Browse > Article
http://dx.doi.org/10.4047/jkap.2021.59.4.469

Restoration of anterior teeth with dental implant using multilayer zirconia  

Lee, Sunghee (Department of Prosthodontics, Graduate School, Kyung Hee University)
Lee, Younghoo (Department of Prosthodontics, Kyung Hee University Dental Hospital)
Hong, Seoung-Jin (Department of Prosthodontics, Kyung Hee University Dental Hospital)
Paek, Janghyun (Department of Prosthodontics, School of Dentistry, Kyung Hee University)
Noh, Kwantae (Department of Prosthodontics, School of Dentistry, Kyung Hee University)
Pae, Ahran (Department of Prosthodontics, School of Dentistry, Kyung Hee University)
Kwon, Kung-Rock (Department of Prosthodontics, School of Dentistry, Kyung Hee University)
Kim, Hyeong-Seob (Department of Prosthodontics, School of Dentistry, Kyung Hee University)
Publication Information
The Journal of Korean Academy of Prosthodontics / v.59, no.4, 2021 , pp. 469-477 More about this Journal
Abstract
For successful restoration of maxillary anterior implants, both pink esthetics and white esthetics must be satisfied. For pink esthetic part, the role of appropriate provisional prosthesis restoration is important, and for white esthetic part, the color and shape of the definitive prosthesis is important. Multilayer zirconia can be used for natural tooth appearance due to the higher transparency of the incisal area compared to the conventional monolithic zirconia. Therefore, in this case, white esthetic part was achieved through multilayer zirconia after recovering function and esthetics through appropriate provisional prosthesis in a patient who lost the maxillary anterior teeth.
Keywords
Computer-aided design-Computer-aided manufacturing (CAD-CAM); Esthetics; Implant-supported dental prosthesis; Multilayer zirconia;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Cho HL, Lee JK, Um HS, Chang BS. Esthetic evaluation of maxillary single-tooth implants in the esthetic zone. J Periodontal Implant Sci 2010;40:188-93.   DOI
2 Gonzalez-Martin O, Lee E, Weisgold A, Veltri M, Su H. Contour management of implant restorations for optimal emergence profiles: guidelines for immediate and delayed provisional restorations. Int J Periodontics Restorative Dent 2020;40:61-70.   DOI
3 Joo HS, Park SW, Yun KD, Lim HP. Complete-mouth rehabilitation using a 3D printing technique and the CAD/CAM double scanning method: A clinical report. J Prosthet Dent 2016;116:3-7.   DOI
4 Brunot-Gohin C, Duval JL, Verbeke S, Belanger K, Pezron I, Kugel G, Laurent-Maquin D, Gangloff S, Egles C. Biocompatibility study of lithium disilicate and zirconium oxide ceramics for esthetic dental abutments. J Periodontal Implant Sci 2016;46:362-71.   DOI
5 Kim M, Lee DH. Influence of extraoral polishing of the crown-abutment interface on the marginal fit of screw- and cement-retained prostheses: a clinical pilot study. Int J Prosthodont 2020;33:629-3.
6 Duran JC, Aguirre F, Pino R, Velasquez D. Dimensional variations in the soft tissue profile after removal of implant-supported fixed interim restorations: a pilot clinical study. Implant Dent 2018;27:28-32.   DOI
7 Papadopoulos I, Pozidi G, Goussias H, Kourtis S. Transferring the emergence profile from the provisional to the final restoration. J Esthet Restor Dent 2014;26:154-61.   DOI
8 Belser UC, Grutter L, Vailati F, Bornstein MM, Weber HP, Buser D. Outcome evaluation of early placed maxillary anterior single-tooth implants using objective esthetic criteria: a cross-sectional, retrospective study in 45 patients with a 2- to 4-year follow-up using pink and white esthetic scores. J Periodontol 2009;80:140-51.   DOI
9 Doliveux S, Jamjoom FZ, Nadra M, Gallucci GO, Hamilton A. Fabrication technique for a custom implant emergence profile on 3D printed casts. J Prosthet Dent 2020;123:571-5   DOI
10 Rosentritt M, Preis V, Behr M, Strasser T. Fatigue and wear behaviour of zirconia materials. J Mech Behav Biomed Mater 2020;110:103970.   DOI
11 Li J, Chen Z, Wang M, Wang HL, Yu H. Dynamic changes of peri-implant soft tissue after interim restoration removal during a digital intraoral scan. J Prosthet Dent 2019;122:288-94.   DOI
12 Zhang F, Spies BC, Vleugels J, Reveron H, Wesemann C, Muller WD, van Meerbeek B, Chevalier J. High-translucent yttria-stabilized zirconia ceramics are wear-resistant and antagonist-friendly. Dent Mater 2019;35:1776-90.   DOI
13 Fontolliet A, Al-Haj Husain N, Ozcan M. Wear analysis and topographical properties of monolithic zirconia and CoCr against human enamel after polishing and glazing procedures. J Mech Behav Biomed Mater 2020;105:103712.   DOI
14 Kang CM, Peng TY, Shimoe S. Color accuracy of different types of monolithic multilayer precolored zirconia ceramics. J Prosthet Dent 2020;124:789. e1-7.
15 Galindo-Moreno P, Leon-Cano A, Monje A, Ortega-Oller I, O'Valle F, Catena A. Abutment height influences the effect of platform switching on peri-implant marginal bone loss. Clin Oral Implants Res 2016;27:167-73.
16 Stawarczyk B, Keul C, Eichberger M, Figge D, Edelhoff D, Lumkemann N. Three generations of zirconia: From veneered to monolithic. Part I. Quintessence Int 2017;48:369-80.
17 Erdelt K, Pinheiro Dias Engler ML, Beuer F, Guth JF, Liebermann A, Schweiger J. Computable translucency as a function of thickness in a multi-layered zirconia. J Prosthet Dent 2019;121:683-9.   DOI