• Title/Summary/Keyword: prestressing tendons

검색결과 118건 처리시간 0.031초

PSC 박스거더교 정착부의 최소파열력에 대한 강선긴장순서 (Minimization of Bursting Force at Anchorage Zone Using Prestressing Order for PSC Box Girder Bridge)

  • 정지승;구형선
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권2호
    • /
    • pp.103-109
    • /
    • 2001
  • In this paper, the prestressing order of tendons is studied to minimize a bursting force of an anchorage. The bursting forces is a primary factor of anchorage failures. The forces of the anchorage depend on the prestressing order and size of the tendons, if a lot of tendons are introduced to the anchorage. Many studies have been made to analyze the bursting force of the anchorage. However, the studies have been limited to the bursting forces of the anchorage having one or two tendons. PSC box girder bridges usually have a lot of tendons. And the difference of the bursting forces lies in the prestressing order of the tendons. As a result of the lack of studies on the prestressing order for the bridges, the order depends on the designer's intuition and experiences. It may be stated that this study should be useful for determining the reasonable prestressing order of tendons for the PSC box girder bridges.

  • PDF

원형탱크구조물 벽체의 텐던 배치에 대한 고찰 (Effect of Arrangement of the Prestressing Tendons in the Wall of Circular Storage Tank)

  • 전세진;정철헌;진병무;김성운
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.513-518
    • /
    • 2002
  • Prestressing tendons in the wall of circular storage tank were investigated from the viewpoint of equivalent load method. Special attention was paid to the effectiveness of eccentricities of the circumferential and vertical tendons. Some aspects which are frequently overlooked or misinterpreted in the analysis of vertical tendons are discussed. It is expected that the equivalent load method can be effectively used to simplify the analysis of tendons in the circular wall thus to minimize the errors.

  • PDF

Behaviour of continuous prestressed concrete beams with external tendons

  • Chan, K.H. Enoch;Au, Francis T.K.
    • Structural Engineering and Mechanics
    • /
    • 제55권6호
    • /
    • pp.1099-1120
    • /
    • 2015
  • External prestressing has been applied to both new construction and retrofitting of existing reinforced and prestressed concrete structures. Continuous beams are preferred to simply supported beams because of economy, fewer movement joints and possible benefits from moment redistribution. However, this paper argues that continuous prestressed concrete beams with external unbonded tendons demonstrate different full-range behaviour compared to reinforced concrete (RC) beams. Applying the same design approach for RC to external prestressing may lead to design with a lower safety margin. To better understand the behaviour of continuous prestressed concrete beams with unbonded tendons, an experimental investigation is performed in which nine such specimens are tested to failure. The full-range behaviour is investigated with reference to moment-curvature relationship and moment redistribution. The amounts of moment redistribution measured in the experiments are compared with those allowed by BS 8110, EC2 and ACI 318. Design equations are also proposed to estimate the curvature ductility index of unbonded prestressed concrete beams.

금속계열선의 전기기계적 상관작용과 긴장력 계측이 가능한 긴장재 (Electromechanical Relationn of metallic heat wires and Its Application to the Estimation of In_situ Stress of Structural Tendons)

  • 지광습;전기우
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.445-450
    • /
    • 2006
  • It is proposed that the electromechanical relation of the conductive materials with high electrical resistance may be used to estimate the current stress of prestressing tendons. To choose the best conductive material to this end, we studied the electromechanical relations of carbon fibers and metalic heat wires experimentally. It is found that the relation of carbon fibers can be modelled by a parabolic(or hyperbolic) function in the early stage of deformation. However because the relation is not consistent when it is unloaded and reload, carbon fibers are not suitable for this purpose. Metallic heat wires show a consistent linear relation during loading and unloading in the elastic deformation and are suitable for this purpose. To estimate the electromechanics relation of metallic wires, we developed a simple formula based on the rigid plasticity. We propose a new kind of prestressing tendons whose stress can be monitored.

  • PDF

연속화와 외부 프리스트레스 도입에 의한 노후된 콘크리트 거더교의 성능향상에 관한 연구 (A Study on Performance Elevation of the deteriorated Concrete Girder Bridge by Continuous and External Tendons)

  • 박승범;홍석주
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제4권2호
    • /
    • pp.159-166
    • /
    • 2000
  • The development of external prestressing methods has been one of the major trends in the concrete bridge constructions over the past decades. One of the promising methods to enhance the flexural strength of a externally prestressed girder is to place the tendons with large eccentricities. The analysis and design of composite girders prestressed by external tendons involve difficulties related mainly to the position of anchorages and the construction sequences. This study was conducted on the concrete bridges reinforced by the continuous girders and the external prestressing. The test results in this study showed that the external prestressing of a composite girder increased the range of the elastic behavior, reduced deflections, increased ultimate strength, and added to the redundancy by providing the multiple stress paths.

  • PDF

PSC 교량 정착부의 강선긴장순서에 대한 수치해석 연구 (Numerical Analysis at Anchorage Zone Using Prestressing Order for PSC Bridges)

  • 조병완;태기호;오세준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권5호
    • /
    • pp.97-105
    • /
    • 2006
  • 일반적으로 PSC 교량은 여러개의 강선을 포함하며, 이러한 강선들의 긴장순서에 따라 정착부의 파열력의 크기는 좌우된다. 그럼에도 불구하고 강선긴장순서에 대한 연구부족으로 강선긴장시 긴장순서를 설계자의 경험이나 직관에 의하여 결정하고 있다. 본 연구에서는 정착부의 파열력을 산정하는 여러 방법에 대하여 고찰한 후, 가장 합리적인 해석방법을 선택하여 PSC 교량중에서 가장 대표적인 PSC빔교와 PSC박스거더교에 대하여 해석을 통한 합리적인 긴장순서를 결정하였다. 본 연구에서 제시한 방법은 PSC교량 정착부의 파열력을 최소화하는 강선긴장순서 결정에 유용한 방법이 될 것이다.

Flexural Behavior of Continuous Composite Bridges with Precast Concrete Decks

  • Chung, Chul-Hun
    • 콘크리트학회논문집
    • /
    • 제15권4호
    • /
    • pp.625-633
    • /
    • 2003
  • For the construction of open-topped steel box girder bridges, prefabricated concrete slab could offer several advantages over cast-in-situ deck including good quality control, fast construction, and elimination of the formwork for concrete slab casting. However, precast decks without reinforcements at transverse joints between precast slabs should be designed to prevent the initiation of cracking at the joints, because the performance of the joint is especially crucial for the integrity of a structural system. Several prestressing methods are available to introduce proper compression at the joints, such as internal tendons, external tendons and support lowering after shear connection. In this paper, experimental results from a continuous composite bridge model with precast decks are presented. Internal tendons and external tendons were used to prevent cracking at the joints. Judging from the tests, precast decks in negative moment regions have the whole contribution to the flexural stiffness of composite section under service loads if appropriate prestressing is introduced. The validity of the calculation of a cracking load fur serviceability was presented by comparing an observed cracking load and the calculated value. Flexural behavior of the continuous composite beam with external prestressing before and after cracking was discussed by using the deflection and strain data.

FRP 긴장재로 외부 보강된 철근콘크리트 보의 피로거동 (Fatigue Behavior of Reinforced Concrete Beams Externally Strengthened using FRP Tendons)

  • 박상렬;홍성룡;김창훈
    • 대한토목학회논문집
    • /
    • 제28권6A호
    • /
    • pp.809-817
    • /
    • 2008
  • 최근 사용되고 있은 구조물의 보강 방법 중 내력 및 사용성 향상효과가 타 공법에 비해 월등한 외부 긴장공법이 많이 사용되고 있다. 그러나 외부 긴장재로 보강된 구조물에 대하여 반복하중에 의한 피로 성능에 대한 평가가 부족하고 이에 대한 연구도 매우 부족한 실정이다. 따라서 본 연구에서는 FRP 긴장재로 외부 보강된 철근콘크리트 보의 반복하중에 따른 피로거동 특성을 분석함으로써 외부 긴장공법의 안전성 및 타당성을 평가하고자 하였다. 본 실험연구에서는 비교 변수로 외부 긴장재의 종류(FRP 긴장재, Steel 긴장재)와 하중범위를 채택하여 실험을 실시하였다. 하중은 FRP 보강 시험체의 항복강도를 기준으로 최소하중을 50%로 삼고 최대하중을 70~85%로 변경하여 4점 재하방식으로 sine파를 이용하여 3Hz의 주기로 실험을 실시하였다. FRP 긴장재로 외부 보강된 철근콘크리트 보에 대한 피로 실험연구 결과로부터 FRP 외부 긴장 공법은 FRP 긴장재, deviator에서의 절곡부, 정착장치 등에서 피로에 대한 충분한 안전성이 확인되었다.

연속음향감지기법을 이용한 긴장력이 감소된 10 m PSC보의 PS 강선 파단음파 감지 (Detection of Fracture Signals of Low Prestressed Steel Wires in a 10 m PSC Beam by Continuous Acoustic Monitoring Techniques)

  • 윤석구;이창노
    • 콘크리트학회논문집
    • /
    • 제22권1호
    • /
    • pp.113-122
    • /
    • 2010
  • 후 긴장된 PS 강재의 부식과 파단은 프리스트레스 콘크리트 교량의 안전에 매우 심각한 문제를 발생시키고 있다. 따라서 교량의 내하력 평가시 PS 강재의 부식 상태를 조사해야 하며, 부식된 PS 강재가 발견되는 경우, 부식에 의한 강재의 단면적 감소량을 극한강도 평가시 고려해야만 한다. 선행 연구에서는 연속음향감지기법을 그라우팅되고 후 긴장된 PS 강연선의 부식과 파단을 감지할 수 있는 신뢰할 만한 비파괴검사방법으로 평가하였다. 이 연구에서는 긴장재에 도입된 응력 수준이 현행 설계기준에 제시된 수준보다 낮게 도입된 PS 강연선에 대해 부식에 의한 강선 파단을 감지하기 위한 실험적 연구를 수행하였다. 이를 위해 프리스트레스의 크기가 각각 인장강도의 66%와 40%로 도입된 PS 강연선이 포함된 길이 10 m의 PSC 보를 제작하였다. 부식 촉진 장비를 이용하여 긴장재를 인위적으로 부식시켰으며, 7개의 음향센서와 연속음향감지장치를 이용하여 실험부재를 모니터링하였다. 부식 촉진 실험 동안 각 PS 강연선으로부터 2번의 강선 파단음파를 성공적으로 감지하였으며, 또한 오차범위 20 mm 이하로 음원 위치를 표정할 수 있었다. 이상의 실험 결과를 토대로 그라우팅되고 후 긴장된 PSC 보에서 발생되는 PS 강선 파단을 감지하는데 연속음향감지기법을 적용할 수 있다고 판단된다.

외부 프리스트레싱으로 보강된 프리스트레스트 콘크리트 보에서 프리스트레싱 강재의 극한응력 (Ultimate Stress of Prestressing Steel in Prestressed Concrete Beams Strengthened by External Prestressing)

  • 박상렬
    • 콘크리트학회논문집
    • /
    • 제16권5호
    • /
    • pp.677-686
    • /
    • 2004
  • 본 연구는 외부 프리스트레싱으로 보강된 내부 프리스트레스트 콘크리트 보에 관한 문헌연구와 프리스트레싱 강재의 극한응력 예측식의 개발, 극한응력에 영향을 미치는 변수들에 대한 실험 등이다. 본 논문에서는 내부 및 외부 프리스트레싱 강재의 극한응력에 대한 새로운 합리적 예측식을 제안하고 있는데, 프리스트레싱 강재와 중립축 깊이비의 함수로 표현하여 내부 및 외부 프리스트레싱 강재의 영향을 고려하고 있다. 실험연구에서는 내부 및 외부 프리스트레싱 강재의 극한응력에 가장 큰 영향을 미치는 실험변수를 가지고 외부 프리스트레싱으로 보강된 프리스트레스트 콘크리트 보를 제작하여 실험하였다. 실험연구에서 채택한 영향인자들은 내부 프리스트레싱 강재량, 외부 프리스트레싱 강재량, 지간과 프리스트레싱 강재 높이비 등이다. 실험결과는 분석되어 내부 및 외부 프리스트레싱 강재의 극한응력 예측 제안식의 합리성 적용성을 확인하였다. 본 연구는 제안된 응력 예측식이 실험에서 얻은 실측값들과 잘 일치함을 보여주고 있다.