• Title/Summary/Keyword: prostate

Search Result 1,217, Processing Time 0.031 seconds

Usability Assessment of Plan Transfer between TOMO HAD and Radixact : Planning Study (TOMO HDA와 Radixact 치료 계획 간 Transfer에 대한 유용성 평가 : Planning Study)

  • An, Ye Chan;Kim, Jong Sik;Kwon, Dong Yeol;Kim, Jin Man;Choi, Byeong Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.117-128
    • /
    • 2018
  • Purpose : To evaluate the usability of plan transfer between TOMO HD and Radixact, we compared the differences of dose in transferred plans by evaluating the dose of normal organ and target. TOMO HDA and Radixact. The completed plans were transferred each other and we compared the differences of dose by evaluating the DVH of each plans. Materials and Methods : We planned 4 different plans assuming the treatment of 2 cases in Head and Neck Cancer and 2 cases Prostate cancer. Each plan was designed so that 95 % of the prescription dose was irradiated over 99 % of the target volume, and the normal organ constraints dose was based on the SMC tolerance dose protocol. Each plan was transferred to each equipment and DVH(dose volume histogram) analysis of the transferred plans was compared and evaluated. Results : The Mean dose of CTV and GTV was increased and decreased in the transferred plans, but there was no significant differences. The target coverage of CTV and GTV was decreased in all cases of transferred plans from TOMO HAD to Radixact, and the change of CI and HI in CTV was within 0.1. Normal organ dose was increased in most cases when transferring from HAD to Radixact in both treatment plans. Conclusion : According to the results of this experiment, the target coverage was above the standard and the normal organ dose was almost same or decreased when transferring the plans from Radixact to HDA equipment. However the target coverage was reduced when transferring the plans from HDA to Radixact and there was an increase in dose in normal organs that could cause sever side effects such as Optic Chiasm ($D_{max}$1.38 Gy), Bladder ($D_{max}$3.07 Gy), Penile Bulb ($D_{max}$1.14 Gy). Therefore, it is necessary to pay attention to the dose change when transferring the plan and one-time transfer due to equipment inspection will be useful for efficient radiation therapy, but if the transferred treatment plans continue for several consecutive days, the treatment plan should be resumed.

  • PDF

Evaluation of the Jaw-Tracking Technique for Volume-Modulated Radiation Therapy in Brain Cancer and Head and Neck Cancer (뇌암 및 두경부암 체적변조방사선치료시 Jaw-Tracking 기법의 선량학적 유용성 평가)

  • Kim, Hee Sung;Moon, Jae Hee;Kim, Koon Joo;Seo, Jung Min;Lee, Joung Jin;Choi, Jae Hoon;Kim, Sung Ki;Jang, In-Gi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.177-183
    • /
    • 2018
  • Purpose : Volumetric Modulated Arc Therapy(VMAT) has the advantage of uniformly and precisely irradiating the tumor to the shape of the tumor while reducing the risk of radiation damage to normal tissues. such as brain cancer, head and neck cancer and prostate cancer, It is being used for treatment. The purpose of this study is to evaluate the usefulness of the Jaw-Tracking technique(JTT) in VMAT for brain and head and neck cancer. Materials and Methods : We selected eight patients with brain and head and neck cancer(4 Brain, 4 head and neck) who were treated with the VMAT treatment technique. Contouring information of the patient's tumor and normal organ was fused to the Rando phantom using the deformable registration of Velocity(Varian, USA). A treatment plan was developed using the Varian Eclipse(ver 15.5, Varian, USA) with the same patient actual beam parameters except for the use of jaw-tracking. As the evaluation index, the maximum dose and mean dose of target and OAR were compared and a portal dosimetry was performed for the treatment plan verification. Results : When using JTT, the relative dose of OAR decreased by 5.24 % and the maximum dose by 7.05 %, respectively, compared with the Static-Jaw technique(SJT). In the various OARs, the mean dose and maximum dose reduction ranges ranged from 0.01 to 3.16 Gy and from 0.12 to 6.27 Gy, respectively. In the case of the target, the maximum dose of GTV, CTV, PTV decreased by 0.17 %, 0.43 %, and 0.37 % in JTT, and the mean dose decreased by 0.24 %, 0.47 % and 0.47 %, respectively. Gamma analysis The JTT and SJT passing rates were $98{\pm}1.73%$ and $97{\pm}1.83%$ on the basis of 3 % / 3 mm, respectively. Comparing the doses of all OARs applied to the experiment, it was found that the use of JTT resulted in a significant decrease in dose due to additional jaw shielding besides MLC than SJT. Conclusion : In radiation therapy using VMAT treatment plan, we can apply JTT in the case of adjacent tumor and normal organs such as brain cancer and head and neck cancer, and in radiotherapy required large field and high energy caused increase leakage dose through MLC. It is considered that the target dose of PTV can be increased by lowering the dose of normal tissue surrounding the tumor.

  • PDF

Improvement of Radiosynthesis Yield of [11C]acetate ([11C]아세트산의 방사화학적 수율 증가를 위한 연구)

  • Park, Jun Young;Son, Jeongmin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.74-78
    • /
    • 2018
  • Purpose $[^{11}C]$acetate has been proved useful in detecting the myocardial oxygen metabolism and various malignancies including prostate cancer, hepatocellular carcinoma, renal cell carcinoma and brain tumors. The purpose of study was to improve the radiosynthesis yield of $[^{11}C]$acetate on a automated radiosynthesis module. Materials and Methods $[^{11}C]$acetate was prepared by carboxylation of grignard reagent, methylmagnesium chloride, with $[^{11}C]$$CO_2$ gas, followed by hydrolysis with 1 mM acetic acid and purification using solid phase extraction cartridges. The effect of the reaction temperature ($0^{\circ}C$, $10^{\circ}C$, $-55^{\circ}C$) and cyclotron beam time (10 min, 15 min, 20 min, 25 min) on the radiosynthesis yield were investigated in the $[^{11}C]$acetate labeling reaction. Results The maximum radiosynthesis yield was obtained at $-10^{\circ}C$ of reaction temperature. The radioactivities of $[^{11}C]$acetate acquired at $-10^{\circ}C$ reaction temperature was 2.4 times higher than those of $[^{11}C]$acetate acquired at $-55^{\circ}C$. Radiosynthesis yield of $[^{11}C]$acetate increased with increasing cyclotron beam time. Conclusion This study shows that radiosynthesis yield of $[^{11}C]$acetate highly dependent on reaction temperature. The best radiosynthesis yield was obtained in reaction of grignard reagent with $[^{11}C]$$CO_2$ at $-10^{\circ}C$. This radiolabeling conditions will be ideal for routine clinical application.

Literature review and future tasks necessary to establish of Korean Dietary Reference Intake for choline (콜린의 한국인 영양소 섭취기준 제정 검토를 위한 문헌 고찰 및 향후 과제)

  • Shim, Eugene;Park, Jae-Hee;Lee, Yunjung;Park, Eunju
    • Journal of Nutrition and Health
    • /
    • v.55 no.2
    • /
    • pp.211-226
    • /
    • 2022
  • Choline, an essential nutrient for humans, is required for the structural integrity of the cell membranes, methyl-group metabolism, synthesis of the neurotransmitter acetylcholine, synthesis of the membrane phospholipid components of the cell membranes, and the transport of lipids and cholesterol. Choline can be synthesized in the body, but it is insufficient to meet the daily requirements and hence it must be obtained through the diet. In the United States/Canada, Australia/New Zealand, Europe, China, and Taiwan, the adequate intake (AI) and tolerable upper intake level (UL) of choline have been established, while the establishment of the 2020 Dietary Reference Intakes for Koreans (KDRI) for choline was postponed due to the lack of a choline database for Korean foods and studies on the choline intake of Koreans. However, as part of the preparation work for the 2020 DRI revision and finalization, choline intake and the possibility of disease occurrence were verified through analysis of published data. The groundwork for the subsequent establishment of a choline DRI was laid through a literature search, evaluation, and review of the literature reported from 1949 up to 2019. This can be regarded as the culmination of this project. According to the results of randomized controlled trials (RCTs), cohort studies, case-control studies, and cross-sectional observational studies in humans, approximately 400-500 mg/day of choline intake was effective in preventing liver function damage (fatty liver), neural tube damage, cardiovascular disease, breast cancer, and cognitive function improvement. The same amount of choline intake, however, also correlated with the risk of prostate and colorectal cancer. At present, there is limited information available on choline intake and health outcomes, particularly for the Korean population. More human studies, including clinical trials on the requirements and the physiological benefits associated with dietary intake, are needed to establish the KDRI for choline.

Development of an Eye Patch-Type Biosignal Measuring Device to Measure Sleep Quality (수면의 질을 측정하기 위한 안대형 생체신호 측정기기 개발)

  • Changsun Ahn;Jaekwan Lim;Bongsu Jung;Youngjoo Kim
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.12 no.5
    • /
    • pp.171-180
    • /
    • 2023
  • The three major sleep disorders in Korea are snoring, sleep apnea, and insomnia. Lack of sleep is the root of all diseases. Some of the most serious potential problems associated with sleep deprivation are cardiovascular problems, cognitive impairment, obesity, diabetes, colitis, prostate cancer, etc. To solve these problems, the Korean government provided low-cost national health insurance benefits for polysomnography tests in July 2018. However, insomnia patients still have problems getting treated in terms of time, space, and economic perspectives. Therefore, it would be better for insomnia patients to be allowed to test at home. The measuring device can measure six biosignals (eye movement, tossing and turning, body temperature, oxygen saturation, heart rate, and audio). A gyroscope sensor (MPU9250, InvenSense, USA) was used for eye movement, tossing, and turning. The input range of the sensor was in 258°/sec to 460°/sec, and the data range was in the input range. Body temperature, oxygen saturation range, and heart rate were measured by a sensor (MAX30102, Analog Devices, USA). The body temperature was measured in 30 ℃ to 45 ℃, and the oxygen saturation range was 0% for the unused state and 20 % to 90 % for the used state. The heart rate measurement range was in 40 bpm to 180 bpm. The measurement of audio signal was performed by an audio sensor (AMM2742-T-R, PUIaudio, USA). The was -42 dB ±1 dB frequency range was 20 Hz to 20 kHz. The measured data was successfully received in wireless network conditions. The system configuration was consisted of a PC and a mobile app for bio-signal measurement and data collection. The measured data was collected by mobile phones and desktops. The data collected can be used as preliminary data to determine the stage of sleep and perform the screening function for sleep induction and sleep disturbances. In the future, this convenient sleep measurement device could be beneficial for treating insomnia.

Dosimetric Effect on Selectable Optimization Parameters of Volumatric Modulated Arc Therapy (선택적 최적화 변수(Selectable Optimization Parameters)에 따른 부피적조절회전방사선치료(VMAT)의 선량학적 영향)

  • Jung, Jae-Yong;Shin, Yong-Joo;Sohn, Seung-Chang;Kim, Yeon-Rae;Min, Jung-Wan;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.15-25
    • /
    • 2012
  • The aim of this study is to evaluate plan quality and dose accuracy for Volumetric Modulated Arc Therapy (VMAT) on the TG-119 and is to investigate the effects on variation of the selectable optimization parameters of VMAT. VMAT treatment planning was implemented on a Varian iX linear accelerator with ARIA record and verify system (Varian Mecical System Palo Alto, CA) and Oncentra MasterPlan treatment planning system (Nucletron BV, Veenendaal, Netherlands). Plan quality and dosimetric accuracy were evaluated by effect of varying a number of arc, gantry spacing and delivery time for the test geometries provided in TG-119. Plan quality for the target and OAR was evaluated by the mean value and the standard deviation of the Dose Volume Histograms (DVHs). The ionization chamber and $Delta^{4PT}$ bi-planar diode array were used for the dose evaluation. For treatment planning evaluation, all structure sets closed to the goals in the case of single arc, except for the C-shape (hard), and all structure sets achieved the goals in the case of dual arc, except for C-shape (hard). For the variation of a number of arc, the simple structure such as a prostate did not have the difference between single arc and dual arc, whereas the complex structure such as a head and neck showed a superior result in the case of dual arc. The dose distribution with gantry spacing of $4^{\circ}$ was shown better plan quality than the gantry spacing of $6^{\circ}$, but was similar results compared with gantry spacing of $2^{\circ}$. For the verification of dose accuracy with single arc and dual arc, the mean value of a relative error between measured and calculated value were within 3% and 4% for point dose and confidence limit values, respectively. For the verification on dose accuracy with the gantry intervals of $2^{\circ}$, $4^{\circ}$ and $6^{\circ}$, the mean values of relative error were within 3% and 5% for point dose and confidence limit values, respectively. In the verification of dose distribution with $Delta^{4PT}$ bi-planar diode array, gamma passing rate was $98.72{\pm}1.52%$ and $98.3{\pm}1.5%$ for single arc and dual arc, respectively. The confidence limit values were within 4%. The smaller the gantry spacing, the more accuracy results were shown. In this study, we performed the VMAT QA based on TG-119 procedure, and demonstrated that all structure sets were satisfied with acceptance criteria. And also, the results for the selective optimization variables informed the importance of selection for the suitable variables according to the clinical cases.

Analysis of Frequent Disease and Medical Expenses Structure of Patients Admitted in a Vaterans Hospital (일개 보훈병원 입원환자의 상병 및 진료비 구조분석)

  • Kim, Kyoung-Hwan;Lee, Sok-Goo;Kim, Jeong-Yeon
    • Journal of agricultural medicine and community health
    • /
    • v.30 no.1
    • /
    • pp.1-14
    • /
    • 2005
  • Objectives: This study attempts to analyze the length of hospital stay and expenses of frequent disease admitted in a Vaterans Hospital. Methods: Data was collected from January 1, 2001 to December 31, 2003 from the Claim records of 9,640 patients in a Vaterans Hospital. Results: The results were as follows: 1. In age & sex distribution, there was male 70.9%, female 29.1%, and 35.8% of them is 70 age group. Frequency by insurance program was Health insurance 78.1%, Medical aid 14.2%, no insurance 4.1%, others 3.6%. Distribution of each department was internal medicine 28.3%, orthopedic surgery 21.3%, surgery 16.6%, neurosurgey 7.1%, pediatrics 5.9%. Also, in the veterans group, male to female patient ratio was 99.3% male to 0.7% female, them over 70 years old was 51.6%, and them which live in daejeon was 43.5%. 2. In frequency of disease, there was gastroenteritis 4.8%, pneumonia 3.8%, cartaract 3.7%, cerebral infarct 3.2%, hyperplasia of prostate 3.0%. In frequency of korean standard classification of diseases, there was injury and poisoning and certain other consequences of external causes 17.1%, diseases of digestive system 16.1%, diseases of musculoskeletal system and connective tissue 13.9%, diseases of respiratory system 9.4%, diseases of genitourinary system 8.6%. Also, in veterans group, frequency of them was diseases of musculoskeletal system and connective tissue 19.4%, diseases of digestive system 16.8%, injury and poisoning and certain other consequences of external causes 15.7%, diseases of genitourinary system 9.7%, diseases of circuatory system 8.2%. 3. Average length of hospital stay was 29.0 days for total patients, 51.8 days for the veterans group, 15.7 days for the non-veterans one. Average total expenses was 3,669,579 won, the veterans group 7,263,877 won, the non-veterans one 1,560,333 won. The ratio of insurer to insuree was 55.2 : 44.8, the ratio of amount paid by patient in the veterans group 61.7%, in the non-veterans one 33.0%. 4. In items of medical expenses, fee for hospital accommodation was 34.7%, fee for medication 13.2%(injection 7.8%, drug 5.4%), fee for service 48.6%(physical therapy 26.3%, operation 9.7%, laboratory examination 5.2%, radiological examination 3.1%, etc), others 3.4%. In them for the veterans group, fee for physical therapy was 35.3%, fee for hospital accommodation 35.2%, fee for injection 6.2%, fee for operation 5.9%, for the non-veterans one, fee for hospital accommodation 35.7%, fee for operation 16.4%, fee for injection 11.4%, fee for laboratory examination 8.3%. 5. In the comparison of the frequency by Korean standard classification of diseases and distance between the hospital and home, the region under 21.5Km was more frequent in symptoms, signs an abnormal clinical and laboratory findings 56.0%, injury and poisoning and certain other consequences of external causes 55.6%, diseases of the eye and adnexa 52.9%, the one over 21.5Km was more frequent in neoplasms 57.4%, diseases of musculoskeletal system and connective tissue 55.9%, diseases of genitourinary system 53.5%.

  • PDF