Abstract

The development of external prestressing methods has been one of the major trends in the concrete bridge constructions over the past decades. One of the promising methods to enhance the flexural strength of a externally prestressed girder is to place the tendons with large eccentricities. The analysis and design of composite girders prestressed by external tendons involve difficulties related mainly to the position of anchorages and the construction sequences. This study was conducted on the concrete bridges reinforced by the continuous girders and the external prestressing. The test results in this study showed that the external prestressing of a composite girder increased the range of the elastic behavior, reduced deflections, increased ultimate strength, and added to the redundancy by providing the multiple stress paths.

Keywords