• Title/Summary/Keyword: prostheses and Implants

Search Result 223, Processing Time 0.024 seconds

RADIOGRAPHIC EVALUATION OF BONE CHANCE AROUND OSSEOINTEGRATED IMPLANTS IN PARTIALLY EDENTULOUS JAWS WITH FIXED TISSUE-INTEGRATED PROSTHESES (부분무치악 환자에서 기능하중노출이 골유착성 임플란트 주위의 치조골 소실에 미치는 영향에 관한 방사선학적 연구)

  • Yang, Soon-Bong;Han, Dong-Hoo;Yang, Ja-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.1
    • /
    • pp.70-84
    • /
    • 1996
  • This paper reports marginal bone loss around osseointegrated implants after loading in partially edentulous patients in dental hospital, Yonsei University. Two types of implants($Br{\aa}nemark^{TM},\;IMZ^{TM}$) were used. Through the digital measurement on periapical radiograph around 37 implants in human subjects, marginal bone loss was observed for 24 months after delivery of prostheses. The results were as follows; 1. According to experimental periods marginal bone loss in total implants was 1.775 mm at 12 months, 1.921 mm at 24 months after delivery of prostheses(p<0.05). 2. Marginal bone loss in the $Br{\aa}nemark$ implants was 1.831 mm at 12 months, 1.833 mm at 24 months after delivery of prostheses(p<0.05). 3. Marginal bone loss in the IMZ implants was 1.578 mm at 12 months, 2.907 mm at 23 months after delivery of prostheses(p<0.05). 4. During the first year after loading, the IMZ implants showed less marginal bone loss than the $Br{\aa}nemark$ implants but, during the next the $Br{\aa}nemark$ implants showed less than the IMZ implants(p>0.05). These results indicate that marginal bone loss around osseointegrated implants occurs within the first 12 months after delivery of prostheses and stabilizes thereafter, so it is necessary to be careful of using dental implants for the first year after delivery of prostheses.

  • PDF

CLINICAL STUDY OF MAXILLOFACIAL PROSTHESES;OSSEOINTEGRATED IMPLANTS FOR MAXILLOFACIAL PROSTHESES (악안면 보철의 임상적 고찰;골내 매식술을 통한 보철적 회복에 관하여)

  • Min, Seung-Ki
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.23 no.5
    • /
    • pp.406-414
    • /
    • 2001
  • In recent decade, there has been a very rapid development in technical possibilities to provide patients with maxillofacial prostheses. Dr. Brenemark first introduced possibility of use of maxillofacial interosseous implant in patients with ablative tumor surgery in 1979. He did introduce the new type of maxillofacial implants system which widen the fixture flange on top of the bone. The advantages of fixed prostheses with implants were well known to various ways, easy to attach, keep clean prostheses, and not to disturb recipient bed. But there are some problems to install implants on maxillofacial regions, because mostly facial bone has very thin cortical bone and poor bone quality. It needs more retention between implant and bone which overcome that fault with fixture flange. To make maxillofacial prostheses, it should be understood general procedure of maxillofacial laboratory work. Ear and midface maxillofacial fabrication which include nose and eye defects will be described step by step.

  • PDF

COMPARISON OF MAXIMUM OCCLUSAL FORCES ON OSSEOINTEGRATED IMPLANT SUPPORTED FIXED PROSTHESES AND NATURAL TEETH (골유착성 임플랜트 지지 고정성 보철물과 자연치의 최대교합력 비교)

  • Kwon Young-Sook;Hwang Sun-Hong;Han Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.498-510
    • /
    • 2005
  • Purpose: The purpose of this study was to compare the maximum occlusal force implant prostheses to natural teeth. Material and Method: Fifty nine patients treated either with $Br{\aa}anemark$ implants and ITI implants during the recent ten years were involved in this study. The maximum occlusal force were measured with unilateral bite force recorder and dental prescale system. Results: 1. The maximum occlusal forces of the implant prostheses and natural teeth were not significantly different where measured with unilateral bite force recorder and dental prescale system. 2. The maximum occlusal forces were not significantly different between $Br{\aa}nemark$ implant and ITI implant prostheses. 3. The maximum occlusal forces of the implant prostheses had lower when compared with natural teeth during 1-6 months functional periods when measured with the unilareral bite force recorder(P<0.05) and 1-12 months functional periods when measured with the dental prescale system(P<0.05). After these periods there was not statistical significant difference between the implant prostheses and natural teeth. 4. The maximum occlusal forces of the wide diameter implant prostheses were higher than the maximum occlusal forces of the regular diameter implant prostheses when measured with dental prescale system(P<0.05), but there was no significant difference between the wide diameter and the regular diameter implant prostheses when measured with unilateral bite force recorder. 5. The maximum occlusal forces of the single implant prostheses were not significantly different with the splinting implants prostheses. 6. The maximum occlusal forces of the implant prostheses were not significantly different by age and sex. 7. There was significantly different between maximum occlusal forces measured with unilateral bite force recorder and dental prescale system(P<0.0001) but there was positive correlation(r=0.52. P<0.05). Conclusion: The maximum occlusal forces of the implant prostheses were not significantly different to natural teeth during clenching and unilateral maximum biting.

A Retrospective Study of Sintered Porous-surfaced Dental Implants in Restoring the Edentulous Posterior Mandible: Up to Eight Years of Functioning (하악 구치부에 식립한 sintered porous surfaced implants의 후향적 다기관 연구)

  • Kim, Woo-Sung;An, Kyung-Mi;Sohn, Dong-Seok;Jung, Heui-Seung;Shin, Im-Hee
    • The Journal of the Korean dental association
    • /
    • v.47 no.12
    • /
    • pp.823-829
    • /
    • 2009
  • Purpose : The aim of this study was to evaluate the survival rate of sintered porous-surfaced implants placed in the edentulous posterior mandibles, in relation to implant length and diameter, crown-to-implant ratio, and types of prostheses, for a maximum of eight years of functioning. Material and Methods : The study group consisted of 43 partially edentulous patients who visited Catholic University Hospital of Daegu and one private dental clinic. A total of 122 sintered porous-surfaced implants n $Endopore^{(R)}$ (Inn ova Life Sciences, Toronto, Ontario, Canada) -- were placed in the edentulous posterior mandibles, Two diameter sizes (4.1 mm and 5.0 mm) and four lengths (5.0 mm, 7.0 mm, 9.0 mm, and 12.0 mm) were used. One hundred and three implants were splinted and 21 implants were nonsplinted. The survival rates of the implants in relation to length, diameter, crown-to-implant ratio, and types of prostheses were investigated. Statistical data were analyzed using SPSS Win.Ver 14.0 software with the Chi-square test. Results : The survival rate of the 4.1mm diameter implants was 100% and 91.2% for the 5.0mm diameter implants. The survival rates of the implants of differing diameters were found to be statistically different (p=0.005). The survival rates of both the 5.0mm and 7.0 mm length implants were 100%. The survival rate of the 9.0mm length implants was 97.9% and for the 12.0mm length implants was 95.1%. There was no statistical difference in survival rates for the differing lengths of implants. Of the 103 prostheses that were splinted, the survival rate was 98.0%. The survival rate of splinted prostheses was higher than that of the non-splinted prostheses, but was found to be not statistically different. There were no failed cases when the crown-to-implant ratio was under 1.0. When the crown-to-implant ratio was between 1.0 and 1.5, the failure rate of the implants was 6.7%. No failure was recorded with the ratio range of 1.5 to 2.0. Relative to the crown-to-implant ratio of 1.0, the failure rates were statistically different (p=0.048). Discussion and Conclusion : The cumulative survival rate of the porous-surfaced implants placed in the edentulous posterior mandibles was 97.5%. Short porous-surfaced implants showed satisfactory results after a maximum of nine years of functioning in the edentulous posterior mandibles.

  • PDF

A within-subject comparison of short implants in the posterior region: retrospective study of up to 10 years

  • Segalla, Douglas Blum;Villarinho, Eduardo Aydos;Correia, Andre Ricardo Maia;Vigo, Alvaro;Shinkai, Rosemary Sadami Arai
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.3
    • /
    • pp.172-179
    • /
    • 2021
  • Purpose. This intra-patient retrospective study of up to 10 years evaluated the clinical success and risk factors of 6- and 8-mm long implants and their respective prostheses. Materials and Methods. The sample consisted of patients treated at a Military Polyclinic dental service, who received both 6- and 8-mm long tissue level implants in the posterior region of the same arch. Data were collected from the dental charts, clinical and radiographic exams, self-report of sleep bruxism, measurement of maximum occlusal force, and clinical crown-to-implant (C/I) ratio. Data were analyzed by descriptive and inferential statistics with univariate and hierarchical multivariate models, at the 0.05 significance level. Results. The 30 patients (27 women) had 85 implants and 83 prostheses. Two implants were lost before prosthesis installation (implant survival: 97.6%). Ten events of prosthetic complication (screw tightening loss) occurred in five patients (success rate: 87.9%) in a single moment. Only the variable C/I ratio had a significant effect for repairable prosthesis complication (P<.05). Conclusion. The results suggest that 6- and 8-mm long implants have similar long-term clinical success for implants and prostheses.

Effect of implant diameter and cantilever length on the marginal bone height changes and stability of implants supporting screw retained prostheses: A randomized double blinded control trial

  • Heba Ezzeldin Khorshid;Noha Ossama Issa;Amr Mohamed Ekram
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.3
    • /
    • pp.101-113
    • /
    • 2023
  • PURPOSE. This randomized controlled trial aimed to evaluate the effect of implants' two different diameters and cantilever lengths on the marginal bone loss and stability of mplants supporting maxillary prostheses. MATERIALS AND METHODS. Ninety-six implants were placed in sixteen completely edentulous maxillary ridges. Patients were randomly divided into two groups: Group A, implants were placed with a cantilever to anterior-posterior AP spread length (CL:AP) at a ratio of 1:3; Group B, implants were placed with a CL:AP at a ratio of 1:2. Patients were further divided into four sub-groups: Groups A1, A2, B1, and B2. Groups A1 and B1 received small diameter implants while Groups A2 and B2 received standard diameter implants. Bone height and stability measurements around each implant were performed at 0, 4, 8 and 24 months after definitive prostheses delivery. RESULTS. Statistical analysis of the mean implant stability and height values revealed an insignificant difference between Group A1 and Group A2 at all the different time intervals while significantly higher values in Group B1 in comparison with Group B2. Results also showed significantly higher values in Group A1 in comparison with Group B1 and an insignificant difference between Group A2 and Group B2 at all the different time intervals. CONCLUSION. It can be concluded that the use of small diameter implants placed with a CL:AP at a ratio of 1:3 provided predictable results and that the 1:2 CL:AP significantly induced more critical bone loss in the small diameter implants group, which can significantly reduce long term success and survival of implants

Tilted implants for implant-supported fixed hybrid prostheses: retrospective review

  • Woo-Hyun Seok;Pil-Young Yun;Na-Hee Chang;Young-Kyun Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.49 no.5
    • /
    • pp.278-286
    • /
    • 2023
  • Objectives: This review assessed the performance of implant-supported fixed hybrid prostheses in 21 patients who received a total of 137 implants between 2003 and 2010. The implants were evaluated for marginal bone resorption, complications, success rate, and survival rate based on their vertical angularity, type of bone graft, and measured implant stability. Materials and Methods: One-way ANOVA and chi-square tests were used to analyze the relationships among long-term evaluation factors and these variables. The mean initial bone resorption in the implant group with a vertical angle of more than 20° was 0.33 mm and mean final bone resorption was 0.76 mm. In contrast, the mean initial bone resorption in the implant group with a vertical angle of less than 10° was 1.19 mm and mean final bone resorption was 2.17 mm. Results: The results showed that mean bone resorption decreased with an increase in the vertical placement angle of the implants used in fixed hybrid prostheses, as well as in the group without additional bone grafts and those with high implant stability. The success rate of implants placed after bone grafting was found to be higher than those placed simultaneously. Conclusion: These results suggest that implant-supported fixed hybrid prostheses may be an effective treatment option for edentulous patients, and intentionally placing implants with high angularity may improve outcomes.

STABILITY CHANGES OF IMMEDIATELY LOADED AND DELAYED LOADED IMPLANTS IN EDENTULOUS MANDIBLE (하악 무치악에서 즉시하중과 지연하중간 임플랜트의 안정성 변화)

  • Jung, Hye-Eun;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra;Yi, Yang-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.2
    • /
    • pp.250-262
    • /
    • 2007
  • Statement of problem: It was reported high success rate of implant-supported fixed prostheses using with $5{\sim}6$ implants on anterior mandible. Recently, immediate loading protocol was focused to overcome disadvantages of classic 2-stage delayed loading protocol. Purpose: This clinical study was to evaluate stability changes with time of immediately loaded and delayed loaded implants in edentulous mandible and to compare stability changes with time according to implantation sites. Materials and methods: Five or six implants were placed on anterior mandible depending on the arch shape. The immediately loading group was consisted of 8 patients received their prostheses within $24{\sim}48$ hours after implantation. The delayed loading group was consisted of 8 patients received their definitive prostheses following classical prosthetic procedures after a healing period of 3 months. All patients were recalled every 6 months for check-up. The evaluations of radiographic examination, ISQ value measurement and recording of complication were done. To evaluate marginal bone level, intraoral periapical radiographs were taken with long cone paralleling technique. At every evaluation recall, all prostheses were removed and ISQ values were measured with OsstellTM on individual implants. Results: 1. None of implants was failed. All implants showed stable marginal bone levels and ISQ values. 2. Marginal bone level changes with time showed statistically significant difference between immediately loading group and delayed loading group (P<0.001). 3. ISQ value changes with time did not show statistically significant difference between immediately loading group and delayed loading group (P=0.079). ISQ value decreased with time in both groups, however, all implants showed stable ISQ value at 30 months-recall evaluation. 4. Marginal bone level changes with time did not show statistically significant differences among implantation sites (P=0.604). 5. ISQ value changes with time showed statistically significant differences among implantation sites (P=0.047). ISQ values of most posterior implants decreased with time comparing to other implants. Conclusion: Although the marginal bone level of the terminal abutment didn't different with the other implants, ISQ value of the terminal abutment was lower than that of the other implants. Therefore, further clinical evaluation would be needed in this point of view.

Three-dimensional finite element analysis on stress distribution of the mandibular implant-supported cantilever prostheses depending on the designs (임플란트 지지 하악 캔틸레버 보철물의 디자인에 따른 저작압 분산에 관한 삼차원 유한요소 분석)

  • Ban, Jae-Hyurk;Shin, Sang-Wan;Kim, Sun-Jong;Lee, Jeong-Yeol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.70-81
    • /
    • 2009
  • Statement of problem: The position and length of cantilever influence on the stress distribution of implants, superstructure and bone. In edentulous mandible, implant-supported cantilever prostheses that based 4 or 6 implants between mental foramens has been attempted. Excessive bite force loaded at cantilever prosthesis causes bone resorption and breakage of superstructure prosthesis around posterior implants. To complement the cantilever length of conventional prosthesis, In 1992, (McCartney) introduced "cantilever-rest-implant" and Malo reported "All-on-Four" in 2003. Purpose: Analyze and compare the stress distribution of conventional cantilever prostheses with rest implant and All-on-$Four^{TM}$ implant prostheses. Material and method: The external loads(300 N vertically, 75 N horizontally) are applied to first molar area. The stress value, stress distribution and aspect of stress dispersion are analyzed by three-dimensional finite element analysis program, ANSYS ver. 10.0. Results: 1. The rest implant and "All-on-Four" implant system are superior to conventional cantilever prostheses to reduce stress on the bone and the superstructure around implants. 2. The rest implant was of the greatest advantage to stress distribution on bone, implant and superstructure. 3. With same number of implants, distally tilted implants are preferred to conventional cantilever prostheses for reducing the length of cantilever.

A STUDY ON ORAL SENSORY FUNCTION IN THE IMPLANT-SUPPORTED PROSTHESES WEARERS (치과 임플랜트 보철 장착자의 구강 감각 기능에 관한 연구)

  • Jang, Kyoung-Soo;Kim, Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.1
    • /
    • pp.215-232
    • /
    • 1991
  • In this study, oral sensory function in the osseointegrated root form implant-supported prostheses wearers was estimated by measuring occlusal tactile perception threshold of thickness and sensibility threshold against lateral static loading, and comparing with normal dentition subjects and complete denture wearers group. Osseointegrated root form implants seemed to be restored in the sensation to some extent, and so, dental implants restored edentulous patients in a wide meaning. Conclusions were summarized as following. 1. Occlusal tactile perception threshold of thickness was highest in complete denture wearers group, following by implant-supported prostheses wearers group, normal dentition subjects group. 2. In the implant-supported prostheses wearers group, occlusal tactile perception threshold of opposing artificial teeth case was higher than of opposing natural or opposing implantsupported teeth case. 3. Sensibility threshold against lateral loading of complete denture wearers and implantsupported prostheses wearers group was higher than that of normal dentition subject group. 4. In the implant-supported prostheses group, sensibility threshold against lateral loading was not significantly different between upper and lower jaws. 5. In occlusal tactile perception threshold of thickness and sensibility threshold against lateral loading test, there was no regularity among values of each tooth, and no significant difference between anterior and posterior teeth as well.

  • PDF