Radiation prosthetic stents applied to oral cancer patients during the radiation therapy: case reports (효율적 방사선요법을 위한 구강 방사선스텐트의 적용: 증례보고)

  • Nam, Ki Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.282-288
    • /
    • 2020
  • Radiation prosthetic stent is defined as the customized oral devices which serve for an efficient administration of radiation dose to the affected areas or a minimizing the unnecessary irradiation to surrounding normal tissues during maxillofacial cancer radiotherapy. Since the use of stents is individualized, a close collaboration among radiotherapist, surgeon and prosthodontist is essential thereby which helps in limiting the post-therapy morbidity as well as the stable oral rehabilitation. In this report, two customized stents (bolus carrier and tongue depressing) were fabricated and applied to patient undergone irradiation for soft palate and tongue carcinoma selectively. Multidisciplinary approach can be a proper strategy and recommended for control the sequel of post-irradiation.

Full Mouth Rehabilitation in a Patient with Limited Restorable Space (수복 공간이 부족한 환자에서의 완전구강회복)

  • Lim, Kwang-Gil;Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.145-156
    • /
    • 2010
  • Loss of posterior support may cause overloading and excessive wear of remaining teeth. Moreover, the extrusion of antagonistic teeth leads to the destruction of the occlusal plane. The loss of vertical dimension of occlusion (VDO) also emerges clinically, which may bring the loss of esthetic appearance and function. These patients who suffer from the loss of posterior support, often require vigorous periodontal treatments (osteotomy, crown lengthening) and extensive oral rehabilitation. Sixty three years old female patient visited for the prosthetic treatment of the posterior edentulous area. She had no other systematic disease and parafuctional habits for prosthetic treatment. Intraoral and radiographic examinations were done. The evaluation of VDO and vertical dimension of rest position were evaluated for proper prosthetic procedures and diagnostic wax up was done. As a result of diagnosis, VDO was increased by 2 mm considering the loss of VDO and space for the prosthetic treatment. After the pretreatments, initial preparation of teeth and provisionalization were carried out. Six weeks later of provisionalizaion, final preparation and impression was performed. Using the duralay resin copings, jaw relation was registered. The master cast was mounted and definitive restoration was fabricated. After the evaluation of esthetic and function, pick up impression for clinical remounting was done. Lucia jig was made for new jaw relation and occlusal adjustment on the articulator. Definitive restoration was delivered and the patient was periodically recalled for additional occlusal adjustment. From this case, the satisfactory functional and esthetic results through full mouth rehabilitation with increase vertical dimension were achieved.

sEMG Signal based Gait Phase Recognition Method for Selecting Features and Channels Adaptively (적응적으로 특징과 채널을 선택하는 sEMG 신호기반 보행단계 인식기법)

  • Ryu, J.H.;Kim, D.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.19-26
    • /
    • 2013
  • This paper propose a surface EMG signal based gait phase recognition method that selects features and channels adaptively. The proposed method can be used to control powered artificial prosthetic for lower limb amputees and can reduce overhead in real-time pattern recognition by selecting adaptive channels and features in an embedded device. The method can enhance the classification accuracy by adaptively selecting channels and features based on sensitivity and specificity of each subject because EMG signal patterns may vary according to subject's locomotion convention. In the experiments, we found that the muscles with highest recognition rate are different between human subjects. The results also show that the average accuracy of the proposed method is about 91% whereas those of existing methods using all channels and/or features is about 50%. Therefore we assure that sEMG signal based gait phase recognition using small number of adaptive muscles and corresponding features can be applied to control powered artificial prosthetic for lower limb amputees.

  • PDF

Prosthetic rehabilitation for a glossectomy patient - a clinical report (혀절제술을 시행한 환자의 보철적 수복 증례)

  • Yoon, Jiyoung;Lee, Siho;Lee, Jiyoen;Oh, Namsik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.347-352
    • /
    • 2013
  • Malignant tumours of the oral cavity that require resection of the tongue result in severe deficiencies in speech and deglutition. In such patients, improvements in mastication, swallowing, and speech may be reasonable goals for treatment. The viability of a prosthodontic approach to treatment depends on the type and extent of surgery. In a total glossectomy, a mandibular tongue prosthesis is the treatment of choice. Mandibular tongue prosthesis occupies the space in the floor of the oral cavity. It provides the patients with a platform for directing food into the esophagus and aids in speaking. This type of prosthesis can achieve that protection of the underlying fragile tissue and improvement in appearance and psychosocial adjustment. This case report describes the technical steps involved in prosthetic rehabilitation for a glossectomy patient.

Can prosthetic limbs made too quickly cause kidney damage?: a pilot study

  • Petrofsky, Jerrold S.;Browne, Mary;Jamshidi, Mahyar;Libo-on, Anthony;Lee, Haneul
    • Physical Therapy Rehabilitation Science
    • /
    • v.3 no.2
    • /
    • pp.119-124
    • /
    • 2014
  • Objective: The use of chemicals for building prosthetic sockets present the possibility of being hazardous and unsafe due to off-gassing. The purpose of the present study was to investigate if freshly made materials used in prosthetic sockets causes off-gassing that would penetrate the skin and cause damage to the kidneys or blood. Design: Cross-sectional study. Methods: In this research, the off-gassing effects during the initial curing process of styrene monomer, vinyl ester resin, epoxy methacrylate resin, benzene-1, 3-dimethaneamine, trimethylhexanedlamine, and paratertiarybutylphenol were analyzed. Acid detection strips were placed inside newly fabricated mock-prosthetic sockets and left overnight in a closed environment to find out if acid was present in the invisible fumes. The plastic was worn by 9 subjects and urinalysis was made after 48 hours to test for any kidney or blood toxicity of the resins. Results: After wearing the plastic cuff for 48 hours, the ratio of protein to creatinine in the urine was raised to an abnormal level in five out of nine subjects. Four out of the nine subjects showed normal protein to creatinine ratios after wearing the device. The results showed that damage to the kidney occurred from wearing the resins after curing in half of the subjects. Conclusions: It is very important to conduct patient intakes which includes the assessment of renal function. Off-gassing in vented chambers may be needed to protect both prosthetists and patients.

Prosthetic management of a growing patient with Russell-Silver syndrome: a clinical report

  • Kim, Kanghyun;Noh, Kwantae;Paek, Janghyun;Kwon, Kung-Rock;Pae, Ahran
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.5
    • /
    • pp.406-410
    • /
    • 2015
  • Russell-Silver syndrome (RSS) is a congenital disease characterized by short stature due to growth hormone deficiency, physical asymmetry, inverted triangular face, micrognathia, prominent forehead, and hypodontia. This case report presents a prosthetic management of a 6-year-old patient with Russell-Silver syndrome treated with overdentures on the maxilla and the mandible using the remaining primary teeth. Subsequent and comprehensive dental management considering the growth and development of a young patient will be necessary.

Effects of Prosthetic Mass Distribution on Musculoskeletal System during Amputee Gait (의지 보행시 의지 무게 분포가 근골격계에 미치는 영향)

  • Bae, Tae-Soo;Choi, Hwan;Kim, Shin-Ki;Mun, Mu-Seong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.8 s.197
    • /
    • pp.130-137
    • /
    • 2007
  • The optimized prosthetic mass distribution was a controversial problem in the previous studies because they are not supported by empirical evidence. The purpose of the present study was to evaluate the effect of prosthetic mass properties by modeling musculoskeletal system, based on the gait analysis data from two above-knee amputees. The joint torque at hip joint was calculated using inverse dynamic analysis as the mass was changed in knee and foot prosthetic components with the same joint kinematics. The results showed that the peak flexion and abduction torque at the hip joint were 5 Nm and 15 Nm when the mass of the knee component was increased, greater than the peak flexion and abduction torque of the control group at the hip joint, respectively. On the other hand, when the mass of the foot component was increased, the peak flexion and abduction torque at the hip joint were 20 Nm and 15 Nm, greater than the peak flexion and abduction torque of the control, respectively. The hip flexion torque was 4.71-fold greater and 7.92-fold greater than the hip abduction torque for the knee mass increase and the foot mass increase on the average, respectively. Therefore, we could conclude that the effect of foot mass increase was more sensitive than that of knee mass increase for the hip flexion torque. On the contrary, the mass properties of the knee and foot components were not sensitive for the hip abduction torque. In addition, optimized prosthetic mass and appropriate mass distributions were needed to promote efficiency of rehabilitation therapy with consideration of musculoskeletal systems of amputees.

Comparisons of Kinematic Factors and Stiffnesses of the Lower-limb Joints between Transfemoral Amputees and Normal Adults (대퇴절단자와 정상인 걸음걸이의 운동학적 요인과 발목관절 강성 비교)

  • Yi, Jae-Hoon;Lee, Jung-Ho;Hah, Chong-Ku
    • Korean Journal of Applied Biomechanics
    • /
    • v.23 no.1
    • /
    • pp.77-83
    • /
    • 2013
  • The purpose of this study was to compare kinematic variables and stiffnesses of ankle joints between normal person and transfemoral amputee gait in order to develop or fit prosthetic leg. Twenty subjects (ten normal persons and ten transfemoral amputees) participated in this experiment, and walked three trials at a self-selected pace. The gait motions were captured with Vicon system and variables were calculated with Visual-3D. The velocity, stride length, stride width, cycle time, double limb support time and right swing time of gaits were statistically significant. Because coefficients of variability of normal persons on velocity, double limb support time and swing time were greater than transfemoral amputees, normal persons controlled these gait variables effectively. The stiffnesses of ankle joints were not statistically significant, but patterns of stiffnesses of ankle joints during three rockers were absolutely different. The negative correlations between stiffnesses of ankle joints and cycle time and swing time were presented. These differences suggest that developing and fitting prosthetic leg were demanded. Further studies should develop fitting program and simulator of prosthetic leg.

Prosthodontic rehabilitation of a patient with bilateral auricular deformity

  • Mantri, Sneha Shivkumar;Thombre, Ram U.;Pallavi, Daigavane
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.2
    • /
    • pp.101-105
    • /
    • 2011
  • Maxillofacial prosthodontics is an art and science which provides life like appearance to the person with facial deformity. Maxillofacial prosthetic rehabilitation for acquired defects has become more complex and sophisticated with advancement in techniques and materials. This case report describes the clinical and laboratory procedure for fabricating an auricular prosthesis for a patient with trauma related bilateral auricular deformity. Ear prosthesis was fabricated in two parts taking retention from external auditory canal.

Design of Compact Magneto-Rheological Fluid Damper for Artificial Low-Limb Prosthesis (Magneto-Rheological Fluid를 이용한 인공지능 의족의 Compact damper 개발)

  • Sung, So-Young;Kang, S.J.;Moon, I.H.;Moon, M.S.;Jang, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2962-2964
    • /
    • 2005
  • Magneto-Rheological (MR) fluid is suspension of fine magnetic particles in a liquid carrier such as silicon oil or water. MR fluid exhibits solid-like mechanical behavior into chain or clusters with high yield stress when magnetic field is applied to the particles. The response of MR fluids is very quick and reversible after removal of the field. MR Fluids have high yield stress (up to 5kPs) and operate in low voltage power supply. Recently, MR damper using MR fluids was open used in vibration control system such as structural devices, seat vibration controllers and helicopter rotor systems, but it is too big in size and heavy. Therefore, it is not appreciate to rehabilitation devices such as prosthetic limbs.

  • PDF