• Title/Summary/Keyword: prosthesis and implants

Search Result 389, Processing Time 0.028 seconds

APPLICATION OF FINITE ELEMENT ANALYSIS TO EVALUATE PLATFORM SWITCHING

  • Kim Yang-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.6
    • /
    • pp.727-735
    • /
    • 2005
  • Statement of problem. Platform switching in implant prosthesis has been used for esthetic and biological purpose. But there are few reports for this concept. Purpose. The purpose of this study is evaluation of platform switching in wide implant by three dimensional finite element analysis. Materials and Methods. The single implant and prosthesis was modeled in accordance with the geometric designs for Osstem implant system. Three-dimensional finite element models were developed for (1) a wide diameter 3i type titanium implant 5 mm in diameter, 13 mm in length with wide cemented abutment, titanium alloy abutment screw, and prosthesis (2) a wide diameter 3i type titanium implant 5 mm in diameter, 13 mm in length with regular cemented abutment, titanium alloy abutment screw and prosthesis(platform switching) was made for finite element analysis. The abutment screws were subjected to a tightening torque of 30 Ncm. The amount of preload was hypothesized to 650N, and round and flat type prostheses were loaded to 200 N. Four loading offset point (0, 2, 4, 6 mm from the center of the implants) were evaluated. Models were processed by the software programs HyperMesh and ANSA. The PAM-CRASH 2G simulation software was used for analysis of stress. The PAM-VIEW and HyperView were used for post processing. Results. The results from experiment were as follows; 1. von Mises stress value is increased in order of bone, abutment, implant and abutment screw. 2. von Mises stress of abutment screw is lower when platform switching. 3. von Mises stress of implant is lower when platform switching until loading offset 4 mm. 4. von Mises stress of abutment is similar between each other. 5. von Mises stress of bone is slightly higher when platform switching. Conclusion. The von Mises stress pattern of implant components is favor when platform switch ing but slightly higher in bone stress distribution than use of wide abutment. The research about stress distribution is essential for investigation of the cortical bone loss.

Clinical Evaluation of Occlusal Contact Changes in Implant Prosthesis (임플란트 보철의 교합 접촉 변화에 대한 임상적 평가)

  • Yun, Chul-Hee;Kim, Dae-Gon;Yi, Yang-Jin;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.1
    • /
    • pp.21-30
    • /
    • 2007
  • Despite of the successful clinical performance of implants, it is still lacking of the knowledge of changes in implant occlusion. The purpose of this study was to evaluate the changes of infraocclusal contact after clinical occlusal function of implant. Twenty patients(38 implants) were recalled during 10 months after placement of implant prosthesis. Occlusion changes were investigated at placement, placement 1 months, 4 months and 10 months serially with silicone bite material and T-Scan II sensor. Bony changes were also evaluated with periapical radiographs. The changes of silicone thickness and T-Scan II sensored areas were statistically analyzed with repeated measured ANOVA and the Scheffe's post-hoc test at the 95% significance level. The following results have been made based on this study: 1. Alveolar bone loss was within 0.20mm and it was generally concluded within physiologic level. 2. There were no statistically significant differences in the thickness changes of silicone material at 1 month and 4 months of occlusal function. However, there was statistically significant difference at 10 months of occlusal function (p<0.05). 3. There was no statistically significant difference in changes of occlusal contact area in T-Scan II at 1 month and 4 months of occlusal function, but there was statistically significant difference at 10 months of occlusal function (p<0.05). Conclusively, as time goes by, implant occlusion to be formed infraocclusion was to be far close and increased occlusal contact. However, it was not observed destructive bone resorption in periapical radiographs and any other side effects.

Numerical modeless of the damage, around inclusion in the orthopedic cement PMMA

  • Mohamed, Cherfi;Smail, Benbarek;Bouiadjra, Bachir;Serier, B.
    • Structural Engineering and Mechanics
    • /
    • v.57 no.4
    • /
    • pp.717-731
    • /
    • 2016
  • In orthopedic surgery and more especially in total arthroplastie of hip, the fixing of the implants generally takes place essentially by means of constituted surgical polymer cement. The damage of this materiel led to the fatal rupture and thus loosening of the prosthesis in total hip, the effect of over loading as the case of tripping of the patient during walking is one of the parameters that led to the damage of this binder. From this phenomenon we supposed that a remain of bone is included in the cement implantation. The object of this work is to study the effect of this bony inclusion in the zones where the outside conditions (loads and geometric shapes) can provoke the fracture of the cement and therefore the aseptic lousing of the prosthesis. In this study it was assumed the presence of two bones -type inclusions in this material, one after we analyzed the effect of interaction between these two inclusions damage of damage to this material. One have modeled the damage in the cement around this bone inclusion and estimate the crack length from the damaged cement zone in the acetabulum using the finite element method, for every position of the implant under the extreme effort undergone by the prosthesis. We noted that the most intense stress position is around the sharp corner of the bone fragment and the higher level of damage leads directly the fracture of the total prosthesis of the hip.

Multidisciplinary approach of the problem of unaesthetic implants in the maxillary anterior dentition (비심미적 임플란트의 심미성 회복을 위한 다각적 접근법)

  • Joo, Ji-Young;Choi, Jeomil;Lee, Ju-Youn
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.2
    • /
    • pp.126-133
    • /
    • 2015
  • Periodontal tissue destroyed by inflammation is difficult to achieve regeneration of the tissue and esthetic restorations only by surgical methods. In particular, improvement of esthetics is more difficult if the problem is related to the implant. A 23 year old woman suffered from unesthetic anterior implant prosthesis. According to her dental history, a repeated bone graft and soft tissue graft failed at a local dental clinic. It was needed to resolve the inflammation and to improve the esthetics. A free gingival graft and ridge augmentation accompanied by guided bone regeneration and a vascularized interpositional periosteal connective tissue graft was performed. Instead of implant prosthesis, a conventional fixed bridge was adopted for better esthetic result. The patient was satisfied with the esthetic conventional fixed prosthesis. This case report introduces esthetic rehabilitation of unesthetic implant prosthetics in the maxillary anterior dentition by a combination of surgical and prosthetic approaches.

A STUDY ON THE OSSEOINTEGRATED PROSTESIS USING THREE DIMENSIONAL FINITE ELEMENT METHOD (골유착성 보철물에 관한 삼차원 유한요소분석적 연구)

  • Kim, Dong-Won;Kim, Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.1
    • /
    • pp.167-213
    • /
    • 1991
  • The successful replacement of missing teeth has been one driving aim behind the emergence of implant dentistry as both a technology and clinical vocation for over four decades. To date, a multitude of dental implant devices had been designed and utilized in the patient population. Most of these devices have been designed without support of the engineering criteria. The long-term success of any dental implant is dependent upon the optimization of stresses which occurs during oral function and parafunction. Although many studies have examined the biologic interactions between dental implants and living tissue, few studies have been reported on the biomechanical aspects of dental implants. The purpose of this study was to analyze the stress distribution of osseointegrated prosthesis on certain conditions, such as amount of load, location of load, length of fixtures, number of fixtures used, arch shape, bone quality, etc. Three dimentional finite element analysis was used for this study. FEM models were created using commercial software(Super SAP. for IBM 16 bit AT computer. All elements were 8-node brick, isoparametric. Mandible and prosthesis was modeled with 780 elements and 1074 nodes. The results were as follows : 1. In case of cantilever extension, there was a compressive stress at the base of the first implant and a tensile stress at the base of the second implant. 2. The stresses were linearly proportional to the amount of load. 3. The stresses were linearly proportional to the length of cantilever. 4. There was a stress concentration at the neck of the implant and bone under horizontal loads.

  • PDF

Application of digital implant system on implant treatment with "all-on-4" concept (디지털 임플란트 시스템을 전용한 "All-on-4" 개념의 임플란트 보철 증례)

  • Kim, Yong-Jun;Jeong, Seung-Mi;Kim, Kyeong-Hee;Fang, Jeong-Whan;Kim, Dae-Hwan;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.1
    • /
    • pp.88-94
    • /
    • 2018
  • Recently, digital implant systems are expanding its influence in dental area. Due to technical improvement, they jumped over their limits nowadays. We can use these newest systems to treat edentulous patient, from implant surgery to fabrication of prosthesis. In this case, The patient was a fifty years old female. She had a full edentulous ridge on mandible and wanted to reconstruct occlusion with using implants. We planned to use digital implant system with "all-on-4" concept on mandible and produced surgical guide for flapless implant surgery. After the surgery, we tried to fabricate full arch prosthesis just using a digital devices and confirmed satisfying result.

Restoration of anterior teeth with dental implant using multilayer zirconia (다층 지르코니아를 이용한 임플란트 전치부 수복 증례)

  • Lee, Sunghee;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kwon, Kung-Rock;Kim, Hyeong-Seob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.469-477
    • /
    • 2021
  • For successful restoration of maxillary anterior implants, both pink esthetics and white esthetics must be satisfied. For pink esthetic part, the role of appropriate provisional prosthesis restoration is important, and for white esthetic part, the color and shape of the definitive prosthesis is important. Multilayer zirconia can be used for natural tooth appearance due to the higher transparency of the incisal area compared to the conventional monolithic zirconia. Therefore, in this case, white esthetic part was achieved through multilayer zirconia after recovering function and esthetics through appropriate provisional prosthesis in a patient who lost the maxillary anterior teeth.

Eight-year follow-up of two different removable prostheses using six implants in maxillary edentulous patients (상악 완전 무치악 환자에서 6개의 임플란트를 동반한 두가지 가철성 의치 치료의 8년 경과 관찰 증례)

  • Yang, Seung-Won;Kim, Jong-Eun;Kim, Jee-Hwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.300-304
    • /
    • 2017
  • An implant-supported fixed dental prosthesis (ISFDP) or an implant-supported overdenture (IOD) are good options when treating a completely edentulous jaw opposing natural teeth. However, an ISFDP for a full arch requires sufficient bone quality and quantity, which limits its application. Meanwhile, using an ISFDP as an abutment of a removable partial denture has been considered recently. This clinical report discusses the treatments applied to two patients with edentulous maxillas and opposing natural teeth: one was treated with an IOD and the other was treated with an ISFDP and removable partial denture. Follow-up and management were performed for 8 years.

Reconstruction of failed fixed implant prosthesis accompanied by abutment screw loosening and fracture : A case report (나사풀림과 나사파절이 동반된 실패한 임플란트 고정성 보철물의 회복증례)

  • Bae, Eun-Bin;Shin, Young-Gun;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Huh, Jung-Bo
    • The Journal of the Korean dental association
    • /
    • v.55 no.7
    • /
    • pp.457-466
    • /
    • 2017
  • In the case of failed fixed implant prosthesis accompanied by abutment screw fracture, fractured screw fragment must be removed to use the existing implant fixtures. A 61-year-old male patient, who had a failed maxillary fixed implant prosthesis accompanied by three abutment screw fracture, hoped to reconstruct the maxillary implant prosthesis, while maintaining the existing implant fixtures. To use the existing implant fixtures, fractured screw fragments were removed. A maxillary implant overdenture using available existing implants was planned. Bar-attachment with Locator was used for implant splinting, denture stability, and retention. Final impression was taken after treatment of peri-implantitis. Jaw relation registration was taken to evaluate available interarch space for bar-attachment. After fabricating bar-attachment, centric relation was taken. Implant overdenture using bar-attachment with Locator was delivered after wax-denture evaluation. This case report showed that a satisfactory clinical result was achieved by implant overdenture using existing implant fixtures in a maxillary edentulous patient.

  • PDF

Implant-assisted removable partial denture for severely atrophied mandible (심한 하악 치조제 흡수를 가진 환자에서 임플란트를 이용한 가철성 국소의치로 수복한 증례)

  • Choi, Bada;Kim, Yeun Ju;Lee, Jae Hoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.171-175
    • /
    • 2019
  • Mandible with severe alveolar bone atrophy poses a significant challenge in terms of reproducing clinically acceptable anatomy for a removable prosthesis. To overcome this potential complication, altered cast impression technique is often recommended to capture accurate and functional gingiva tissues. It becomes possible to get proper anchors functional impression by placing 2 implants crowns which were impossible in previous implant overdenture impression technique. In this case, an 80-year old female patient with severe mandibular ridge atrophy was treated with an implant-assisted removable partial denture with two implant crowns on the canine area. An altered cast impression was taken with an individual tray on a metal framework of removable partial denture on both posterior edentulous areas. The patient was satisfied with the final prosthesis after failure of 2 previous prostheses. Clinician had a difficult time to manage disabled patient and patient were suffered with ill-fitting denture due to inaccurate impression in conventional overdenture condition. The oral rehabilitation was completed with placing 2 implants as proper anchor.