• Title/Summary/Keyword: probe image

Search Result 211, Processing Time 0.024 seconds

The Development of Beamline Hutch Structures at PAL-XFEL (PAL-XFEL 빔라인 허치 구조물 개발)

  • Kim, Seungnam;Kim, Myeongjin;Kim, Seonghan;Kim, Yeongchan;Shin, Hocheol;Kim, Jihwa;Kim, Kyeongsuk;Kim, Kwangwoo;Eom, Intae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.5
    • /
    • pp.567-577
    • /
    • 2016
  • The hutches which are installed in the beamline are largely classified into two, i.e XPP (X-ray pump probe) and CXI (Coherent X-ray image). Laser room is installed on the hutch and provides laser to XPP and CXI simultaneously. And two hutches have heavy crane to install some optics equipments. Safety and reliability of hutch structures should be taken into account for the precise operating of the laser facilities, so vibration analysis is essential to do this. The main purpose of vibration analysis is to install hutch structures with large stiffness. We have changed materials specification several times to install hutch structures having strong stiffness. Now hutch structures were installed and checked vibration status at laser room and XPP hutch. The results of laser table and robot arm satisfy vibration criteria. This paper explains about the design and vibration analysis of hutch structures.

Analysis of Accumulation/Erosion in River Using Satellite Image (인공위성영상을 이용한 하천의 퇴적/침식 분석)

  • Yang In-Tae;Kim Dong-Moon;Chun Ki-Sun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.24 no.1
    • /
    • pp.37-45
    • /
    • 2006
  • Damage of rivers construction is serious to natural disaster by concentration rainfall in summer. Specially, increase of soil erosion breeds flood calamity of river bed accumulation and pondage decline etc., and erosion increase in upper stream shows in rivers flood of earth and sand, farm land and form of urban district burying. Flood damage investigation through on-the-spot probe until present need effective and scientific modelling techniques because is not efficient. This research wished to examine practical use of monitoring data of high resolution satellite image through satellite image analysis of various space resolution. Research analyzed abstraction possibility of soil disaster information using high resolution satellite image. Also, studied soil disaster damage present condition interpretation practical use possibility through various resolution satellite image analysis, and studied practical use of KOMPSAT image for interpretation of river topography change analysis.

Changes and Meanings of the Images of Female Model on the Cover of Men's Fashion Magazines (남성 패션잡지 표지에 나타난 여성모델 이미지 변화와 의미 분석)

  • Kwon, Jeanne;Yim, Eun-Hyuk
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.17 no.2
    • /
    • pp.79-92
    • /
    • 2015
  • Covers of fashion magazines are part of the media that reflects the zeitgeist. Thus an analysis of the covers is a tool to probe the social and cultural changes of a period. This study attempts to shed light on the changes of the image of women on the cover of men's fashion magazines; this study intends to investigate the changes of status and role of women, from the past up to the present, through analyzing the meaning of the image of female models. For this purpose, this study conducts both literature and corroborative research. The period for the analysis is limited to post-1960s when female models began to appear alone on the cover of men's fashion magazine. The three decades from the 1960s through today have been analyzed according to its characteristics. The result is as follows: female models in the 1960s were shown as subjugated and ancillary to men as a commodity for the affluent materialistic civilization after World War II. In the 1970s, thanks to feminism movement, the image of resistance dominated. As a result of women's right movement, the 1980s came to witness the female image of subjective characteristics. Finally, starting in the 1990s, a mixture of subjugated, resistant, and subjective image of female models has appeared. In the contemporary culture, where the communication through images is being increased, the image of the female models in fashion magazines could work as a criterion to measure the social change.

  • PDF

Image-guided Surgery System Using the Stereo Matching Method (스테레오 매칭 기법을 이용한 영상유도시술 시스템)

  • 강현수;이호진;문찬홍;문원진;김형진;최근호;함영국;이수열;변홍식
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.339-346
    • /
    • 2003
  • MRI provides anatomical structure information with superb spatial resolution that can be utilized in clinical surgeries. Advanced image processing techniques in conjunction with the MRI-guided surgery is expected to be of great importance in brain surgeries in the near future. In this paper, we introduce an image-guided surgery technique using the stereo matching method. To perform image-guided biopsy operations, we made MRI markers, camera markers and a detection probe marker. To evaluate the accuracy of the image-guided system. we made a silicone phantom. Using the phantom and markers, we have performed MRI-guided experiments with a 1.5 Tesla MRI system. It has been verified from phantom experiments that our system has a positioning error less than 1.5%. Compared with other image guided surgery system, our system shows better positioning accuracy.

Probe Vehicle Data Collecting Intervals for Completeness of Link-based Space Mean Speed Estimation (링크 공간평균속도 신뢰성 확보를 위한 프로브 차량 데이터 적정 수집주기 산정 연구)

  • Oh, Chang-hwan;Won, Minsu;Song, Tai-jin
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.19 no.5
    • /
    • pp.70-81
    • /
    • 2020
  • Point-by-point data, which is abundantly collected by vehicles with embedded GPS (Global Positioning System), generate useful information. These data facilitate decisions by transportation jurisdictions, and private vendors can monitor and investigate micro-scale driver behavior, traffic flow, and roadway movements. The information is applied to develop app-based route guidance and business models. Of these, speed data play a vital role in developing key parameters and applying agent-based information and services. Nevertheless, link speed values require different levels of physical storage and fidelity, depending on both collecting and reporting intervals. Given these circumstances, this study aimed to establish an appropriate collection interval to efficiently utilize Space Mean Speed information by vehicles with embedded GPS. We conducted a comparison of Probe-vehicle data and Image-based vehicle data to understand PE(Percentage Error). According to the study results, the PE of the Probe-vehicle data showed a 95% confidence level within an 8-second interval, which was chosen as the appropriate collection interval for Probe-vehicle data. It is our hope that the developed guidelines facilitate C-ITS, and autonomous driving service providers will use more reliable Space Mean Speed data to develop better related C-ITS and autonomous driving services.

Post-tuning of Sample Position in Common-path Swept-source Optical Coherence Tomography

  • Park, Jae-Seok;Jeong, Myung-Yung;Kim, Chang-Seok
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.380-385
    • /
    • 2011
  • Common-path interferometers are widely used for endoscopic optical coherence tomography (OCT) because an arbitrary arm length can be chosen for the endoscopic imaging probe. However, the scheme suffers from the limited range of the sample position distance from the end of the imaging probe because the position between the reference reflector and the sample is limited by the optical path-length difference (OPD) to induce an interference signal. In this study, we developed a novel method for compensating the arbitrary sample position in common-path swept-source OCT by adding an extra Mach-Zehnder interferometer in the post-path of the interfered optical signal. Theoretical analysis and an experimental demonstration of imaging depth tuning for the flexible sample position of an endoscopic OCT image are discussed. After post-tuning of sample position distance, the positioning limitation between the reference reflector and the sample can be solved for various sample positions over a range of 26 mm for the cross-sectional images of a fish eye sample.

Improving data reliability on oligonucleotide microarray

  • Yoon, Yeo-In;Lee, Young-Hak;Park, Jin-Hyun
    • Proceedings of the Korean Society for Bioinformatics Conference
    • /
    • 2004.11a
    • /
    • pp.107-116
    • /
    • 2004
  • The advent of microarray technologies gives an opportunity to moni tor the expression of ten thousands of genes, simultaneously. Such microarray data can be deteriorated by experimental errors and image artifacts, which generate non-negligible outliers that are estimated by 15% of typical microarray data. Thus, it is an important issue to detect and correct the se faulty probes prior to high-level data analysis such as classification or clustering. In this paper, we propose a systematic procedure for the detection of faulty probes and its proper correction in Genechip array based on multivariate statistical approaches. Principal component analysis (PCA), one of the most widely used multivariate statistical approaches, has been applied to construct a statistical correlation model with 20 pairs of probes for each gene. And, the faulty probes are identified by inspecting the squared prediction error (SPE) of each probe from the PCA model. Then, the outlying probes are reconstructed by the iterative optimization approach minimizing SPE. We used the public data presented from the gene chip project of human fibroblast cell. Through the application study, the proposed approach showed good performance for probe correction without removing faulty probes, which may be desirable in the viewpoint of the maximum use of data information.

  • PDF

Microstructure Evaluation of Nano-thick Au-inserted Nickel Silicides (나노급 Au층 삽입 니켈실리사이드의 미세구조 변화)

  • Yoon, Ki-Jeong;Song, Oh-Sung
    • Korean Journal of Materials Research
    • /
    • v.18 no.1
    • /
    • pp.5-11
    • /
    • 2008
  • Thermally evaporated 10 nm-Ni/1 nm-Au/(30 nm-poly)Si structures were fabricated in order to investigate the thermal stability of Au-inserted nickel silicide. The silicide samples underwent rapid thermal annealing at $300{\sim}1100^{\circ}C$ for 40 seconds. The sheet resistance was measured using a four-point probe. A scanning electron microscope and a transmission electron microscope were used to determine the cross-sectional structure and surface image. High-resolution X-ray diffraction and a scanning probe microscope were employed for the phase and surface roughness. According to sheet resistance and XRD analyses, nickel silicide with Au had no effect on widening the NiSi stabilization temperature region. Au-inserted nickel silicide on a single crystal silicon substrate showed nano-dots due to the preferred growth and a self-arranged agglomerate nano phase due to agglomeration. It was possible to tune the characteristic size of the agglomerate phase with silicidation temperatures. The nano-thick Au-insertion was shown to lead to self-arranged microstructures of nickel silicide.

Use of Mammary Lymphoscintigraphy and Intraoperative Radioguided Gamma Probe in Sentinel Lymph Node Biopsy of Breast Cancer (유방암 환자의 전초림프절 생검에서 유방림프신티그라피와 수술 중 감마프로우브의 유용성)

  • Kim, Soon;Zeon, Seok-Kil;Kim, Yu-Sa
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.6
    • /
    • pp.478-486
    • /
    • 2000
  • Purpose: The sentinel lymph node is defined as the first draining node from a primary tumor and reflects the histologic feature of the remainder of the lymphatic basin status. The aim of this study was to evaluate the usefulness of lymphoscintigraphy and intraoperative radioguided gamma probe for identification and removal of sentinel lymph node in breast cancer. Materials and Methods: Lymphoscintigraphy was performed preoperatively in 15 patients with biopsy proven primary breast cancer. Tc-99m antimony sulfide colloid was injected intradermally at four points around the tumor. Imaging acquisition included dynamic imaging, followed by early and late static images at 2 hours. The sentinel lymph node criteria on lymphoscintigraphy is the first node of the highest uptake in early and late static images. We tagged the node emitting the highest activity both in vivo and ex vivo. Histologic study for sentinel and axillary lymph node investigation was done by Hematoxylin-Eosin staining. Results: On lymphoscintigraphy, three of 15 patients had clear lymphatic vessels in dynamic images, and 11 of 15 patients showed sentinel lymph node in early static image and three in late static 2 hours image. Mean detection time of sentinel lymph node on lymphoscintigraphy was $33.5{\pm}48.4$ minutes. The sentinel lymph node localization and removal by lymphoscintigraphy and intraoperative gamma probe were successful in 14 of 15 patients (detection rate: 93.3%). On lymphoscintigraphy, 14 of 15 patients showed $2.47{\pm}2.00$ sentinel lymph nodes. On intraoperative gamma probe, $2.36{\pm}1.96$ sentinel lymph nodes were detected. In 7 patients with positive results of sentinel lymph node metastasis, 5 patients showed positive results of axillary lymph node (sensitivity: 72%) but two did not. In 7 patients with negative results of sentinel lymph node metastasis, all axillary nodes were free of disease (specificity: 100%). Conclusion: Sentinel lymph node biopsy with lymphoscintigraphy and intraoperative gamma probe is a reliable method to predict axillary lymph node metastasis in breast cancer, and unnecessary axillary lymph node dissection can be avoided.

  • PDF

Development and evaluation of MR compatible patch antenna for hyperthermia (온열치료를 위한 MR호환 평판가열안테나 개발 및 성능평가)

  • Kim, D.H.;Chun, S.I.;Jang, M.Y.;Yoon, M.S.;Kim, Y.B.;Jung, B.D.;Nam, S.H.;Mun, C.W.
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.2
    • /
    • pp.17-21
    • /
    • 2009
  • The thermal treatment have been combined with MRI which is able to acquire both an anatomical image with high-contrast and a thermal image, and have recently used for removing the tumor effectively. This study is to make a patch antenna which is designed to operate at 2.45GHz that has compatibility with MRI. The characteristic and specific absorption rate(SAR) were confirmed using computer simulation and confirmed a possibility of hyperthermia by performing experiment.

  • PDF