• Title/Summary/Keyword: program counter

Search Result 175, Processing Time 0.025 seconds

Development of Program counter through the optimization of RSFQ Toggle Flip-Flop (RSFQ Toggle Flip-Flop 회로의 최적화를 통한 Program Counter의 개발)

  • Baek Seung Hun;Kim Jin Young;Kim Se Hoon;Kang Joon Hee
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.1
    • /
    • pp.17-20
    • /
    • 2005
  • We has designed, fabricated, and measured a Single flux quantum (SFQ) toggle flip-flop (TFF). The TFF is widely used in superconductive digital electronics circuits. Many digital devices, such as frequency counter, counting ADC and program counter be used TFF Specially, a program counter may be constructed based on TFF We have designed the newly TFF and obtained high bias margins on test. In this work, we used two circuit simulation tools, WRspice and Julia, as circuit optimization tools. We used XIC for a layout tool. Newly designed TFF had minimum bias margins of +/- $37\%$ and maximum bias margins of +/-$37\%$(enhanced from +/- $37\%$). The designed circuits were fabricated by using Nb technology The test results showed that the re-optimized TFF operated correctly on 100kHz and had a very wide bias margins of +/- $53\%$.

A Study on the Counter Program of the Radiation Detector Using 8051 Micro-controller (8051 마이크로 콘트롤러를 이용한 휴대용 방사능 측정기의 카운터 프로그램 연구)

  • Kim, Yong-Duk;Park, Se-Kwang
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.228-236
    • /
    • 1997
  • Radioactive materials need to control, measure and protect precisely the overflow because they are dangerous. In this paper, GM-counter type radiation detector system, that can precisely measure the quantity of radioactivity using improved counting program is designed and program that can store and transfer the counted data is studied. The manufactured system, counting system of GM-counter type radiation detector, and counter program can be utilized to measure them at various methods in an atomic power plant and research centers.

  • PDF

Program Development for Design of Counter-flow Cooling Tower (향류형 냉각탑의 기본설계 프로그램 개발)

  • Ko, Kwang-Ho;In, Jong-Soo;Oh, Tae-Il
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.7 no.4
    • /
    • pp.383-389
    • /
    • 2004
  • This paper is to develop the program for sizing of a counter-flow cooling tower. Air flow, air exit tmperature, fan power are calculated from design coditions of cooling tower by using this program. The basic equations and solutions of the heat transfer and pressure drop of cooling tower are descrived and the algorithm development for design of cooling tower is performed. The variation of fan power of cooling tower in acoording to variation of cell area and fill height is performed by using this program. This result shows that the optimal design for install and running cost of cooling tower can be performed by using this program.

  • PDF

The Application of New Calibrator[I-125]Set for Equipment Quality Management (장비정도관리에 Calibrator[I-125] Set 적용)

  • Kim, Ji-Na;An, Jae-seok;Won, Woo-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.108-111
    • /
    • 2015
  • Purpose Lately, in accordance with the increasing interest about Healthcare accreditation program and International laboratory accreditation scheme, requirements about the instrument quality management are gradually taking shape. In nuclear medicine In vitro laboratory, the most typical instruments are multi detector gamma counter and automatic dispensing system. Each laboratory continue with the quality control adequate for circumstances. The purpose of this study is to application and establish the new Calibrator[I-125]Set which is efficient at standardization of equipment quality management. Materials and Methods Deviation between detectors were measured with 12 solid samples of the Calibrator[I-125]Set. their activities differ from each other by less than 1%. Multi detector gamma counters are GAMMA-10;Shinjin medics. Inc, Goyansi, Korea(Gamma counter A), SR300;Stratec biomedical systems AG, Gewerbestr, Germany(Gamma counter B) and COBRA II; Packard Instrument Co. Inc, Meriden, USA(Gamma counter C). Evaluation of two automatic dispensing system used A, B liquid tracer of the Calibrator[I-125]Set. After dispensing and counting, calculated using the ratio of the measured value and proposed value. We used solution A for 20, 25ul and solution B for 50, 100ul. Method of data analysis and reference range was provided by kit documentation. Furthermore, we could calculate our counter efficiency indirectly. Results The CV(%) of measured values by Gamma counter A, B, C are 0.34, 0.70, 1.30. Calculated value are 1.05314, 2.10419, 4.08485. Provided reference range is less than 3. A dispensing system's calculated values are 0.986, 0.989, 1.023, 1.017 and B are 0.874, 0.725, 1.021, 0.904. Provided reference range is from 0.95 to 1.05. Also, counter's efficiency are 74.18, 72.79, 74.32% at counter A, B, C and efficiency of the one detector counter is 79.26%. Conclusion If using this Calibrator[I-125]Set after verifying whether quality assurance, is applicable to equipment quality management on behalf of the role of gold standard.

  • PDF

Counter weight design for a W/V type reciprocating air compressor (W형 및 V형 왕복동 공기압축기의 평형추 설계)

  • 김영철;성세제;김영주;최상규
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.227-233
    • /
    • 2002
  • For the purpose of high outlet pressure, compactness and low vibration and noise, modem reciprocating air compressors are tend to have a multi-stage W-type or V-type cylinder arrangement. An effective counter weight calculation method is presented for reducing the inertia forces of the compressor. This calculation method is using the complex representation and verified its validity. A design program for the counter weight of W-type or V-type air compressor was presented to the manufacturer, A designed counter weight was attached to the W-type or V-type air compressor. Vibration test results gave us improved performance.

  • PDF

Design And Implementation of X-Band Frequency Synthesizer for Radar Transceiver (Radar Transceiver용 X-밴드 PLL 주파수 합성기 설계 및 제작)

  • Lee, Hyun-Soo;Park, Dong-Kook
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.137-140
    • /
    • 2005
  • A frequency synthesizer of 10 GHz $\sim$ 11 GHz for FMCW radar is designed and implemented by the form of indirect frequency synthesizer of a single loop structure. The synthesizer uses a high speed digital PLL chip. It is difficult to divide directly by using a program counter of PLL chip because the output frequency of VCO is 10 GHz $\sim$ 11 GHz, so we lower the frequency to 625 MHz $\sim$ 687.5 MHz by using a prescaler, and then divide the frequency by the program counter. The output frequency sweep of VCO from 10 GHz to 11 GHz is measured.

  • PDF

Development of X-band frequency synthesizer for radar transceiver (레이더 송수신기용 X 밴드 주파수 합성기 개발)

  • Lee, Hyun-Soo;Park, Dong-Kook;Lee, Su-Tea;Kim, Jin-Young
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.208-209
    • /
    • 2005
  • A frequency synthesizer of 10 GHz ${\sim}$ 11 GHz for FMCW radar is designed and implemented by the form of indirect frequency synthesizer of a single loop structure. The synthesizer uses a high speed digital PLL chip. It is difficult to divide directly by using a program counter of PLL chip because the output frequency of VCO is 10 GHz ${\sim}$ 11 GHz, so we lower the frequency to 625 MHz ${\sim}$ 687.5 MHz by using a prescaler, and then divide the frequency by the program counter. The output frequency sweep of VCO from 10 GHz to 11 GHz is measured.

  • PDF

Study on the Dynamic Behaviors of Wave Energy Converter by using RecurDyn (리커다인을 이용한 파력발전기 동적거동 연구)

  • Sohn, Jeong-Hyun;Jun, Chul-Woong;Kim, Min-Soo
    • Journal of Power System Engineering
    • /
    • v.21 no.2
    • /
    • pp.35-40
    • /
    • 2017
  • In this study, the multi-body dynamics model for a wave energy converter is established. The equations of motions for the mechanical parts of the wave energy converter are derived to analyze the dynamic behavior. A spring method with the same performance as the counter weight method is proposed. The counter weight method and spring method are analyzed for evaluating the performance of the wave energy converter. RecurDyn program which is a kind of commercial multi-body dynamics program is used to perform the dynamic simulation of the wave energy converter.

The Design of A Program Counter Unit for RISC Processors (RISC 프로세서의 프로그램 카운터 부(PCU)의 설계)

  • 홍인식;임인칠
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.7
    • /
    • pp.1015-1024
    • /
    • 1990
  • This paper proposes a program counter unit(PCU) on the pipelined architecture of RISC (Reduced Instruction Set Computer) type high performance processors, PCU is used for supplying instruction addresses to memory units(Instruction Cache) efficiently. A RISC processor's PCU has to compute the instruction address within required intervals continnously. So, using the method of self-generated incrementor, is more efficient than the conventional one's using ALU or private adder. The proposed PCU is designed to have the fast +4(Byte Address) operation incrementor that has no carry propagation delay. Design specifications are taken by analyzing the whole data path operation of target processor's default and exceptional mode instructions. CMOS and wired logic circuit technologic are used in PCU for the fast operation which has small layout area and power dissipation. The schematic capture and logic, timing simulation of proposed PCU are performed on Apollo W/S using Mentor Graphics CAD tooks.

  • PDF

On the Conceptual Design of the SIMD Vector Machine Attachable to SISD Machine (SISD 머신에 부착 가능한 SIMD 벡터 머신의 개념적 설계)

  • Cho Young-Il;Ko Young-Woong
    • The KIPS Transactions:PartA
    • /
    • v.12A no.3 s.93
    • /
    • pp.263-272
    • /
    • 2005
  • The addressing mode for data is performed by the software in yon Neumann-concept(SISD) computer a priori without hardware design of an address counter for operands. Therefore, in the addressing mode for the vector the corresponding variables as much as the number of the elements should be specified and used also in the software method. This is because not for operand but only for an instructions, quasi PC(program counter) is designed in hardware physically. A vector has a characteristic of a structural dimension. In this paper we propose to design a hardware unit physically external to the CPU for addressing only the elements of a vector unit with the structure and dimension. Because of the high speed performance for a vector processing it should be designed in the SIMD pipeline mechanics. The proposed mechanics is evaluated through a simulation. Our result shows $12\%$ to $30\%$ performance enhancement over CRAY architecture under the same hardware consideration(processing unit).