• Title/Summary/Keyword: program counter

Search Result 175, Processing Time 0.038 seconds

Evaluation of Image for Phantom according to Normalization, Well Counter Correction in PET-CT (PET-CT Normalization, Well Counter Correction에 따른 팬텀을 이용한 영상 평가)

  • Choong-Woon Lee;Yeon-Wook You;Jong-Woon Mun;Yun-Cheol Kim
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.1
    • /
    • pp.47-54
    • /
    • 2023
  • Purpose PET-CT imaging require an appropriate quality assurance system to achieve high efficiency and reliability. Quality control is essential for improving the quality of care and patient safety. Currently, there are performance evaluation methods of UN2-1994 and UN2-2001 proposed by NEMA and IEC for PET-CT image evaluation. In this study, we compare phantom images with the same experiments before and after PET-CT 3D normalization and well counter correction and evaluate the usefulness of quality control. Materials and methods Discovery 690 (General Electric Healthcare, USA) PET-CT equiptment was used to perform 3D normalization and well counter correction as recommended by GE Healthcare. Based on the recovery coefficients for the six spheres of the NEMA IEC Body Phantom recommended by the EARL. 20kBq/㎖ of 18F was injected into the sphere of the phantom and 2kBq/㎖ of 18F was injected into the body of phantom. PET-CT scan was performed with a radioacitivity ratio of 10:1. Images were reconstructed by appliying TOF+PSF+TOF, OSEM+PSF, OSEM and Gaussian filter 4.0, 4.5, 5.0, 5.5, 6.0, 6,5 mm with matrix size 128×128, slice thickness 3.75 mm, iteration 2, subset 16 conditions. The PET image was attenuation corrected using the CT images and analyzed using software program AW 4.7 (General Electric Healthcare, USA). The ROI was set to fit 6 spheres in the CT image, RC (Recovery Coefficient) was measured after fusion of PET and CT. Statistical analysis was performed wilcoxon signed rank test using R. Results Overall, after the quality control items were performed, the recovery coefficient of the phantom image increased and measured. Recovery coefficient according to the image reconstruction increased in the order TOF+PSF, TOF, OSEM+PSF, before and after quality control, RCmax increased by OSEM 0.13, OSEM+PSF 0.16, TOF 0.16, TOF+PSF 0.15 and RCmean increased by OSEM 0.09, OSEM+PSF 0.09, TOF 0.106, TOF+PSF 0.10. Both groups showed a statistically significant difference in Wilcoxon signed rank test results (P value<0.001). Conclusion PET-CT system require quality assurance to achieve high efficiency and reliability. Standardized intervals and procedures should be followed for quality control. We hope that this study will be a good opportunity to think about the importance of quality control in PET-CT

  • PDF

Landslide Susceptibility Analysis in Jeju Using Artificial Neural Network(ANN) and GIS (인공신경망기법과 GIS를 이용한 제주도 산사태 취약성분석)

  • Quan, He-Chun;Lee, Byung-Gul;Cho, Eun-Il
    • Journal of Environmental Science International
    • /
    • v.17 no.6
    • /
    • pp.679-687
    • /
    • 2008
  • In this study, we implemented landslide distribution of Jeju Island using ANN and GIS, respectively. To do this, we first get the counter line from 1:2,5000 digital map and use this counter line to make the DEM. for the evaluate the land slide susceptibility. Next, we abstracted slop map and aspect map from the DEM and get the land use map using ISODATA classification method from Landsat 7 images. In the computation processes of landslide analysis, we make the class to the soil map, tree diameter map, Isohyet map, geological map and so on. Finally, we applied the ANN method to the landslide one and calculated its weighted values. GIS results can be calculated by using Acrview program and produced Jeju landslide susceptibility map by usign Weighted Overlay method. Based on our results, we found the relatively weak points of landslide ware concentrated to the top of Halla mountains.

Assessment of University Food Service by Students in Daejeon Area (대전지역 대학생들에 의한 대학 급식소의 급식평가)

  • 박상욱;하귀현
    • The Korean Journal of Food And Nutrition
    • /
    • v.11 no.5
    • /
    • pp.528-535
    • /
    • 1998
  • This study was conducted to provide some basic information for promoting efficiency in university food services. Subjects were 309 students of A, B and C university. The survey was done by questionaires, and the data were analyzed by SAS program. The quantity and nutritional values of food was evaluated as appropriate but temperature and freshness of food, use of seasonal food, variety of menu were indicated as unsatisfactory. Male students marked lower points on the price but female students gave lower scores for variety of menu and use of seasonl food. Employee hygiene fast service and neatness and kindness of workers were evaluated as appropriate but food sanitation and cleanness of dishes were indicated as unsatisfactory. A and B university students scored low marks on food sanitation. Female students scored higher marks on the employee's neatness. Arrangement of tables and chairs, location of returning utensils, location of counter use of menu board and ventilation facilities were scored as average but interior decoration and heating facilities were scored as low level. Students of a school scored low mark on the arrangement of tables, location of counter, heating facilities and interior decoration but students of B school scored low mark on the use of menu board. Calmness and comfortableness of dining hall was unsatisfactory but location of dining hall, serving time and waiting time were evaluated as appropriate. In conclusion improvements for temperature and freshness of food, use of seasonal food, variety of menu, food sanitation, cleanness of dishes, interior decoration, heating facility and resting area were indicated as necessary.

  • PDF

Reuse Information based Thrashing Resistant Cache Management Scheme

  • Sim, Gyu Yeon;Kim, Cheol Hong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.3
    • /
    • pp.9-16
    • /
    • 2017
  • In recent computing systems, LRU replacement policy has been widely used because it can be simply implemented and applicable to most programs. However, if the working set size of the program is bigger than the actual cache size, LRU replacement policy may occur thrashing problem. Thrashing problem means that cache blocks are consistently replaced without re-referencing in the cache. This paper proposes a new cache management scheme to solve the thrashing problem in the second-level cache. The proposed scheme measures per set reuse frequency using EAF structure to find thrashing sets. When the cache miss occurs, it tests whether the address of the missed block is stored or not. If the address of the missed block is stored, it means that the recently evicted block is re-requested, so the reuse frequency is predicted high. In this case, the corresponding counter of the set is increased. When the counter value is bigger than the threshold value, we assume that the corresponding set shows high reuse frequency. The proposed scheme assigns the set with high reuse frequency to the additional small size cache to keep the blocks in the cache for a long time. Our experimental results show that the proposed scheme improves the IPC by 3.81% on average.

Development of Measurement System for Industrial Transportable Gamma Ray CT (이동 형 산업용 단층측정 장치를 위한 감마선 검출시스템 개발)

  • Kim, Jong-Bum;Jung, Sung-Hee;Moon, Jin-Ho
    • Journal of Radiation Industry
    • /
    • v.6 no.3
    • /
    • pp.231-237
    • /
    • 2012
  • This paper introduces a gamma-ray measurement system for a transportable tomography which is applicable for an industrial process diagnosis. The gamma-ray measurement system consists of pulse mode operating 72 channel CsI detectors, main AMP-pulse shaper, single channel analyzer, counter and control PC. The CsI crystal is coupled with a PIN diode which is connected to an amplifier and pulse shaper. For a compact design, the amplifier and pulse shaping circuit are included in a single package. 36 sets of CsI detectors are connected to a multi-channel counter through single channel analyzers. A computer controls and collects data from two multi-channel counters. This configuration results in 72 channel counting system in total. The CT rotator and radiation measurement system are controlled by a PC with LabVIEW program. Tomographic data were measured for a phantom by the measurement system and transportable gamma-ray CT. From the experimental data image reconstructions were performed by ML-EM algorithm. The result showed that the CsI detector system can be a suitable component for transportable gamma-ray CT system.

Characterization of Aerosol Concentration during Severe Asian Dust Period at Busan, Korea in 20 March 2010 (2010년 3월 20일 부산지역에 발생한 극심한 황사의 에어로솔 농도 분포 특성)

  • Jung, Woon-Seon;Park, Sung-Hwa;Lee, Dong-In;Kang, Deok-Du;Kim, Dongchul
    • Journal of Environmental Science International
    • /
    • v.23 no.2
    • /
    • pp.275-289
    • /
    • 2014
  • Asian dust (or yellow sand) occurring mainly in spring in East Asia is affected by the distribution of weather systems. This study was performed to investigate the characteristics of suspended particulate for Asian dust at Busan, Korea in 20 March 2010, which was one of the extreme case for the last 10 years. There was used the data of weather chart, satellite, automatic weather system (AWS), $PM_{10}$, laser particle counter (LPC), and backward trajectories model. In synoptically, the high pressure was located in the northwestern part and low pressure was located in the northeastern part of Korea. The strong westerly winds from surface to upper layer makes it possible to move air masses rapidly. Air masses passing through Gobi Desert in Mongolia and Inner Mongolia plateau covered the entire Korean peninsula. As the results of aerosol analysis, $PM_{10}$ concentration at Gudeok mountain in Busan was recorded $2,344{\mu}g/m^3$ in 2300 LST 20 March 2010 and their concentration was markedly increased at coarse mode particle. In surface condition, westerly wind about 3 ~ 5 m/s was dominant and small particles of $0.3{\sim}0.5{\mu}m$ were distributed on the whole. In heavy metal components analysis, the elements from the land was predominated.

The Study on Medication Management in Small-to-Medium Sized Workplaces and the Level of Awareness about 'Separation of Prescribing and Dispending' (중소규모 사업장의 의약품 관리실태 및 의약분업에 대한 근로자의 인식도)

  • Kim, Young-Im;Jee, Ju-Ok;Yun, Soon-Nyung;Jung, Hye-Sun;Choi, Sook-Ja;Lee, Jung-Ok;Lee, Hyun-Jung
    • Research in Community and Public Health Nursing
    • /
    • v.11 no.2
    • /
    • pp.513-525
    • /
    • 2000
  • This study was to investigate medication management and the level of awareness about separation of prescribing and dispending at small-to-medium sized workplaces which have less than 300 employees in Korea. The data were collected by questionnaires from May to June in 2000. The number of subjects were 127 workplaces and 130 employees. The SAS PC Program was used for the descriptive statistics. The results are as follows; 1. The over the counter(OTC) drug was provided sufficiently(91.1 %). but medication management was not performed systematically. 2. On drug-providing rate and drug-using rate, the latter was high in the workplace and Health care management's nurses consume all of the over the counter drug provided. 3. When the separation of prescribing and dispending starts, employees shall be medically examined, treated and prescribed by physicians and drugs shall be dispended by pharmacists. It is necessary to make it possible to visit health care institutions whenever they want to. (eg. lunch time or after work) They should change their drug-dependent behaviour. We should focus on strengthening Health Promotion Program to prevent disease by making habitual of health promotion behaviour.

  • PDF

Flutter Analysis of Annular Cascades in Counter Rotation

  • Nishino, R.;Namba, M.
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.813-824
    • /
    • 2004
  • The paper studies the effect of neighboring blade rows on flutter characteristics of cascading blades. For this purpose the computation program to calculate the unsteady blade loading based on the un-steady lifting surface theory for contra-rotating annular cascades was formulated and coded. Then a computation program to solve the coupled bending-torsion flutter equation for the contra-rotating annular cascades was also developed. Some results of the flutter analysis are presented. The presence of the neighboring blade row gives rise to significant change in the critical flutter condition when the main acoustic duct mode is of cut-on state.

  • PDF

The Effects of Exercise Intervention Program Based on the Stage of Change on Obese Children in Elementary School (초등학교 비만아동을 대상으로 행위변화단계를 적용한 운동중재 프로그램의 효과)

  • Lee, Yeun-Hee;Jung, Hye-Sun
    • Journal of the Korean Society of School Health
    • /
    • v.18 no.2
    • /
    • pp.73-84
    • /
    • 2005
  • Purpose : This study was designed to apply a "stage of change" exercise intervention program to obese children in elementary school and to examine its effects on their BMI. stage of change. process . and self-efficacy in exercise. Methods : The experimental group included 64 children in the fourth . fifth and sixth grades. from one elementary school. whose BMI was in the H5th percentile or more for their age groups. The control group had 6 1 students from a different one elementary school whose conditions were the same as those of the experimental group. Results: After the stage of change exercise intervention was applied, the BMI of the experimental group decreased by a significant enough degree to conclude that the program was effective in decreasing BMI. After the application of the program. the experimental group experienced a significant increase in their helping relationships. counter-conditioning . reinforcement management and stimulus control compared 10 the control group. After the program. self-efficacy in terms of exercise increased significantly in the experimental group. Conclusion: A stages of change exercise intervention program has been shown to engage individual students and encourage them 10 maintain a higher fitness level that promote s self-efficacy in exercise and therefore moves them towards healthier lifestyles. Moreover. the study proved that a significant reduction of BMI was achieved by the stages of change exercise intervention program.

The Design of High Speed Processor for a Sequence Logic Control using FPGA (FPGA를 이용한 시퀀스 로직 제어용 고속 프로세서 설계)

  • Yang, Oh
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.12
    • /
    • pp.1554-1563
    • /
    • 1999
  • This paper presents the design of high speed processor for a sequence logic control using field programmable gate array(FPGA). The sequence logic controller is widely used for automating a variety of industrial plants. The FPGA designed by VHDL consists of program and data memory interface block, input and output block, instruction fetch and decoder block, register and ALU block, program counter block, debug control block respectively. Dedicated clock inputs in the FPGA were used for high speed execution, and also the program memory was separated from the data memory for high speed execution of the sequence instructions at 40 MHz clock. Therefore it was possible that sequence instructions could be operated at the same time during the instruction fetch cycle. In order to reduce the instruction decoding time and the interface time of the data memory interface, an instruction code size was implemented by 16 bits or 32 bits respectively. And the real time debug operation was implemented for easy debugging the designed processor. This FPGA was synthesized by pASIC 2 SpDE and Synplify-Lite synthesis tool of Quick Logic company. The final simulation for worst cases was successfully performed under a Verilog HDL simulation environment. And the FPGA programmed for an 84 pin PLCC package was applied to sequence control system with inputs and outputs of 256 points. The designed processor for the sequence logic was compared with the control system using the DSP(TM320C32-40MHz) and conventional PLC system. The designed processor for the sequence logic showed good performance.

  • PDF