• Title/Summary/Keyword: primary fluid

Search Result 479, Processing Time 0.026 seconds

A Study on BEM-Based Numerical Simulation Technique for Underwater Explosions (수중 폭발 시뮬레이션을 위한 경계 요소법 기반의 수치 해석 기법 연구)

  • Choung, Joonmo;Lee, Jae-bin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.57 no.5
    • /
    • pp.271-277
    • /
    • 2020
  • Recoverability and vulnerability of navy ships under underwater explosion are critical verification factors in the acquisition phase of navy ships. This paper aims to establish numerical analysis techniques for the underwater explosion of navy ships. Doubly Asymptotic Approach (DAA) Equation of Motion (EOM) of primary shock wave and secondary bubble pulse proposed by Geers-Hunter was introduced. Assuming a non-compressive fluid, reference solution of the DAA EOM of Geers-Hunter using Runge-Kutta method was derived for the secondary bubble pulse phase with an assumed charge conditions. Convergence analyses to determine fluid element size were performed, suggesting that the minimum fluid element size for underwater explosion analysis was 0.1 m. The spherical and cylindrical fluid domains were found to be appropriate for the underwater explosion analyses from the fluid domain shape study. Because the element size of 0.1 m was too small to be applied to the actual navy ships, a very slender beam with the square solid section was selected for the study of fluid domain existence effect. The two underwater explosion models with/without fluid domain provided very similar results in terms of the displacement and stress processes.

Utility of VEGF and sVEGFR-1 in Bronchoalveolar Lavage Fluid for Differential Diagnosis of Primary Lung Cancer

  • Cao, Chao;Sun, Shi-Fang;Lv, Dan;Chen, Zhong-Bo;Ding, Qun-Li;Deng, Zai-Chun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.4
    • /
    • pp.2443-2446
    • /
    • 2013
  • Published data have shown that the levels of vascular endothelial growth factor (VEGF) and soluble VEGF receptor-1 (sVEGFR-1) in plasma and pleural effusion might be usefulness for lung cancer diagnosis. Here, we performed a prospective study to investigate the utility of VEGF and sVEGFR-1 in bronchoalveolar lavage fluid (BALF) for differential diagnosis of primary lung cancer. A total of 56 patients with solitary pulmonary massed by chest radiograph or CT screening were enrolled in this study. BALF and plasma samples were obtained from all patients and analyzed for VEGF and sVEGFR-1 using a commercially available sandwich ELISA kit. The results showed that the levels of VEGF in BALF were significantly higher in patients with a malignant pulmonary mass compared with patients with a benign mass (P < 0.001). However, no significant difference of sVEGFR-1 in BALF was found between malignant and non-malignant groups (P = 0.43). With a cut-off value of 214 pg/ml, VEGF showed a sensitivity and specificity of 81.8% and 84.2%, respectively, in predicting the malignant nature of a solitary pulmonary mass. Our study suggests that VEGF is significantly increased in BALF among patients with lung cancer than in benign diseases. Measurement of VEGF in BALF might be helpful for differential diagnosis of primary lung cancer.

Development and Application of a Computer Program for the Analysis of Heat Transfer and Fluid Flow of Water Body: Lake and Primary Clarifier (水體 熱流動 數値解析 프로그램 개발 및 응용 : 湖沼, 일차침전조)

  • 박병수;김경미
    • Water for future
    • /
    • v.29 no.6
    • /
    • pp.141-154
    • /
    • 1996
  • A computer program is developed in order to investigate the fluid flow and heat ransfer of a water body in a 2-D vertical rectangular coordinate. The specific purpose of this study is to obtain a physical insight of several fluid flow problems which occur in a lake and the water and wastewater treatment facility like a primary clarifier. The performance of computer program developed is successfully evaluated by the comparison of other two experimental and computational data in open literature : the first comparison is made against the numerical data associated with the cooling water discharge and the other is numerical and experimental works for the primary clarifier of Sarina City at Ontario. Further, the computer program is applied to investigate the feature of lake flow, say lake turnover, and 2-D vertical channel flow in terms of temperature, wind velocity and flow rate, etc. The computational results appear to be physically acceptable and consistent. The computer program developed in this study shows the possibility of the viable tool to figure out the flow characteristics of water reservoir.

  • PDF

Performance Analysis of Ejector-Pump Thermal Energy Conversion System Using Various Working Fluids (이젝터-펌프 온도차발전시스템의 작동유체별 성능분석)

  • Yoon, Jung-In;Seol, Sung-Hoon;Son, Chang-Hyo;Choi, Kwang-Hwan;Kim, Young-Bok;Lee, Ho-Saeng;Kim, Hyeon-Ju;Moon, Jung-Hyun
    • Journal of Power System Engineering
    • /
    • v.20 no.6
    • /
    • pp.87-92
    • /
    • 2016
  • This research dealt with performance characteristics of OTEC system applying an ejector and additional pump. Each system using five kinds of working fluids was analyzed, and primary parameters with respect to entrainment ratio were examined: Turbine gross power, evaporation capacity, pump work, efficiency and volume flow ratio. The primary results were as following. The efficiency of ejector-pump OTEC system was dependent on entrainment of the ejector. The degree of efficiency change was different from applied working fluid, and amount of pump work was turned out to be primary factor affected system efficiency. Meanwhile, optimized entrainment ratio was different from applied working fluid since their different vapor density. System efficiency at optimized entrainmet ratio of each working fluid was around 5%, showing minor difference each other.

Resonance analysis of cantilever porous graphene platelet reinforced pipe under external load

  • Huang, Qinghua;Yu, Xinping;Lv, Jun;Zhou, Jilie;Elvenia, Marischa Ray
    • Steel and Composite Structures
    • /
    • v.45 no.3
    • /
    • pp.409-423
    • /
    • 2022
  • Nowadays, there is a high demand for great structural implementation and multifunctionality with excellent mechanical properties. The porous structures reinforced by graphene platelets (GPLs) having valuable properties, such as heat resistance, lightweight, and excellent energy absorption, have been considerably used in different engineering implementations. However, stiffness of porous structures reduces significantly, due to the internal cavities, by adding GPLs into porous medium, effective mechanical properties of the porous structure considerably enhance. This paper is relating to vibration analysis of fluidconveying cantilever porous graphene platelet reinforced (GPLR) pipe with fractional viscoelastic model resting on foundations. A dynamical model of cantilever porous GPLR pipes conveying fluid and resting on a foundation is proposed, and the vibration, natural frequencies and primary resonant of such a system are explored. The pipe body is considered to be composed of GPLR viscoelastic polymeric pipe with porosity in which Halpin-Tsai scheme in conjunction with the fractional viscoelastic model is used to govern the construction relation of nanocomposite pipe. Three different porosity distributions through the pipe thickness are introduced. The harmonic concentrated force is also applied to the pipe and the excitation frequency is close to the first natural frequency. The governing equation for transverse motions of the pipe is derived by the Hamilton principle and then discretized by the Galerkin procedure. In order to obtain the frequency-response equation, the differential equation is solved with the assumption of small displacement, damping coefficient, and excitation amplitude by the multiple scale method. A parametric sensitivity analysis is carried out to reveal the influence of different parameters, such as nanocomposite pipe properties, fluid velocity and nonlinear viscoelastic foundation coefficients, on the primary resonance and linear natural frequency. Results indicate that the GPLs weight fraction porosity coefficient, fractional derivative order and the retardation time have substantial influences on the dynamic response of the system.

A Case Study on Sintering Characteristics of Yttria Stabilized Zirconia Powder Prepared by Two-Fluid Spray Drying

  • Choi, Jin Sam;Kong, Young-Min
    • Journal of the Korean Ceramic Society
    • /
    • v.53 no.3
    • /
    • pp.332-337
    • /
    • 2016
  • As a case study on yttria stabilized zirconia ceramics, the sintering characteristics of submicron powders and the granulation prepared by two-fluid spray drying of submicron particles were investigated. As-received powders of yttria stabilized zirconia particles were reduced to a uniform size of less than about 200 nm by repeated milling. Granulation size obtained by the two-fluid spray drying was affected by the organic matter and the primary particle size. Sintering behavior such as porosity, water absorption ratio, density, and transparency was influenced by processing conditions of the powder, and the discontinuous interfaces in a green body were reduced.

Preparation and Sinterability of Nano-Size $TiO_2$ Powders Using Supercritical Fluids (초임계 유체를 이용한 나노크기 $TiO_2$ 분말제조 및 소결특성)

  • 송정환;이정석;박인석;임대영
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.7
    • /
    • pp.625-631
    • /
    • 2000
  • In this study, the characteristics and sinterablities of TiO2 powders which were fabricated on sol-gel process and supercritical fluid process were examined. The powders fabricated on sol-gel process were amorphous. The particle size and shape were changed with the amount of water used for hydrolysis of titanium ethoxide. The powders were changed from amorphous to crystalline by heating at 400℃. The crystalline anatase TiO2 powders were directly prepared in ethanol supercritical fluid condition that temperature was 270±3℃ and pressure was 7.3 MPa. It's primary crystalline size was 20 nm and agglomerated as spherical shape whose size was 0.7∼1㎛. The powders prepared on sol-gel process were not sintered densely at 900℃ because of abnormal grain growth. However, the powders which prepared on supercritical fluid process were sintered densely at the comparatively low temperature of 800℃ by ideal growth of grain, which are fired at 900℃.

  • PDF

A RANS CFD Based Approach for Resistance, Maneuvering and Seakeeping

  • Sasanapuri, Balasubramanyam;Wilson, Wesley;Rhee, Shin-Hyung
    • Journal of Ship and Ocean Technology
    • /
    • v.11 no.4
    • /
    • pp.55-71
    • /
    • 2007
  • The primary objective of this work is to develop methodologies for virtual model basin and to demonstrate the capabilities for generic multi-hull ship geometry. A computational fluid dynamics approach is used to simulate various model basin tests for steady resistance, maneuvering and seakeeping. For a catamaran hull configuration, the methodologies are used for solving these problems and the results are discussed. Computational results are compared with the results of a benchmarked potential flow theory method for calm water resistance.

A Review of Ocean Wave Power Extraction; the primary interface

  • Nik, W.B. Wan;Muzathik, A.M.;Samo, K.B.;Ibrahim, M.Z.
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.2
    • /
    • pp.156-164
    • /
    • 2009
  • This paper aims to describe the importance of data, data collection methods, parameters to estimate the potential of wave energy and environmental impacts. The technical and economical status in wave energy conversion is outlined. Power and energy efficiency relationships are discussed. Many different types of wave-energy converters have been detailed. The progress in wave energy conversion in Malaysia is reviewed.

Is aggressive intravenous fluid prescription the answer to reduce mortality in severe pancreatitis? The FLIP study: Fluid resuscitation in pancreatitis

  • Julia McGovern;Samuel J Tingle;Northern Surgical Trainees Research Association (NOSTRA);Stuart Robinson;John Moir
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.27 no.4
    • /
    • pp.394-402
    • /
    • 2023
  • Backgrounds/Aims: Acute pancreatitis is an emergency presentation, which can range from mild to life threatening. Intravenous fluids are the cornerstone of management. Although the WATERFALL trial described the optimal fluid rate in mild/moderate pancreatitis, this trial excluded patients with moderate-severe/severe pancreatitis. The aim of this study was to establish clinical practice regarding intravenous fluid administration in acute pancreatitis and assess its effect on mortality. Methods: Prospective multi-centre audit of patients with acute pancreatitis was conducted. Data were collected regarding intravenous fluid administration within 72 hours of admission. The primary outcome was 30-day mortality. Multivariable logistic regression was used to identify predictors of 30-day mortality. Results: Those with severe pancreatitis received more fluid; median 5.7 L versus 4 L in 72 hours (p = 0.003). Participants with severe pancreatitis who died within 30 days received a median of 2,750 mL in the first 24 hours, compared to 4,000 mL in those who survived. The following factors were significant predictors of 30-day mortality: age, Glasgow score, C-reactive protein, ischaemic heart disease, and pancreatitis aetiology. Overall, volume of intravenous fluid was not associated with mortality. However, the effect of intravenous fluid volume on mortality differed significantly depending on pancreatitis severity. In severe pancreatitis, increased volume of intravenous fluid was associated with significant reductions in mortality (odds ratio = 0.655; 0.459-0.936; p = 0.020). Conclusions: In severe pancreatitis, more aggressive fluid prescription was associated with decreased mortality; however, this was not the case in milder disease. Further prospective trials guiding fluid resuscitation in severe pancreatitis are needed, as the impact of fluid on this population appears to differ from that in those with milder disease.