• 제목/요약/키워드: prevent explosive spalling

검색결과 12건 처리시간 0.02초

PP섬유 혼입 고강도 경량골재콘크리트의 내화특성 (Fire Performance of Structural Lightweight Aggregate Concrete using PP fiber)

  • 송훈;추용식;이종규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.797-800
    • /
    • 2006
  • Normally, Structural light-weight aggregate concrete(LWC) has been main used in high rise building with the object of wight loss. In spite of LWC have the advantage of light-weight, limit the use of strength restrictions by reason that explosive spalling in fire. Especially, LWC is occurred serious fire performance deterioration by explosive spalling. Thus, this study is concerned with fire performance of LWC for the purpose of using PP fibers prevent to explosive spalling. From the experimental test result, LWC is happened explosive spalling.

  • PDF

고강도 콘크리트의 폭렬발생 및 폭렬저감 메커니즘에 관한 문헌적 고찰 (A Study on the Mechanism of Explosive Spalling and Spalling Prevention Methods of High-Strength Concrete in Fire Temperature)

  • 정희진;이재영;김재환;한병찬;권영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.313-316
    • /
    • 2008
  • Nowadays, the use of high strength concrete has become increasingly popular. Thus, the theory of this study gives a definition of HSC mechanism through study factors of spalling occurrence of HSC and solutions of failure mechanism. During the fire goes on, building structure using HSC causes explosive spalling and finally it gets to the breaking of the structure down. As a result of this failure mechanism, it remains to be investigated to prevent from explosive spalling of HSC and needs to provide basic problems of HSC at high temperature.

  • PDF

Evaluation on Spalling Properties of Specimen Size with PP Fiber and Fireproof Coating

  • Kim, Gyu-Yong;Min, Choong-Siek;Lee, Tae-Gyu;Miyauchi, Hiroyuki;Park, Gyu-Yeon;Lee, Gwang-Jun
    • 한국건축시공학회지
    • /
    • 제11권4호
    • /
    • pp.353-362
    • /
    • 2011
  • High Strength Concrete (HSC) has weakness that in a fire, it is spalled and brittles. The phenomenon of spalling is made by water vapor's being confined in watertight concrete. This study is aimed to evaluate explosive spalling properties of high strength concrete with ${\square}100{\times}100{\times}200$ mm specimen and ${\square}400{\times}400{\times}1500$ mm column. To prevent spalling of concrete, fireproof coating and PP fiber are used. As a result, ${\square}400{\times}400{\times}1500$ mm column was prevented spalling likes ${\times}100{\times}100{\times}200$ mm specimen. When concrete protected failure to explosive spalling, quantity heat ratio (which fireproof coating specimen to pp fiber mixed specimen) between ${\square}100{\times}100{\times}200$ mm and ${\square}400{\times}400{\times}1500$ mm was maximum value at 20 minute, but difference of quantity heat ratio decreased and quantity heat ratio of each specimen is almost same at 30 minute.

유기섬유의 용융 및 기화에 따른 초고강도 콘크리트의 폭렬 특성 평가 (Evaluation on Spalling Properties of Ultra High Strength Concrete with Melting and Vaporization of Fiber)

  • 김규용;최경철;이주하;이승훈;이태규
    • 콘크리트학회논문집
    • /
    • 제24권2호
    • /
    • pp.173-183
    • /
    • 2012
  • 최근 고강도 콘크리트의 폭렬현상에 관한 메커니즘의 연구와 더불어 폭렬을 방지하는 방법으로써 섬유혼입에 의한 콘크리트의 수증기압을 낮추는 방법이 선호되고 있는 실정이다. 주로 단일 형태의 폴리프로필렌 섬유를 혼입하여 폭렬을 저감하는 방법들이 사용하고 있으나 초고강도 콘크리트 영역에서는 실제로 급격하게 온도가 상승하는 경우에 있어서 폭렬 및 급격한 수증기 팽창압을 고려할 수 없다는 점을 들 수 있다. 따라서 이 연구에서는 콘크리트 내부온도상승조건에 따라 섬유의 용융점에 따른 공극의 형성 및 폭렬의 상관성을 분석하고자 하였으며, W/B 12.5%의 초고강도 콘크리트를 대상으로 용융점이 다른 PE섬유, PP섬유, 나일론섬유를 각각 0.15vol%, 0.25vol% 혼입하여 폭렬 성상, 수증기압, 시차열 중량 분석, 해석적 검토를 행하였다. 실험 결과, 동일 섬유 혼입률 조건에서 섬유의 용융점이 낮더라도 초고강도 콘크리트에서는 섬유의 기화에 의한 섬유의 중량손실이 발생하지 않으면 초기 폭렬의 방지가 어렵고, 가열시간 10분 전후의 빠른 공극을 형성하는 섬유가 폭렬의 방지에 효과적인 것으로 나타났다.

방화석고보드를 부착한 고강도 콘크리트 기둥의 내화성능 (Fire Resistance Performance of High Strength Concrete Columns with Fireproof Gypsum Board)

  • 염광수;전현규
    • 콘크리트학회논문집
    • /
    • 제22권2호
    • /
    • pp.229-235
    • /
    • 2010
  • 기존 건축물의 내화성능 보강과 화재 후 손상을 입은 구조물의 보수에 사용하기 위해 방화석고보드의 두께, 방화석고보드 적용에 따른 면적증가를 최소화하기 위한 시공방법, 종류 그리고 피복두께를 변화시켜 고강도 콘크리트의 내화성능을 평가하였다. 동일하게 제작한 8기의 고강도 콘크리트 기둥에 ISO-834 화재곡선에 따라 180분 내화시험을 실시하여 종방향철근 온도와 콘크리트의 깊이별 온도분포, 방화석고보드의 형상유지성능, 그리고 폭렬발생여부 등의 내화성능을 평가하였다. 15 mm 2장의 방화석고보드를 붙인 실험체의 경우 시공방법에 상관없이 보드가 탈락하여 폭렬이 발생하였다. 하지만, 두께가 30 mm인 경우에는 방화석고보드의 형상유지력이 손실되지 않으면 폭렬방지 및 온도제어가 가능함을 확인하였다. 폭렬발생으로 콘크리트 피복두께에 따른 효과는 비교할 수 없었으며, 보드 시공법에 따른 내화성능의 차이는 미미하다고 판단되었다.

알파형 반수석고를 혼입한 시멘트 압출 패널의 내화특성 (Fire-Resistance Property of Cement Extruding Panel Mixed with Alpha-Hemihydrate Gypsum)

  • 최덕진;이민재;신상철;김기석;김진만
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.109-110
    • /
    • 2011
  • Gypsum is an important building material used to provide fire resistance to constructions by reducing their temperature rises. As the hardened gypsum is exposed to fire, evaporation of both the free water and the chemical bond water is easier than that in the cement extruding panel. The purpose of this study is to investigate the utilizability of alpha-hemihydrate gypsum to prevent spalling failure of cement extruding panel exposed to fire. This paper reports the fire-resistance property of a controled general cement extruding panel(C100), and gypsum-cement extruding panels(C50A50, A100) according to replacement ratio of alpha-hemihydrate gypsum. As a results, it is found that A100 and C50A50 are more effective to prevent the explosive spalling failure under standard fire condition than C100.

  • PDF

섬유혼입된 50 MPa 고강도 콘크리트의 내화성능 (Fire Resistance Performance of Fiber-Cocktail Reinforced 50 MPa High Strength Concrete)

  • 염광수;전현규;박종헌
    • 한국재난관리표준학회지
    • /
    • 제2권3호
    • /
    • pp.55-60
    • /
    • 2009
  • 현재 많이 사용되고 있는 50MPa 고강도 콘크리트에 대해서 섬유혼입공법(폴리프로필렌섬유와 강섬유)을 적용하여 국토해양부 시행령에 따라 2가지 다른 섬유혼입량을 가진 총 4기의 시험체를 제작하여 ISO 834 표준내화곡선에 따라서 180분간 내화시험을 실시하여 폭렬발생여부, 철근과 콘크리트의 온도분포를 통해 내화성능을 평가하였다. 내화시험 후 모든 시험체에 폭렬은 발생하지 않았으며, 폭렬방지를 위해서 요구되는 최소 폴리프로필렌섬유량은 콘크리트 단위용적당 0.57 kg이상 이다. 섬유혼입량에 따른 콘크리트와 종방향철근의 온도분포를 비교한 결과, 섬유혼입량에 따른 차이는 없다고 판단된다.

  • PDF

고온 및 하중에 따른 섬유혼입 콘크리트의 잔존역학적 특성에 관한 연구 (A Study on the Residual Mechanical Properties of Fiber Mixed Concrete with High Temperature and Load)

  • 윤대기;김규용;최경철;이태규;구경모;김홍섭
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.119-120
    • /
    • 2011
  • Recently, the effects of high temperature and fiber content on the residual mechnical properties of high-strength concrete were experimentally investigated. In this paper, residual mechanical properties of concrete with water to cement (w/c) ratios of 55%, 42% and 32% exposed to high temperature are compared with those obtained in fiber reinforced concretes of similar characteristics with the ranging of 0,05% to 0,20% polypropylene (PP) fibers by volume of concrete, and considered factors include pre-load levels (20% and 40% of the maximum load at room temperature). Outbreak time and water contents were tested and were determined the compressive strength. In the result, it is showed that to prevent the explosive spalling of 50MPa grade concretes exposed to high temperature need more than 0.05Vol.% PP fibers. Also, the cross-sectional area of PP fiber can influence on the residual mechanical properties and the spalling tendency of fiber reinforced concrete exposed to high temperature. Especially, the external loading increases not only the residual mechanical properties of concrete but also the risk of spalling and the brittle tendency.

  • PDF

섬유혼입공법을 적용한 고강도콘크리트 기둥의 비재하 내화시험 (Fire Test of Fiber Cocktail Reinforced High Strength Concrete Columns without Loading)

  • 염광수;전현규;김흥열
    • 콘크리트학회논문집
    • /
    • 제21권4호
    • /
    • pp.465-471
    • /
    • 2009
  • 화재시 고강도콘크리트의 폭렬현상을 막고 내부철근 온도의 상승을 억제하기 위하여 폴리프로필렌섬유와 강 섬유를 동시에 사용하는 섬유혼입공법을 제안하였다. 섬유혼입공법을 40~100 MPa 고강도콘크리트 배합에 적용하여 가 열재하방법으로 열적특성을 평가한 후 내화성능을 평가하기 위하여 구조부재에 내화시험을 실시하였다. 2기의 기둥시 험체를 제작하여 ISO 834 표준내화곡선에 따라 180분 비재하 내화시험을 실시하였다. 폭렬은 발생하지 않았으며, 표면 부의 색은 분홍색을 띤 회색으로 변했다. 깊이 60 mm부터 내부 콘크리트의 온도가 급감하였으며, 60분 가열 후 온도구 배는 보통콘크리트보다 5배 적은 2.2oC/mm로 측정되었다. 180분 내화시험 후의 최종온도는 모서리철근이 488.0oC, 중앙 철근이 350.9oC이며, 철근의 총 평균온도는 419.5oC이다. 모서리철근과 중앙철근의 평균온도차는 137.1oC였다. 가열 후 100~150oC부근에서 콘크리트와 철근의 온도상승추세가 변하는데 이는 강섬유와 폴리프로필렌섬유를 혼입한 콘크리트의 온도구배가 낮고, 철근으로의 수분이동과 내부 수분의 막힘현상, 그리고 수분의 기화열 때문이다.

고온을 받은 나일론 섬유 보강 고강도 콘크리트의 크리프 거동 (Creep Behavior of High-Strength Concrete with Nylon Fibers at Elevated Temperatures)

  • 김영선;이태규;김우재;김규용
    • 콘크리트학회논문집
    • /
    • 제23권5호
    • /
    • pp.627-636
    • /
    • 2011
  • 최근 고강도 콘크리트의 폭렬 방지용 보강 섬유로서 폴리프로필렌 섬유를 대신하여 나일론 섬유의 사용이 증가됨에 따라 고온에 노출된 나일론 섬유를 혼입한 고강도 콘크리트의 폭렬 및 역학적 특성에 관한 실험적 연구가 수행되고 있다. 그러나, 고온을 받은 나일론 섬유 보강 고강도 콘크리트에 관한 연구는 주로 폭렬 특성, 압축강도 및 탄성계수에 대한 평가만이 수행되고 있으며, 열팽창 변형, 전체 변형, 크리프 변형 및 과도 변형과 같은 거동은 평가된 바가 없다. 따라서 이 연구에서는 W/B 0.30~0.15에 따른 나일론 섬유를 혼입한 고강도 콘크리트에 대하여 열팽창 변형, 전체 변형, 크리프 및 과도 변형 등을 평가하였다. 실험 결과, 나일론 섬유는 고온을 받은 나일론 섬유를 혼입한 고강도 콘크리트의 성능에 특별한 영향을 미치지 않는 것으로 보였으며, 나일론 섬유 보강 고강도 콘크리트는 섬유를 혼입하지 않은 고강도 콘크리트 또는 보통 강도 콘크리트보다 큰 과도 변형을 나타냈다.