nonlinear loads.

  • PDF

A Design and Implementation of Matrix Converter Based on Space Vector Modulation (SVM를 적용한 매트릭스 컨버터의 설계 및 구현)

  • Yang, Chun-Suk;Yoon, In-Sik;Kim, Kyung-Seo
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.23-26
    • /
    • 2005
  • This paper describes the design, construction and implementation of matrix converter based on space vector modulation technique. The matrix converter provides sinusoidal input and output wave forms, bidirectional power flow, controllable input power factor and a compact design, compared to the VSI with diode rectification stage at the input. The implemented prototype of matrix converter is built using the exclusive IGBT module and has an input filter, overvoltage protection circuit and commutation means for overcoming practical issues. The good results tested using an induction motor are also presented.

  • PDF

Analysis of Fire Risk through Battery Fire Cases and Experiments of Wearable Devices (웨어러블 기기의 배터리화재사례와 실험을 통한 화재위험성 분석)

  • Lee, Jung-Il
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.2
    • /
    • pp.47-55
    • /
    • 2020
  • This study analyzed ignition probability about Lithium-polymer batteries of what variously were being produced wearable devices recently. The study analyzed ignition probability by PCM(Protection Circuit Module) operating state and overcharged, over-discharged, exposed to high temperatures of Lithium polymer batteries, analyzing wearable devices on the market. Then it classified experimental results to implement analysis comparison about weight, X-ray imaging, battery decomposition. With these experiments, the study analyzed combustion-possibility and fire patterns. These statistics will be used to measure and verify the cause of a fire when identify wearable devices using Lithium-polymer batteries.

Electrical Characteristic of Power MOSFET with Zener Diode for Battery Protection IC

  • Kim, Ju-Yeon;Park, Seung-Uk;Kim, Nam-Soo;Park, Jung-Woong;Lee, Kie-Yong;Lee, Hyung-Gyoo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.1
    • /
    • pp.47-51
    • /
    • 2013
  • A high power MOSFET switch based on a 0.35 ${\mu}m$ CMOS process has been developed for the protection IC of a rechargeable battery. In this process, a vertical double diffused MOS (VDMOS) using 3 ${\mu}m$-thick epi-taxy layer is integrated with a Zener diode. The p-n+Zener diode is fabricated on top of the VDMOS and used to protect the VDMOS from high voltage switching and electrostatic discharge voltage. A fully integrated digital circuit with power devices has also been developed for a rechargeable battery. The experiment indicates that both breakdown voltage and leakage current depend on the doping concentration of the Zener diode. The dependency of the breakdown voltage on doping concentration is in a trade-off relationship with that of the leakage current. The breakdown voltage is obtained to exceed 14 V and the leakage current is controlled under 0.5 ${\mu}A$. The proposed integrated module with the application of the power MOSFET indicates the high performance of the protection IC, where the overcharge delay time and detection voltage are controlled within 1.1 s and 4.2 V, respectively.

Development of a High Voltage Semiconductor Switch for the Command Charging o (모듈레이터의 지령충전을 위한 고전압 반도체 스위치 개발)

  • Park, S.S.;Lee, K.T.;Kim, S.H.;Cho, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2067-2069
    • /
    • 1998
  • A prototype semiconductor switch for the command resonant charging system has been developed for a line type modulator, which charges parallel pulse forming network(PFN) up to voltage of 5 kV at repetition rates of 60 Hz. A phase controlled power supply provides charging of the 4.7 ${\mu}s$ filter capacitor bank to voltage up to 5 kV. A solid state module of series stack array of sixe matched SCRs(1.6 kV, 50 A) is used as a command charging switch to initiate the resonant charging cycle. Both resistive and RC snubber network are used across each stage of the switch assembly in order to ensure proper voltage division during both steady state and transient condition. A master trigger signal is generated to trigger circuits which are transmitted through pulse transformer to each of the 6 series switch stages. A pulse transformer is required for high voltage trigger or power isolation. This paper will discuss trigger method, protection scheme, circuit simulation, and test result.

  • PDF

Intelligent Motor Control System Based on CIP (CIP 기반의 지능형 전동기 제어 시스템)

  • Kim, On;Choi, Seong-Jin
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.2
    • /
    • pp.307-312
    • /
    • 2020
  • This paper proposed intelligent motor control system that replaced smart motor devices, such as motor protection relays, smart circuit breakers and variable speed drives, with one integrated module to perform efficient motor control at industrial sites. The proposed intelligent motor control system provides easy monitoring of critical data for each motor or load connected to an intelligent motor control system over a CIP(Common Industrial Protocol)-based network, which enables accurate process control at all times, real-time access to fault information and records to simplify diagnosis and minimize equipment downtime.