• 제목/요약/키워드: primary phase

Search Result 1,065, Processing Time 0.023 seconds

Experimental and Numerical Study on Characteristics of Air-assisted Spray and Spray Flames (2유체 분무의 연소특성에 관한 실험 및 수치 해석적 연구)

  • Kim, Dong-Il;Oh, Sang-Huen
    • Journal of the Korean Society of Combustion
    • /
    • v.3 no.2
    • /
    • pp.51-63
    • /
    • 1998
  • Air-assisted atomizer flames are investigated numerically to study spray structures in nonburning and burning conditions based on experimental data. A PDA is used to measure droplet size, velocity, and number density for both nonburning and burning spray. Computations utilize time-averaged gas-phase equations and $k-{\varepsilon}$ turbulence model for simplicity. The major features of the liquid-phase model are that a SSF approach is used to represent the effect of gas-phase turbulence on droplet trajectories and vaporization, an infinite-diffusion model is employed to represent the transient liquid-phase process. Computation and experiment results show that the droplet acceleration and evaporation proceed quickly in near the atomizer, characterizing high number densities and a strong convective effect. The primary combustion zone, however, is dorminated by the gas phase reaction and exhibits a sheath combustion.

  • PDF

Improved Phase-shift Pulse-width Modulation Full-bridge Converter using a Blocking Capacitor (블로킹커패시터를 이용한 향상된 위상천이 펄스폭변조 풀브리지 컨버터)

  • Jeong, Gang-Youl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.8
    • /
    • pp.20-29
    • /
    • 2011
  • This paper presents an improved phase-shift pulse-width modulation (PWM) full-bridge converter using a blocking capacitor. As the proposed converter reduces the circulation energy by inserting only one series blocking capacitor at the primary side of the conventional phase-shift PWM full-bridge converter structure, it improves the operation characteristics of the conventional converter. In this paper, first, the operation of conventional phase-shift PWM full-bridge converter is roughly reviewed, and then the operational principle of the proposed converter is classified and explained by each mode. After that, a prototype design example based on the operational principle is shown. Then, the improved operation characteristics of the proposed converter are actually verified through the experimental results.

Current Limiting Characteristics of a Flux-Lock Type SFCL for a Single-Line-to-Ground Fault

  • Oh, Geum-Kon;Jun, Hyung-Seok;Lee, Na-Young;Choi, Hyo-Sang;Nam, Gueng-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.9
    • /
    • pp.70-77
    • /
    • 2006
  • We have fabricated an integrated three-phase flux-lock type SFCL, which consists of an YBCO($YB_a2Cu_3O_7$) thin film and a flux-lock reactor wound around an iron core of each phase. In order to apply the SFCL in a real power system, fault analyses for the three-phase system are essential. The short-circuit currents were effectively limited by adjusting the numbers of winding of each secondary coil and their winding directions. The flux flow generated in the iron core cancelled out under the normal operation due to the parallel connection between primary and secondary windings. However, the flux-lock type SFCL with same iron core was operated just after the fault due to the flux generating in the iron core. To analyze the current limiting characteristics, the additive polarity winding was compared with the subtractive one in the flux lock reactor. Whenever a single line-to-ground fault occurred in any phase, the peak value of the line current of the fault phase in the additive polarity winding increased up to about 12.87 times during the first-half cycle. On the other hand, the peak value in the subtractive polarity winding increased up to about 34.07 times under the same conditions. This is because the current flow between the primary and the secondary windings changed to additive or subtractive status according to the winding direction. We confirmed that the current limiting behavior in the additive polarity winding was more effective for a single-line-to-ground fault

Formation and Microstructure Characteristics of $\beta-Al_5FeSi$ Intermetallic Compound in the Al-Si-Cu Alloys with the Variation of Fe Content (Al-Si-Cu합금에서 Fe 함량에 따른 $\beta-Al_5FeSi$ 금속간화합물의 형성 및 응고미세조직 특성)

  • Kim, Bong-Hwan;Lee, Sang-Mok
    • Journal of Korea Foundry Society
    • /
    • v.29 no.5
    • /
    • pp.225-232
    • /
    • 2009
  • For comprehensive understanding of the formation behavior of $\beta-Al_5FeSi$ phase in Al-Si-Cu alloys with the existence of Fe element, microstructure characterizations were performed using combined analysis of OM, SEM-EDS, XRD. Especially, experimental and predictive works on solidification events of $\beta-Al_5FeSi$ phase as well as other phases formed together with $\beta-Al_5FeSi$ have been carried out by using DSC analysis and Java-based Materials Properties software (J. Mat. Pro.). Primary and eutectic $\beta-Al_5FeSi$ phases were able to distinguish from each other on microstructures by their morphological features. Primary $\beta-Al_5FeSi$ phase was seen to have rough surface perpendicular to growth direction, indicating free attachment of solute atoms in liquid state. On the other hand, the eutectic $\beta-Al_5FeSi$ phase was formed with plain and straight surface during eutectic reaction together with $\alpha$-Al phase. The eutectic reaction of $\beta-Al_5FeSi$ and $\alpha$-Al phases was seen to be able to separate into each formation depending on cooling rate.

The Positional Effect of Solute Functional Group among Positional Isomers of Phenylpropanol in Hydroxyl Group-Solvent Specific Interactions in Methanol/Water Mixed Solvents Monitored by HPLC

  • Cheong, Won-Jo;Ko, Joung-Ho;Kang, Gyoung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.8
    • /
    • pp.1246-1250
    • /
    • 2005
  • We have evaluated the hydroxyl group-solvent specific interactions by using a Lichrosorb RP18 stationary phase and by measuring the retention data of carefully selected solutes in 50/50, 60/40, 70/30, 80/20, and 90/10(v/v%) methanol/water eluents at 25, 30, 35, 40, 45, and 50 ${^{\circ}C}$. The selected solutes are 3 positional isomers of phenylpropanol, that is, 1-phenyl-1-propanol, 1-phenyl-2-propanol, and 3-phenyl-1-propanol. There exist clear discrepancies in ${\Delta}H^o$ (solute transfer enthalpy from the mobile to the stationary phase) and $T{\Delta}S^o$ (solute transfer entropy) among positional isomers. The difference in ${\Delta}H^o$ and $T{\Delta}S^o$ between secondary alcohols (1-phenyl-1-propanol and 1-phenyl-2-propanol)is negligible compared to the difference between the primary alcohol (1-phenyl-3-propanol) and secondary alcohols. The $T{\Delta}S^o$ values of 3-phenyl-1-propanol are close to those of butylbenzene while the $T{\Delta}S^o$ values of secondary alcohols are close to those of propylbenzene. The difference in ${\Delta}{\Delta}H^o$ (specific solute-mobile phase interaction enthalpy) between the primary alcohol and the secondary alcohol decreases with increase of methanol content in the mobile phase. A unique observation is an extremum for 1-phenyl-3-propanol in the plot of $T{\Delta}{\Delta}S^o$ vs. methanol volume %. The positive sign of $T{\Delta}{\Delta}S^o$ of 3-phenyl-1-propanol implies that the entropy of 3-phenyl-1-propanol is greater than that of the hypothetical alkylbenzene (the same size and shape as phenylpropanol) in the mobile phase.

Analysis of Fault Current Limiting Characteristics According to Variation of Inductances in Separated Three-phase Flux-lock Type SFCL (분리된 삼상자속구속형 전류제한기의 인덕턴스 변화에 따른 전류제한 특성 분석)

  • Doo, Seung-Gyu;Du, Ho-Ik;Kim, Min-Ju;Park, Chung-Ryul;Kim, Yong-Jin;Lee, Dong-Hyeok;Han, Byoung-Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.6
    • /
    • pp.522-525
    • /
    • 2009
  • We investigated the fault current characteristics of the separates three-phase flux-lock type superconducting fault current limiter(SFCL) according to the variation of inductances. The single-phase flux-lock type SFCL consists of two coils. The primary coil is wound in parallel to the secondary coil on an iron core. And superconductor is series connected on secondary coil. Superconductor is using the YBCO coated conductor. The separated three-phase flux-lock type SFCL consists of single-phase flux-phase type SFCL in each phase. To analyze the current limiting characteristics of a three-phase flux-lock type SFCL, the short circuit experiments were carried out fault such as the triple line-to-ground fault. The experimental result shows that fault current limiting characteristics of additive polarity winding was better than subtractive polarity winding and when the inductances of coil 2 was lower, resistances of YBCO CC was more generated.

Image Authentication Using Only Partial Phase Information from a Double-Random-Phase-Encrypted Image in the Fresnel Domain

  • Zheng, Jiecai;Li, Xueqing
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.3
    • /
    • pp.241-247
    • /
    • 2015
  • The double-random phase encryption (DRPE) algorithm is a robust technique for image encryption, due to its high speed and encoding a primary image to stationary white noise. Recently it was reported that DRPE in the Fresnel domain can achieve a better avalanche effect than that in Fourier domain, which means DRPE in the Fresnel domain is much safer, to some extent. Consequently, a method based on DRPE in the Fresnel domain would be a good choice. In this paper we present an image-authentication method which uses only partial phase information from a double-random-phase-encrypted image in the Fresnel domain. In this method, only part of the phase information of an image encrypted with DRPE in the Fresnel domain needs to be kept, while other information like amplitude values can be eliminated. Then, with the correct phase keys (we do not consider wavelength and distance as keys here) and a nonlinear correlation algorithm, the encrypted image can be authenticated. Experimental results demonstrate that the encrypted images can be successfully authenticated with this partial phase plus nonlinear correlation technique.

Analysis on Fault Current Limiting Operation of Three-Phase Transformer Type SFCL Using Double Quench (이중퀜치를 이용한 삼상변압기형 한류기의 고장전류제한 동작 분석)

  • Han, Tae-Hee;Ko, Seok-Cheol;Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.2
    • /
    • pp.184-189
    • /
    • 2022
  • In this paper, the fault current limiting operations of three-phase transformer type superconducting fault current limiter (SFCL) using double quench, which consisted of E-I iron core with three legs wound by primary and secondary windings and two superconducting modules (SCMs), were analyzed according to three-phase ground fault types. To verify the effective operation of the three-phase transformer type SFCL using double quench, the test circuit for three-phase ground faults was constructed, and the fault current tests were carried out. Through analysis on the fault current test results, the different fault current limiting characteristics of three-phase transformer type SFCL using double quench from three-phase transformer type SFCL using three SCMs were discussed.

A Study on Detection Algorithm of Open Phase Fault in Grid-Connected Transformer for PV System (태양광전원 연계용변압기의 결상사고 검출 알고리즘에 관한 연구)

  • Kang, Kab-Seok;Tae, Dong-Hyun;Lee, Hu-Dong;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.22-33
    • /
    • 2021
  • In the case of open phase faults caused by the disconnection of distribution feeders interconnected to a PV system, many problems can occur depending on the core type and wiring method of the grid-connected transformers. Moreover, open phase faults are difficult to detect because the open phase voltage of the existing protection relay (Open Phase Relay (47)) can be maintained, even though a disconnection fault occurred, depending on the wiring method and the iron core type of the grid-connected transformer for a PV system. Therefore, this paper proposes a novel algorithm to detect open phase faults by comparing the currents and phases between the primary and secondary sides of a grid-connected transformer. In addition, this paper presents the modeling of a distribution system and protection devices for detecting open phase faults using PSCAD/EMTDC S/W, and implements a test protection device for detecting open phase faults based on the above-mentioned modeling. The simulation and test results confirmed that the proposed algorithm is useful for detecting open phase faults according to the wiring method and iron core type of grid-connected transformer for a PV system because operation slope and unbalance rate of the primary current exceed the setting value (30[%]) of the protection device.

GMT Project Update

  • Park, Byeong-Gon;Hwang, Narae;Kim, Young-Soo;Yuk, In-Soo;Lee, Jae-Joon;Yoon, Yang-Noh
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.81.1-81.1
    • /
    • 2013
  • The GMT project is moving ahead smoothly and is approaching the construction phase expected to begin around mid 2014. In this contribution, we will introduce the status of activities being made for the preparation of construction phase, including the Preliminary Design Review of sub-systems, the casting of primary mirror segments, and the GMT retreat.

  • PDF