• Title/Summary/Keyword: propylene/propane

Search Result 85, Processing Time 0.03 seconds

Condensation Heat Transfer Coefficients of Flammable Refrigerants on Various Enhanced Tubes

  • Park Ki-Jung;Jung Dongsoo
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.10
    • /
    • pp.1957-1963
    • /
    • 2005
  • In this study, external condensation heat transfer coefficients (HTCs) of six flammable refrigerants of propylene (RI270), propane (R290), isobutane (R600a), butane (R600), dimethylether (RE170), and HFC32 were measured at the vapor temperature of $39^{\circ}C$ on a 1023 fpm low fin and Turbo-C tubes. All data were taken under the heat flux of $32\~116\;and\;42\~142kW/m^2$ for the low fin and Turbo-C tubes respectively. Flammable refrigerants' data obtained on enhanced tubes showed a typical trend that external condensation HTCs decrease with increasing wall subcooling. HFC32 and DME showed up to $30\%$ higher HTCs than those of HCFC22 due to their excellent thermophysical properties. Propylene, propane, isobutane, and butane showed similar or lower HTCs than those of HCFC22. Beatty and Katz' correlation predicted the HTCs of the flammable refrigerants obtained on a low fin tube within a mean deviation of $7.3\%$. Turbo-C tube showed the best performance due to its 3 dimensional surface geometry for fast removal of condensate.

Selective Coordination of Silver Ions to Poly(styrene-b-(ethylene-co-butylene)-b-styrene) and its Influence on Morphology and Facilitated Olefin Transport

  • Lee, Dong-Hoon;Kang, Yong-Soo;Kim, Jong-Hak;Kang, Sang-Wook
    • Macromolecular Research
    • /
    • v.16 no.8
    • /
    • pp.676-681
    • /
    • 2008
  • The $\pi$-complex membranes of poly(styrene-b-(ethylene-co-butylene)-b-styrene) (SEBS) of two silver salts of $AgBF_4$ and $AgCF_3SO_3$ were prepared and tested for the separation of the propylene/propane mixtures. The Fourier-transform infrared (FT-IR) spectra of these complexes showed that the silver salts were dissolved in SEBS up to a silver mole fraction of 0.14, due to $\pi$-complexation between the aromatic C=C bonds of styrene blocks and silver ions. Above this solubility limit, ion pairs and high-order ionic aggregates began to form, so that silver salts were distributed unselectively in both the EB and PS blocks. The domain size of the PS blocks was enlarged up to this critical concentration with increasing silver concentration without structural transitions, as confirmed by small angle x-ray scattering (SAXS). These structural properties of the SEBS/silver salt complexes may explain the lower separation properties for propylene/propane mixtures compared to poly(styrene-b-butadiene-b-styrene)(SBS)/silver salt complex membranes.

Utilization of Iodine for the Enhanced Permeance of Facilitated Olefin Transport Nanocomposite Membrane (올레핀 촉진수송 나노복합체 분리막의 투과도 향상을 위한 iodine의 활용)

  • Choi, Yeji;Lee, Eun Yong;Kang, Sang Wook
    • Membrane Journal
    • /
    • v.24 no.6
    • /
    • pp.448-452
    • /
    • 2014
  • Nanocomposite membrane to show facilitated olefin transport was prepared for enhanced separation performance. Addtion of halogen molecules into PVP/AgNPs/ TCNQ nanocomposite membrane was expected to further polarize the surface of AgNPs for enhancing the separation performance. The formation of AgNPs and presence of iodine was confirmed by TEM and EDS analysis, respectively. The separation performance for propylene/propane mixture was compared with that of PVP/AgNPs/TCNQ nanocomposite membrane. The long-term stability of membrane was investigated with time.

Development of Pool Boiling Heat Transfer Correlation for Hydrocarbon Refrigerants (탄화수소계 냉매의 풀비등 열전달 상관식 개발)

  • Park Ki-Jung;Baek In-Cheol;Jung Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.3
    • /
    • pp.247-253
    • /
    • 2006
  • In this work, pool boiling heat transfer coefficients (HTCs) of hydrocarbon refrigerants are measured from a horizontal smooth tube of 19.0 mm outside diameter. Tested pure refrigerants are Propylene, Propane, Isobutane, Butane and Dimethylether (DME). The pool temperature was maintained at saturation temperature of $7^{\circ}C$ and heat flux was varied from $10kW/m^2$ to $80kW/m^2$ with an interval of $10kW/m^2$. Wall temperatures were measured directly by thermocouple hole of 0.5 mm out-diameter, 152 mm long and inserting ungrounded sheathed thermocouples from the side of the tube. Tested results show that HTCs of Propane, Propylene are 2.5%, 10.4% higher than those of R22 while those of Butane and Isobutane are 55.2%, 44.3% lower than those of R22 respectively. For pure refrigerants, new correlation can be applied to all of CFCs, HCFCS, HFCs, as well as hydrocarbons was developed. The mean deviation was 4.6%.

A Study on the Power Saving with the Use of LNG Cold Heat in a Cascade Refrigeration Cycle using Methane, Ethylene and Propylene as Refrigerants (메탄, 에틸렌 및 프로판 냉매를 활용한 다원 냉동 사이클에서 LNG 냉열을 활용한 동력 절감 방안에 대한 연구)

  • CHO, JUNGHO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.3
    • /
    • pp.302-306
    • /
    • 2020
  • In this study, computer simulation works using PRO/II with PROVISION V10.2 have been performed for a cascade refrigeration cycle using methane, ethylene and propane as refrigerants. LNG cold heat was also utilized in order to save the compression powers for the ethylene and propane refrigeration cycles. It was concluded that about 77% of compression power can be saved by using LNG cold heat through the exchanging heat with refrigerants. We could also know that the cold heat price contained in 1 ton of LNG is 16,155 won.

Polymer Electrolyte Membranes and their Applications to Membranes, Fuel Cells and Solar Cells

  • Kang, Yong-Soo
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.29-32
    • /
    • 2003
  • Polymer electrolyte membranes are developed for the applications to facilitated transport membranes, fuel cells and solar cells. The polymer electrolyte membranes containing silver salt show the remarkably high separation performance for olefin/paraffin mixture in the solid state; the propylene permeance is 45 GPU and the ideal selectivity of propylene/propane is 15,000. For fuel cell membranes, the effects of the presence and size of the proton transport channels on the proton conductivity and methanol permeability were investigated. The cell performance for dye-sensitized solar cells employing polymer electrolytes are measured under light illumination. The overall energy conversion efficiency reaches 5.44 % at 10 ㎽/$\textrm{cm}^2$, to our knowledge the highest value ever reported in the polymer electrolytes.

  • PDF

Chemical Modification of Wood with Alkylene Oxides, Vinylpirrolidinone and Furans:Effects on Dimensional Stabilization

  • Guevara, R.;Moslemi, A.A.
    • Journal of the Korean Wood Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.38-52
    • /
    • 1982
  • The effect of propylene oxide, butylene oxide, furan resin, and vinylpyrrolidinone in controlling wood dimensional stability have been examined. Wood in the green or ovendry condition was treated with various chemical treatments using a vacuum-pressure procedure, and treated specimens were tested for tangential sweelling, moisture gain, and changes in sorption hysteresis. Results' indicate that propylene oxide, and butylene oxide enhanced with the crosslin king agent trimethylol propane trimethacrylate and applied to ovendry wood were the most efficient chemical treatments in controlling tangential sweeling caused by liquid water or water vapor, and in reducing water vapor adsorption. The sorption behavior of treated wood as depicted by the ratios of sorption was "very favorable" in most instances. In the particular case of furan resin treatments, ratios of sorption were improved from 25 to 100 percent as compared to those of untreated wood.

  • PDF

Performance and heat transfer of an air conditioning system filled with hydrocarbon refrigerants (탄화수소 냉매를 사용한 냉방시스템의 성능 및 열전달 특성)

  • Jang, Yeong-Su;Kim, Min-Su;No, Seung-Tak
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.5
    • /
    • pp.713-723
    • /
    • 1997
  • Performance and heat transfer characteristics of an air conditioning system filled with hydro- carbon refrigerants are experimentally investigated. Single component hydrocarbon refrigerants (propane, isobutane, butane and propylene) and binary mixtures of propane/isobutane and propane/butane are considered as working fluids in the air conditioning system. Performances of each refrigerant are obtained at several compressor speeds and temperature levels of secondary heat transfer fluids. The cooling capacity and the coefficient of performance are obtained as test results. Heat transfer data of selected refrigerants are achieved from overall conductance measurement. Average heat transfer coefficients at different mass fluxes are shown and they are also displayed for different heat capacities of the system. Experimental results show that some hydrocarbon refrigerants have better characteristics than R22.

Experimental Study on Heat Transfer Characteristics of Evaporation using Propylene Refrigerant (프로필렌 냉매의 증발열전달 특성에 관한 실험적 연구)

  • 이호생;김재돌;정석권;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.5
    • /
    • pp.754-761
    • /
    • 2004
  • In this paper, evaporating heat transfer characteristics in the refrigeration and air-conditioning facilities were studied using the environmentally friendly refrigerants R-1270 (Propylene). R-290 (Propane). R-600a (Iso-butane) and HCFC refrigerant R-22 The test tube was surrounded by an annulus with water flowing counter to the refrigerant. The tube is copper. with an outside diameter of 12.7mm and the wall thickness of 1.315mm. The test results showed that the local evaporating heat transfer coefficients of hydrocarbon refrigerants were superior to that of R-22 and the maximum increasing rate of heat transfer coefficient was found in R-1270. The average evaporating heat transfer coefficient increased with the increase of the mass velocity and it showed the higher values in hydrocarbon refrigerants than R-22 Comparing the heat transfer coefficient of experimental results with that of other correlations. the presented results had agood agreement with the Kandlikar's correlation. This results form the investigation can be used in the design of heat transfer exchangers using hydrocarbons as the refrigerant for the air-conditioning systems.

Numerical Study of the Effects of Hydrocarbon Addition and Corresponding Chemical Kinetics on the Promotion of NO Oxidation in Nonthermal Plasma DeNOx Treatment (비열 플라즈마에 의한 NO의 산화에서의 탄화수소 첨가 효과와 그 반응역학에 대한 수치적 연구)

  • Shin, Hyun-Ho;Yoon, Woong-Sup
    • Journal of the Korean Society of Combustion
    • /
    • v.5 no.2
    • /
    • pp.37-50
    • /
    • 2000
  • In the present study, a systematic chemical kinetic calculations were made to investigate the augmentation of $NO-NO_2$ conversion due to the addition of various hydrocarbons (methane, ethylene, ethane, propylene, propane) in the nonthermal plasma treatment. It is included in the present conclusion that the reaction between hydrocarbon and oxygen radicals induced by electron collision, is believed to be a primarily process for triggering the overall NO oxidation and the eventual NOx reduction. Upon the completion of the initiating step, various radicals (OH, $HO_2$ etc.) successively are produced by hydrocarbon decomposition form the primary path of $NO-NO_2$ conversion. When the initiating step is not activated, hydrocarbon consumption rate appeared to be very low, thereby the targeted level of NO conversion can only be achieved by the addition of more input energy. Present study showed ethylene and propylene to have higher affinity with O radical under all conditions, thereby both of these hydrocarbons show very fast and efficient $NO-NO_2$ oxidation. It was also shown that propylene is superior to ethylene in the aspect of NOx removal.

  • PDF