• Title/Summary/Keyword: property damage

Search Result 1,064, Processing Time 0.026 seconds

Toxicity Evaluation of Asarum Sieboldii Extract for Human's Safety (인체안전성을 위한 족두리풀 천연추출물의 독성평가)

  • Kim, Young Hee;Jo, Chang Wook;Hong, Jin Young;Lee, Jeung Min;Kim, Soo Ji;Jeong, So Young
    • Journal of Conservation Science
    • /
    • v.33 no.4
    • /
    • pp.255-266
    • /
    • 2017
  • Chemically derived pesticides have been used to prevent biological damage to domestic cultural property. However, their use is gradually being restricted due to the harmful effects on the human body and environment. Therefore, there is a growing interest in the search for new antifungal biopharmaceuticals whose safety has been confirmed by toxicity evaluation through animal experiments. This paper presents methods of toxicity evaluation of natural biocides using Sprague-Dawley rats and New Zealand White (NZW) rabbits. Safety of the natural biocide extract of Asarum sieboldii was evaluated using single-dose oral and dermal toxicity tests in Sprague-Dawley rats, and eye and skin irritation tests in NZW rabbits. The extract has proven antimicrobial and insecticidal activities against wood-rotting fungi and termites. After single oral administration to rats, the $LD_{50}$ values were determined to be over 4,000 and 2,000 mg/kg for males and females, respectively. After single dermal administration to rats, the $LD_{50}$ values exceeded 10,000 mg/kg for both males and females. The extract was identified to be non-irritant to the rabbit eye, and only slightly irritant to the rabbit skin. In this study, we confirmed the safety of the A sieboldii extract through animal testing. Due to the harmfulness of humidifier disinfectants, focus is on the safety of chemical pesticides, and toxicity evaluation is suggested as the basic method for hazard evaluation.

A Study on the Protection for Original Technology and Improved Patent when Research Institutes or Universities Transfer their Research Outputs (출연연 및 대학에서 연구성과물의 기술이전 시 개량특허와 원천기술의 보호에 관한 검토 : H대학교와 D제약사의 신약후보물질 관련 개량특허 탈취논쟁여부를 중심으로 (대상판결: 서울중앙지방법원 2014.12.24. 선고 2013가합85597 판결))

  • Kang, Sun Joon;Kim, Min Ji;Won, Yoo Hyung;Oh, Keon Taek
    • Journal of Korea Technology Innovation Society
    • /
    • v.20 no.2
    • /
    • pp.313-333
    • /
    • 2017
  • As science and technology advanced, specialized and massive, development through mutual cooperation or research based on patent licensing such as material transfer contract, technology transfer contract etc are actively taking place to minimize or separate the cost and risk of R&D. In R&D, such mutual work can enjoy the merit of division of labor by effectively allocating resources and manpower to accomplish its goal. Inevitably, however, there are also many possibilities of disputes regarding the ownership and use of intellectual property rights resulting from such mutual/post-studies, or inventions upgraded by using prior patents. The case reviewed by this paper is noticeable regarding the recent trend of upgraded inventions. In the case, a pharmaceutical company conducted tests/assessments on the complete technology of patent owned by a university on the premise of transferring the technology, and then terminated the technology transfer contract due to reasons of toxicity. The university then filed a damage claim suit against the company for infringing the contract. This is a dispute case betw een a university which developed a potential ingredient for new medicine and a pharmaceutical company which agreed to transfer and receive the technological later on. Regarding the upgraded inventions of source patents, this case has many implications on the protection of prior patents, research contract, and research security to protect the accomplishment of research. This paper reviews the subject ruling and the protection of upgraded patents and source technologies. As critical notes, the paper also summarizes the major issues of case ruling to observe the standard of ruling patent infringement related to the extortion of upgraded patents. Then, through the ruling of the case above, the paper suggests implications and future strategies.

Correlation Analysis and Estimation Modeling Between Road Environmental Factors and Traffic Accidents (The Case of a 4-legged Signalized Intersections in Cheongju) (도로환경요인과 교통사고의 상관분석 및 사고추정모형 개발 (청주시 4지 신호교차로를 중심으로))

  • Park, Jeong-Sun;Kim, Tae-Yeong;Yu, Du-Seon
    • Journal of Korean Society of Transportation
    • /
    • v.25 no.2 s.95
    • /
    • pp.63-72
    • /
    • 2007
  • The purpose of this study is to develop a traffic characteristic analysis, a correlation analysis with the variables of traffic characteristics, and accident estimation models while recognizing the seriousness of the traffic accidents. The analyses deal with the 181 4-legged signalized intersections that accounted for 1,183 out of 3,115 accidents in Cheongju in 2004. After measuring ADT, intersection area, average lane width, elevation, and other items as independent variables and the number of traffic accidents, the traffic accident rate (accidents per million entering vehicles) and equivalent property damage only (EPDO) figures as dependent variables which are estimated as influencing signalized intersection accidents, the estimation models are developed using correlation analysis and multiple regression analysis. In the analysis of the number of traffic accidents, the model indicates an $R^2$ of 0.612, and five independent variables are taken as significant factors. In the analysis of traffic accident rates, the model indicates an $R^2$ of 0.304 and five significant factors, including intersection area and ADT. Also, for the analysis or the EPDO numbers, which coincides with understanding the seriousness of the traffic accidents and the traffic characteristic analysis, the model indicates an $R^2$ of 0.559, and four independent variables (ADT, main street average lane width, elevation, and speed limit) as significant factors.

Review of 2013 Major Medical Decisions (2013년 주요 의료 판결 분석)

  • Lee, Dong Pil;Jeong, Hye Seung;Lee, Jung Sun;Yoo, Hyun Jung
    • The Korean Society of Law and Medicine
    • /
    • v.15 no.1
    • /
    • pp.263-302
    • /
    • 2014
  • The court handed down meaningful rulings related to medical sectors in 2013. This paper presents the ruling that the care workers could be the performance assistants of the care-giving service although the duties of care worker are not included in the liability stipulated in the medical contract signed with the hospital for reason of clear distinction of duties between care workers and nurses within the hospital in connection with the contract which was entered into between the hospital and patients. In relation to negligence and causal relationship, the court recognized medical negligence associated with the failure to detect the brain tumor due to the negligent interpretation of MRI findings while rejecting the causal relationship with consequential cerebral hemorrhage. The court also recognized negligence based on the observation on the grounds of inadequate medical records in a case involving the hypoxic brain damage caused during the cosmetic surgery. In terms of the scope of compensation for damages, this paper presents the ruling that the compensation should be estimated based on causal relationship only in case the breach of the 'obligation of explanation' is recognized, however rejecting the reparation for de factor property damages in the form of compensation, and the ruling that the lawsuit could be instituted in case that the damages exceeded the agreed scope despite the agreement that the hospital would not be held responsible for any aftereffects of surgery from the standpoint of lawsuit, along with the ruling that recognized the daily net income by reflecting the unique circumstances faced by individual students of Korean National Police University and artists of Western painting. Many rulings were handed down with respect to medical certificate, prescription, etc., in 2013. This paper introduced the ruling which mentioned the scope of medical certificate, the ruling that related to whether the diagnosis over the phone at the issuance of prescription could constitute the direct diagnosis of patient, along with the ruling that required the medical certificate to be generated in the name of doctor who diagnosed the patients, and the ruling which proclaimed that it would constitute the breach of Medical Act if the prescription was issued to the patients who were not diagnosed. Moreover, this paper also introduced the ruling that related to whether the National Health Insurance Service could make claim to the hospitals for the reimbursement of the health insurance money paid to pharmacies based on the prescription in the event that the hospitals provided prescription of drugs to outpatients in violation of the laws and regulations.

  • PDF

An Analytical Study on Crack Behavior Inside Standard Compact Tension Specimen with Holes (구멍들을 가진 표준 CT 시험편 내에서의 크랙 거동에 대한 해석적 연구)

  • Lee, Jung Ho;Cho, Jae Ung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.6
    • /
    • pp.531-537
    • /
    • 2016
  • The damage and fracture of machine or structure are caused by the crack happened from the defect existed at the inside of material. The properties of crack propagation and growth characteristic must be considered because there are many cases at which these cracks are densely existed. Therefore, this study investigates the fracture property due to the position of crack and hole inside the standard compact tension (C. T.) specimen. When the concentrated load is applied eccentrically at the standard C. T. specimen, the fracture mechanical behavior due to the existence or non-existence and the position of hole near crack is investigated. As the result of analysis study, model 3 (in case of the distance of 2mm on the horizontal direction between the end part and hole as the specimen model existed with one hole near the crack) has the maximum deformation, stress and deformation energy of the most values among three models. As the distance between the crack and hole inside the specimen becomes nearer, the maximum stress becomes higher in cases of three models. Apart from the number of holes, it is seen that the maximum stress becomes higher near the crack when the hole exists near the crack inside the specimen. If the hole inside the machine or the mechanical structure is punctured by using the result of this study, it is thought that the occurred breakage or breakdown can be prevented by reducing the fracture stress happened at the specimen.

Experimental Study on the Flash Over Delay Effects according to the Prevention of Flame Spread between Composite Material Panels (복합자재의 패널 간 화염확산방지에 따른 플래시오버 지연 효과에 대한 실험적 연구)

  • Kim, Do-hyun;Cho, Nam-Wook
    • Fire Science and Engineering
    • /
    • v.31 no.2
    • /
    • pp.1-8
    • /
    • 2017
  • A sandwich panel is a composite material composed of a double-sided noncombustible material and insulation core which is used in the inner, outer walls, and roof structure of a building. Despite its excellent insulation performance, light weight and excellent constructability, a flame is brought into the inside of the panel through the joint between the panels, melting the core easily and causing casualties and property damage due to the rapid spread of flame. The current Building Law provides that the combustion performance of finishing materials for buildings should be determined using a fire test on a small amount of specimen and only a product that passes the stipulated performance standard should be used. This law also provides that in the case of finishing materials used for the outer walls of buildings, only materials that secured noncombustible or quasi-noncombustible performance should be used or flame spread prevention (FSP) should be installed. The purpose of this study was to confirm the difference between the dangers of horizontal and vertical fire spread by applying FSP, which is applied to finishing materials used for the outer walls of buildings limitedly to a sandwich panel building. Therefore, the combustion behavior and effects on the sandwich panel according to the application of FSP were measured through the construction to block the spread of flame between the panels using a full scale fire according to the test method specified in ISO 13784-1 and a metallic structure. The construction of FSP on the joint between the panels delayed the spread of flame inside the panels and the flash over time was also delayed, indicating that it could become an important factor for securing the fire safety of a building constructed using complex materials.

Experimental and Numerical Studies on the Failure of Curtain Wall Double Glazed for Radiation Effect (커튼월 이중 유리 외장재 파단에 대한 실험 및 수치해석 연구)

  • Nam, Jiwoo;Ryou, Hong-Sun;Kim, Dong-Joon;Kim, Sung-Won;Nam, Jun-Seok;Cho, Seongwook
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.40-44
    • /
    • 2015
  • National and international standards for curtain wall glass are focused on wind pressure and insulation performance, but disasters such as fires and earthquakes are not considered. Failure of curtain wall glass during a fire in a skyscraper increases the loss of lives and property due to the spread of fire. Therefore, the fire resistance of curtain wall glass should be investigated, and technology to prevent glass failure should be developed to prevent fire damage due to spreading fire. It is important to predict the starting point of cracks and the cause of glass failure to prevent it effectively using the limited water in a skyscraper. In this study, double glazed glass was exposed to a radiator in an experiment performed to analyze the thermal characteristics. The results show that glass that was not directly exposed to high temperature and pressure was broken. To identify this failure case, numerical analysis was performed. Three glass specimens were installed in an ISO 9705 room and exposed to radiation using a radiator, and a thermocouple was used to measure the temperature on the surface of the glass. Widely used double glazed glass was analyzed for weakness to fire.

Derivation of Safety Management Implications through Analysis of Major Elevator Failures (승강기 중대고장 분석을 통한 안전관리 시사점 도출)

  • Kim, Beom-Sang;Park, Poem
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.3
    • /
    • pp.23-29
    • /
    • 2020
  • As the duty to report and investigate major elevator failures has expanded due to the total amendment of the Elevator Safety Management Act in 2018, more important information on major elevator failures that have been partially identified has been collected. As of 2019, the number of elevators in Korea exceeded 700,000, making it the eighth-class elevator powerhouse in the world, but there is a trend of increasing casualties due to accidents and breakdowns. An Seung-gang-gi is a term that encompasses an elevator that moves vertically and an escalator that moves horizontally. It is an important means of transportation for most citizens that are encountered almost every day in daily life, and it is also necessary as a means of transportation that enables the construction of skyscrapers. And it seems that its importance will never diminish in the future. Major elevator failures are the main cause of dispatch when accumulating the number of 119 dispatches, and the frequency of occurrence is high. It's a shame. According to Heinrich's Law, 300 minor signs and danger phenomena precede, 29 minor accidents and 1 major accident. Accidents caused by elevators are increasing every year due to the increase in the number of installations, and the damage is threatening the valuable lives and property of users and workers in related fields due to fatal risks such as death and serious injury. Elevator safety management can achieve its purpose only when it is managed with the usual interests, awareness of safety, and full efforts of the users, workers, and the government concerned. This study was analyzed based on 2019 data notified to the Korea Elevator Safety Agency on major breakdowns improved after the revision of the Elevator Safety Management Act in 2018, and a total of 8,256 data were analyzed using the SPSS 21 version, a statistical analysis tool, to analyze the correlation with technical statistics. Proceeded. Through the analysis, it was possible to obtain preventive safety management data to prevent serious elevator safety accidents from occurring, and to derive meaningful implications that related safety management and maintenance can be effectively operated to prevent serious failures. In addition, through this analysis, we expect the development of related industries and legal and institutional improvement.

GIS-based Urban Flood Inundation Analysis Model Considering Building Effect (건물영향을 고려한 GIS기반 도시침수해석 모형)

  • Lee, Chang-Hee;Han, Kun-Yeun
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.3
    • /
    • pp.223-236
    • /
    • 2007
  • Recently in urban area flood damages increase due to local concentrated heavy rainfall. Even in the cities where stormwater drainage systems are relatively well established flood damage still occurs because of the capacity limitations of the existing stormwater drainage systems. When the flood exceeds the capacity limitation of the urban storm sewer system, it yields huge property losses of public facilities involving roadway inundation to paralyze industrial and transportation system of the city. To prevent such flood damages in urban area, it is necessary to develop adequate inundation analysis model which can consider complicated geometry of urban area and artificial drainage system simultaneously. The Dual-Drainage model used in this study is the urban inundation analysis model which combines SWMM with DEM based 2-dimensional surface flood inundation model. In this study, the dual drainage model has been modified to consider the effect of complex buildings in urban area. Through the simulation of time variable inundation process, it is possible to identify inundation alert locations as well as to establish emergency action plan for the residencial area vulnerable to flood inundation.

The Frost Heaving Characteristics of Subgrade Soils Using Laboratory Freezing System (실내동결시스템을 이용한 노상토의 동상 특성)

  • Shin, Eun-Chul;Ryu, Byung-Hyun;Park, Jeong-Jun
    • International Journal of Highway Engineering
    • /
    • v.12 no.2
    • /
    • pp.71-79
    • /
    • 2010
  • The influence of fines of the frost susceptibility of subgrade soils were established by laboratory freezing system test simulating closely the thermal conditions in the field. During the winter season, the climate is heavily influenced by the cold and dry continental high pressure. Because of siberian air mass, the temperature of January is $-6{\sim}-7^{\circ}C$ on average. This chilly weather generate the frost heaving by freezing the moisture of soil and damage potential of the road structure. In the freezing soil, the ice lenses increase the freeze portion of soil by absorbing the ground water with capillary action. However, the capillary characteristics differ from the sort of soil on the state of freezing condition. In the current design codes for anti-freezing layer, the thickness of anti freezing layer is calculated by freezing depth against the temperature condition. Therefore, they have a tendency of over-design and uniform thickness without the considerations of thermal stability, bearing capacity and frost susceptibility of materials. So, it is essential for studying the appropriateness and bearing capacity besides the seasonal and mechanical properties of pavement materials to take a appropriate and reasonable design of the road structure. In this Paper, the evaluation of frost susceptibility was conducted by means of the mechanical property test and laboratory freezing system apparatus. The temperature, heaving amount, heaving pressure and unfrozen water contents of soil samples, the subgrade soils of highway construction site, were measured to determine the frost susceptibility.