• 제목/요약/키워드: profile beams

검색결과 107건 처리시간 0.027초

Mach-Zenhder 간섭계를 이용한 아크방전 중의 전자밀도 측정 (Electron density measurment in arc discharge using Mach-Zenhder interferometer)

  • 조주현;노영수;이홍식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1898-1900
    • /
    • 1996
  • The Laser aided diagnostic method makes it possible to diagnose plasma characteristics which have never been done by other one. The aim of this study is to measure the electron density profile of an arc plasma by Mach-Zenhder interferometer. The two laser beams (He-Ne and Argon Lasers), which are different in wavelength, pass across an arc plasma and meet a change of refractivity which makes fringe shifts. From this effects we could find densities of electron and neutral particle.

  • PDF

탄소강 환봉의 레이저 표면변태경화 특성에 관한 연구 (II) - 빔 프로파일 차이에 따른 레이저 표면변태경화 특성 비교 - (Study on Characteristics of Laser Surface Transformation Hardening for Rod-shaped Carbon Steel (II) - Comparison of Characteristics on Laser Surface Transformation Hardening as a Difference on Beam Profile -)

  • 김종도;강운주
    • Journal of Welding and Joining
    • /
    • 제25권3호
    • /
    • pp.85-91
    • /
    • 2007
  • The conventional study on the laser surface transformation hardening has been carried out with a beam of the specified shape and uniform power-intensity distribution in order to ensure the uniformity of the hardening depth. Two types of beams - the circular gaussian beam and rectangular beam of the uniform power-intensity distribution were used in this study. we were supposed to optimize the process parameters and to compare the hardening results with two optics respectively. As a result, the hardness distribution of the hardened zone was similar in both cases and the hardened phase by the rectangular beam was denser than that by the circular gaussian beam.

Maximum Entropy Algorithm and its Implementation for the Neutral Beam Profile Measurement

  • Lee, Seung-Wook;Gyuseong Cho;Cho, Yong-Sub
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 추계학술발표회논문집(1)
    • /
    • pp.329-334
    • /
    • 1997
  • A tomography algorithm to maximize the entropy of image using Lagrangian multiplier technique and conjugate gradient method has been designed for the measurement of 2D spatial distribution of intense neutral beams of KSTAR NBI(Korea Superconducting Tokamak Advanced Research Neutral Beam Injector) which is now being designed. A possible detection system was assumed and a numerical simulation has been implemented to test the reconstruction quality of given beam profiles. This algorithm has the good applicability for sparse projection data and thus, can be used for the neutral beam tomography.

  • PDF

다엽형상의 포일을 사용한 공기 저널 베어링의 정특성에 관한 연구 (A study on hydrostatic characteristics of air-lubricated journal bearing using multi-leaf type foils)

  • 김태호;이용복;김창호;이남수;장건희
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2000년도 제32회 추계학술대회 정기총회
    • /
    • pp.177-185
    • /
    • 2000
  • The characteristics of multi-leaf feil bearing are investigated. The Foil bearing is preloaded and has several leaf foils modeled by curved beams. An analysis of the air foil bearing was performed, considering effects of foil deflection and compressible lubrication equation simultaneously. A parametric study shows that the number of foils significantly affect the static characteristics of air foil bearings and describes what the minimum film thickness means. The results include pressure profile, load capacity, dimensionless torque and minimum film thickness in the foil bearing.

  • PDF

Monte Carlo Algorithm-Based Dosimetric Comparison between Commissioning Beam Data across Two Elekta Linear Accelerators with AgilityTM MLC System

  • Geum Bong Yu;Chang Heon Choi;Jung-in Kim;Jin Dong Cho;Euntaek Yoon;Hyung Jin Choun;Jihye Choi;Soyeon Kim;Yongsik Kim;Do Hoon Oh;Hwajung Lee;Lee Yoo;Minsoo Chun
    • 한국의학물리학회지:의학물리
    • /
    • 제33권4호
    • /
    • pp.150-157
    • /
    • 2022
  • Purpose: Elekta synergy® was commissioned in the Seoul National University Veterinary Medical Teaching Hospital. Recently, Chung-Ang University Gwang Myeong Hospital commissioned Elekta Versa HDTM. The beam characteristics of both machines are similar because of the same AgilityTM MLC Model. We compared measured beam data calculated using the Elekta treatment planning system, Monaco®, for each institute. Methods: Beam of the commissioning Elekta linear accelerator were measured in two independent institutes. After installing the beam model based on the measured beam data into the Monaco®, Monte Carlo (MC) simulation data were generated, mimicking the beam data in a virtual water phantom. Measured beam data were compared with the calculated data, and their similarity was quantitatively evaluated by the gamma analysis. Results: We compared the percent depth dose (PDD) and off-axis profiles of 6 MV photon and 6 MeV electron beams with MC calculation. With a 3%/3 mm gamma criterion, the photon PDD and profiles showed 100% gamma passing rates except for one inplane profile at 10 cm depth from VMTH. Gamma analysis of the measured photon beam off-axis profiles between the two institutes showed 100% agreement. The electron beams also indicated 100% agreement in PDD distributions. However, the gamma passing rates of the off-axis profiles were 91%-100% with a 3%/3 mm gamma criterion. Conclusions: The beam and their comparison with MC calculation for each institute showed good performance. Although the measuring tools were orthogonal, no significant difference was found.

Seismic analysis of high-rise steel frame building considering irregularities in plan and elevation

  • Mohammadzadeh, Behzad;Kang, Junsuk
    • Steel and Composite Structures
    • /
    • 제39권1호
    • /
    • pp.65-80
    • /
    • 2021
  • Irregularities of a building in plan and elevation, which results in the change in stiffness on different floors highly affect the seismic performance and resistance of a structure. This study motivated to investigate the seismic responses of high-rise steel-frame buildings of twelve stories with various stiffness irregularities. The building has five spans of 3200 mm distance in both X- and Z-directions in the plan. The design package SAP2000 was adopted for the design of beams and columns and resulted in the profile IPE500 for the beams of all floors and box sections for columns. The column cross-section dimensions vary concerning the number of the story; one to three: 0.50×0.50×0.05m, four to seven: 0.45×0.45×0.05 m, and eight to twelve: 0.40×0.40×0.05 m. Real recorded ground accelerations obtained from the Vrancea earthquake in Romania together with dead and live loads corresponding to each story were considered for the applied load. The model was validated by comparing the results of the current method and literature considering a three-bay steel moment-resisting frame of eight-story height subject to seismic load. To investigate the seismic performance of the buildings, the time-history analysis was performed using ABAQUS. Deformed shapes corresponding to negative and positive peaks were provided followed by the story drifts and fragility curves which were used to examine the probability of collapse of the building. From the results, it was concluded that regular buildings provided a seismic performance much better than irregular buildings. Furthermore, it was observed that building with torsional irregularity was more vulnerable to seismic failure.

방사선 세기 조절 치료에서 선량을 규명하는 데 사용된 BlnS System의 특성 (The Properties of Beam Intensity Scanner (BInS) for Dose Verification in Intensity Modulated Radiation Therapy)

  • 박영우;박광열;박경란;권오현;이명희;이병용;지영훈;김근묵
    • 한국의학물리학회지:의학물리
    • /
    • 제15권1호
    • /
    • pp.1-8
    • /
    • 2004
  • 방사선 치료과정에서 가장 중요한 것은 환자에게 조사된 흡수선량을 검증하는 것이다. IMRT에 사용되는 방사선의 물리적 특성을 결정하고 환자에 조사된 선량분포를 검증할 수 있는 정밀한 선량 측정 장치가 필요하다. 본 연구에서 2차원 광자선의 선량검증을 위해 만들어진 BInS (Beam Intensity Scanner)에 관하여 논의한다. BInS에 있는 Scintillator는 광자선이나 전자선에 조사되면 형광을 발생하는 Gd$_2$O$_2$S:Tb를 주성분으로 한다. Scintillator에서 발생된 형광은 디지털 비디오카메라에 의해 수집되어 디지털 신호로 바뀌고 자체 제작한 소프트웨어에 의해 분석되며 상대적인 선량 분포가 3차원 그림으로 표시된다. BInS가 IMRT에서 사용가능한지를 알아보기 위하여 치료에 관련된 몇 가지 측정을 하였다. IMRT의 주요 작동방식 중의 하나인 SMLC (static multileaf collimator) 방식에서는, leaf들의 동작을 통제하여 만들어지는 여러 개의 정적 조사면적(static portal)을 통하여 IMB (intensity modulated beam)이 만들어진다. 따라서 여러 개의 정적 조사면적이 연달아 맞닿아 있는 경우, 연속된 두 조사면적의 경계면에서 penumbra와 산란된 광자들이 겹쳐지고 따라서 hot spot이 생기게 된다. 이와 같이 SMLC 방식에서 나타나는 inter-step hot spot들의 존재를 BInS를 이용하여 측정하여 가시화하였고 또한 그것들을 제거하는 실험적 방법도 제시하였다. IMRT에서 사용되는 다른 주요한 작동방식인 DMLC (dynamic multileaf collimator)는 광자선이나 전자선을 제어하는 leaf의 작동방식이 다르기 때문에 SMLC 방식과는 다른 특성을 보인다. 따라서 BInS를 이용하여 SMLC와 DMLC 방식에 의해 실제로 target에 투사된 선량을 측정 비교하였다. 비록 같은 선량을 target 부위에 투사하기로 계획했을지라도, 실제로는 산란된 광자와 전자들 때문에 DMLC 방식에 의한 선량이 SMLC 방식에 의한 선량보다 14.8%나 큰 것으로 측정되었다.

  • PDF

2파장 보정 Laser-Induced Incandescence 법을 이용한 매연 농도 측정 (Quantitative Measurement of Soot concentration by Two-Wavelength Correction of Laser-Induced Incandescence Signals)

  • 정종수
    • 한국자동차공학회논문집
    • /
    • 제5권3호
    • /
    • pp.54-65
    • /
    • 1997
  • To quantify the LII signals from soot particle of flames in diesel engine cylinder, a new method has been proposed for correcting LII signal attenuated by soot particles between the measuring point and the detector. It has been verified by an experiment on a laminar jet ethylene-air diffusion flame. Being proportional to the attenuation, the ratio of LII signal at two different detection wavelengths can be used to correct the measured LIIsignal and obtain the unattenuated LII signal, from which the soot volume fraction in the flame can be estimated. Both the 1064-nm and frequency-doubled 532-nm beams from the Nd : YAG laser are used. Single-shot, one-dimensional(1-D) line images are recorded on the intensified CCD camera, with the rectangular-profile laser beam using 1-mm-diameter pinhole. Two broadband optical interference filters having the center wavelengths of 647 nm and 400 nm respectively and a bandwidth of 10 nm are used. This two-wavelength correction has been applied to the ethylene-air coannular laminar diffusion flame, previously studied on soot formation by the laser extinction method in this laboratory. The results by the LII measurement technique and the conventional laser extinction method at the height of 40 nm above the jet exit agreed well with each other except around outside of the peaks of soot concentration, where the soot concentration was relatively high and resulting attenuation of the LII signal was large. The radial profile shape of soot concentration was not changed a lot, but the absolute value of the soot volume fraction around outside edge changed from 4ppm to 6.5 ppm at r=2.8mm after correction. This means that the attenuation of LII signal was approximately 40% at this point, which is higher than the average attenuation rate of this flame, 10~15%.

  • PDF

수종의 측정기에 의한 전자선의 선량 측정의 비교 (Comparison of Electron Beam Dosimetries by Means of Several Kinds of Dosimeters)

  • 강위생
    • Radiation Oncology Journal
    • /
    • 제7권1호
    • /
    • pp.93-100
    • /
    • 1989
  • 전자선의 선량을 측정하기 위하여 수종의 측정기와 팬톰의 조합에 대해서 실험 및 결과를 분석하였다. 전자선의 선축상 선량분포가 조사면의 크기에 좌우되는지를 알기 위하여 실리콘 PN 접합형 다이오드를 사용하였다. 50 및 80, $90\%$ 선량점의 깊이가 작은 조사면에 대해서는 조사면의 크기에 따라 증가하지만, 큰 조사면에 대해서는 거의 일정했다. 그러나 그 깊이가 일정한 경우 최소 조사면의 크기가 뚜렷하지는 않으나 전자선의 에너지가 증가함에 따라 증가하였다. $6\~18MeV$의 전자선에 대해 조사면의 크기가 $10\times10cm^2$ 이상인 경우 그 깊이 가 어느 에너지에 대해서도 조사면의 크기에 무관함이 측정치에서 관찰되었다. 그래서 수종의 측정기와 팬톰의 결합에 따른 전자선의 선축상 선량분포의 차이점을 관찰하고자 하는 실험에서 조사면의 크기로 $10\times10cm^2$을 선택하였다. 원주형 전리함과 평판형 전리함, 필름은 폴리스티렌 팬톰과 함에, 실리콘다이오드는 물팬톤과 함께 선량측정에 이용되었다. 원주형 전리함은 표면선량이나 6MeV처럼 낮은 에너지의 선량증가 영역에서 선량을 측정할 수 없었다. 몇 가지를 제외하고는 측정된 변수들은 서로 다른 측정기 및 팬톰의 결합에 관계없이 거의 동일하였다. 어떤 에너지에서는 서로 다른 측정기에 의한 표면선량이 $4\%$ 정도 차이가 났으며, 에너지가 증가함에 따라 그 대소가 반전되기도 하였다. 18MeV의 경우 필름에 의한 80 및 $90\%$ 선량점의 깊이가 다른 측정기에 의한 것보다 꽤 얕았다. 평판형 전리함과 실리콘 다이오드는 전자선의 선량분포측정에 사용될 수 있겠으나 평판형 전리함은 큰 조사면에서만 사용하는 것이 바람직할 것이 다. 표면선량 측정이나 저 에너지 전자선의 선량증가 부분에서 선량측정에는 원주형 전리함을 사용하지 않는 것이 바람직할 것이다. 18 MeV와 같이 높은 에너지의 전자선의 선량분포 측정에 필름이 사용되어도 좋을지 의심스럽다.

  • PDF

세기조절방사선치료(Intensity Modulated Radiation Therapy; IMRT)의 정도보증(Quality Assurance) (Quality Assurance for Intensity Modulated Radiation Therapy)

  • 조병철;박석원;오도훈;배훈식
    • Radiation Oncology Journal
    • /
    • 제19권3호
    • /
    • pp.275-286
    • /
    • 2001
  • 목적 : 세기조절방사선치료의 임상적용을 위한 정도보증 절차를 확립하고, 실제 치료환자 1례에 대한 적용 과정을 보고하고자 한다. 대상 및 방법 : 본원에서는 세기조절방사선치료를 시행하기 위해 역방향 치료계획(inverse planning) 시스템으로 $P^3IMRT$ (ADAC, 미국)와 다엽콜리메이터(Multileaf collimator, MLC)가 부착된 방사선치료용 선형가속기 Primus (Siemens, 미국)를 사용하였다. 먼저 다엽콜리메이터에 대한 위치의 정확성, 재현성, leaf transmission factor를 측정하였다. 또한 소조사면에 대한 치료계획시스템의 commissioning을 실시하였다. 이를 이용하여 C자 형태의 가상 PTV (Planning Target Volume)에 대해 9개의 빔을 사용하여 세기변조 조사빔을 설계하여, 이를 팬톰 내에서 절대선량 및 상대선량을 측정하여 비교, 분석하였다. 실제 6개의 세기변조 조사빔을 사용하여 치료를 시행한 전립선암 환자를 대상으로, 팬톰내에서 재 계산된 선량계산 결과를 0.015 cc 미소전리함, 다이오드선량계(Scanditronix, 스웨덴), 필름 선량계, 그리고 선형배열다중검출기(array detector) 등을 사용하여 절대선량 및 상대선량을 평가하였다. 결과 : MLC 위치 정확도는 1 mm 이내이었으며, 재현성은 0.5 mm 내외로 평가되었고, leaf transmission 인자는 10MV 광자선에 대해서 interleaf leakage의 경우, $1.9\%$, midleaf leakage의 경우, $0.9\%$로 측정되었다. 필름, 다이오드선량계, 미소전리함, 물팬톰용 전리함(0.125 cc) 등의 반음영을 측정해 본 결과, 물팬톰용 전리함으로 측정된 반음영 영역$(80\~20\%)$은 필름에 비해 2 mm 가량 크며, 최소 beamlet 크기가 5 mm 임을 감안할 때 부적합한 것으로 판명되었다. RTP commissioning 후 계산 선량은 $1\times1\;cm^2$ 크기 소조사면에서의 측정치와 $2\%$ 범위 내에서 일치하였다. C자 형태의 PTV에 대한 9개의 세기변조된 조사빔에 대한 2회에 걸친 치료중심점에서의 절대선량 측정결과 개별 조사빔에 대하여는 $10\%$ 이상 차이를 보였으나 총 선량은 $2\%$ 이내에서 일치하였다. 필름을 이용한 선량분포도도 계산치와 비교적 잘 일치하였다. 실제 치료환자의 팬톰 내에서의 절대선량 측정 결과 총 선량은 $1.5\%$ 차이를 보였다. 각 조사빔에 대해 중심 leaf의 측방선량분포도를 필름 및 선형배열다중검출기를 사용하여 측정하였으며, 조사면 밖에서 계산선량이 $2\%$ 내외로 작게 나타났으나, 특정 위치를 제외하고는 $3\%$ 이내로 잘 일치함을 확인하였다. 결론 : 세기조절방사선치료를 위해서는 다엽콜리메이터의 위치에 대한 보다 정밀한 정도관리 절차가 개발되어야 될 것으로 판단되며, 조사빔내 세기패턴을 효율적으로 확인할 수 있는 정도보증 절차가 필요할 것으로 사료된다. 본원에서는 팬톰 내에서의 치료중심점과 같이 특정 지점에서의 절대선량 확인 및 필름 혹은 선형배열다중검출기를 사용한 세기분포 패턴의 확인 과정을 통하여, 이를 적절히 병행하여 사용함으로써 세기조절방사선치료에 적합한 정도관리를 시행할 수 있었다.

  • PDF