• 제목/요약/키워드: prestressed structure

검색결과 174건 처리시간 0.018초

스트럿-타이 모델을 이용한 프리스트레스트 더블 T형 보의 정착부 거동 연구 (A Study on Behavior for Anchorage Zone in Prestressed Double T Beam Using Strut-Tie Model)

  • 김종욱;이두성;민창식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.425-430
    • /
    • 2002
  • This thesis is a study on behavior for anchorage zone in prestressed double T beam using strut-tie model. Stress conditions of Anchorage zone in prestressed double T beam are very disturbed because large concentrated forces act on relatively small areas. Hence, anchorage zone must be considered in Design of prestressed double T beam. If irrational design or irrational construction be conducted, that may lose stability in capacity as structure. In current design practice, certain parts of structure are designed with extreme accuracy, while anchorage zone in prestressed double T beam is designed using common sense, and experience. Therefore, it is generally very conservative. For that reason, logical, reasonable concept and accuracies are desired at design of anchorage zone in prestressed double T beam. Strut-tie method satisfies those desires. In this thesis, anchorage zone in prestressed double T beam is analyzed by considering prestressing forces. Strut-tie model is constructed based on principle stress trajectory obtained from 3D-finite element analysis in anchorage zone, and amounts of reinforcement be obtained. Results of analysis are compared with the way used in current design practice, and this thesis presents that strut-tie model can be an economical design than current design methods without losing the degree of safety.

  • PDF

In-plane seismic performance of masonry wall retrofitted with prestressed steel-bar truss

  • Hwang, Seung-Hyeon;Kim, Sanghee;Yang, Keun-Hyeok
    • Earthquakes and Structures
    • /
    • 제19권6호
    • /
    • pp.459-469
    • /
    • 2020
  • An external prestressed steel-bar truss unit was developed as a new strengthening technology to enhance the seismic performance of an in-plane masonry wall structure while taking advantage of the benefits of a prestressed system. The presented method consists of six steel bars: two prestressed vertical bars to introduce a prestressing force on the masonry wall, two diagonal bars to resist shear deformation, and two horizontal bars to maintain the configuration. To evaluate the effects of this new technique, four full-scale specimens, including a control specimen, were tested under combined loadings that included constant-gravity axial loads and cyclic lateral loads. The experimental results were analyzed in terms of the shear strength, initial stiffness, dissipated energy, and strain history. The efficiency of the external prestressed steel-bar truss unit was validated. In particular, a retrofitted specimen with an axial load level of 0.024 exhibited a more stable post behavior and higher energy dissipation than a control specimen with an observed complete sliding failure. The four vertical bars of the adjacent retrofitting units created a virtual column, and their strain values did not change until they reached the peak shear strength. The shear capacity of the masonry wall structure with external prestressed steel-bar truss units could be predicted using the model suggested by Yang et al.

Fatigue performance monitoring of full-scale PPC beams by using the FBG sensors

  • Wang, Licheng;Han, Jigang;Song, Yupu
    • Smart Structures and Systems
    • /
    • 제13권6호
    • /
    • pp.943-957
    • /
    • 2014
  • When subjected to fatigue loading, the main failure mode of partially prestressed concrete (PPC) structure is the fatigue fracture of tensile reinforcement. Therefore, monitoring and evaluation of the steel stresses/strains in the structure are essential issues for structural design and healthy assessment. The current study experimentally investigates the possibility of using fiber Bragg grating (FBG) sensors to measure the steel strains in PPC beams in the process of fatigue loading. Six full-scale post-tensioned PPC beams were exposed to fatigue loading. Within the beams, the FBG and resistance strain gauge (RSG) sensors were independently bonded onto the surface of tensile reinforcements. A good agreement was found between the recorded results from the two different sensors. Moreover, FBG sensors show relatively good resistance to fatigue loading compared with RSG sensors, indicating that FBG sensors possess the capability for long-term health monitoring of the tensile reinforcement in PPC structures. Apart from the above findings, it can also be found that during the fatigue loading, there is stress redistribution between prestressed and non-prestressed reinforcements, and the residual strain emerges in the non-prestressed reinforcement. This phenomenon can bring about an increase of the steel stress in the non-prestressed reinforcement.

Numerical analysis of second-order effects of externally prestressed concrete beams

  • Lou, Tiejiong;Xiang, Yiqiang
    • Structural Engineering and Mechanics
    • /
    • 제35권5호
    • /
    • pp.631-643
    • /
    • 2010
  • A numerical procedure for the geometrical and material nonlinear analysis of concrete beams prestressed with external tendons is described, where the effects of external prestressing are treated as the equivalent loads applied on the concrete beams. The geometrical nonlinearity is considered not only the eccentricity variations of external tendons (second-order effects) but also the large displacement effects of the structure. The numerical method can predict the nonlinear response of externally prestressed concrete beams throughout the entire loading history with considerable accuracy. An evaluation of second-order effects of externally prestressed concrete beams is carried out using the proposed analysis. The analysis shows that the second-order effects have significant influence on the response characteristics of externally prestressed concrete beams. They lead to inferior ultimate load and strength capacities and a lower ultimate stress increase in tendons. Based on the current analysis, it is recommended that, for simply-supported externally prestressed beams with straight horizontal tendons, one deviator at midspan instead of two deviators at one-third span be furnished to minimize these effects.

Hybrid vibration-impedance monitoring in prestressed concrete structure with local strand breakage

  • Dang, Ngoc-Loi;Pham, Quang-Quang;Kim, Jeong-Tae
    • Smart Structures and Systems
    • /
    • 제30권5호
    • /
    • pp.463-477
    • /
    • 2022
  • In this paper, a hybrid vibration-impedance-based damage monitoring approach is experimentally evaluated for prestressed concrete (PSC) structures with local strand breakage. Firstly, the hybrid monitoring scheme is designed to alert damage occurrence from changes in vibration characteristics and to localize strand breakage from changes in impedance signatures. Secondly, a full-scale PSC anchorage is experimented to measure global vibration responses and local impedance responses under a sequence of simulated strand-breakage events. Finally, the measured data are analyzed using the hybrid monitoring framework. The change of structural condition (i.e., damage extent) induced by the local strand breakage is estimated by changes in a few natural frequencies obtained from a few accelerometers in the structure. The damaged strand is locally identified by tomography analysis of impedance features measured via an array of PZT (lead-zirconate-titanate) sensors mounted on the anchorage. Experimental results demonstrate that the strand breakage in the PSC structure can be accurately assessed by using the combined vibration and impedance features.

Time-dependent Material Properties in FCM Segment of Prestressed Concrete Box-Girder Bridge

  • Yoon, Young-Soo;Choi, Han-Tae;Kwon, Soon-Beom
    • KCI Concrete Journal
    • /
    • 제11권3호
    • /
    • pp.99-107
    • /
    • 1999
  • In designing the Prestressed concrete box-girder bridge. dead load, prestressing force, creep and shrinkage of concrete are the main factors which influence the camber and deflection of segmental concrete structure under construction. Among these factors the creep and shrinkage are the functions of the time-dependent property which. therefore, must be considered with time. The prediction model for estimating creep and shrinkage of concrete has been suggested by ACI, CEB/FIP, JSCE and KSCE design code and EMM, AEMM, RCM, IDM and SSM has been suggested for analytical method in consideration of time-dependent characteristics. In this study the creep test was carried out for four different curing ages of concrete which were applied to the Prestressed concrete structure at the construction site, and the results of test were compared with the values of creep prediction proposed by the design code. Also the creep test was performed with step-wise incremental stresses and the results were compared to the analytical values.

  • PDF

프리캐스트 콘크리트 교각의 구조거동에 관한 실험적 연구 (An Experimental Study for the Structural Behavior of the Precast Prestressed Concrete Columns)

  • 최승원;신현목;이재훈;오병환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.146-149
    • /
    • 2006
  • In many previous studies, a prestressed concrete column has a larger flexural strength, shear strength and restoring force than a RC column. Recently, a precast prestressed concrete column is rising up a very rational column structure in that a economic aspect. In a precast prestressed concrete column, it makes in a factory. So, it needs a small construction site and acquires a higher durability than a cast in place concrete column. Seven precast concrete columns were tested under a constant axial load and a cyclically reversed horizontal load to investigate the performance. It is designed with a hollow section and consisted of 4 segments. The main variables of the test were a amount of prestressed, a type of joints and a boding type of strands. The test results show that the performance of a precast prestressed concrete column; failure mode, maximum load, energy dissipation and stiffness degradation.

  • PDF

Semi-active control on long-span reticulated steel structures using MR dampers under multi-dimensional earthquake excitations

  • Zhou, Zhen;Meng, Shao-Ping;Wu, Jing;Zhao, Yong
    • Smart Structures and Systems
    • /
    • 제10권6호
    • /
    • pp.557-572
    • /
    • 2012
  • This paper focuses on the vibration control of long-span reticulated steel structures under multi-dimensional earthquake excitation. The control system and strategy are constructed based on Magneto-Rheological (MR) dampers. The LQR and Hrovat controlling algorithm is adopted to determine optimal MR damping force, while the modified Bingham model (MBM) and inverse neural network (INN) is proposed to solve the real-time controlling current. Three typical long-span reticulated structural systems are detailedly analyzed, including the double-layer cylindrical reticulated shell, single-layer spherical reticulated shell, and cable suspended arch-truss structure. Results show that the proposed control strategy can reduce the displacement and acceleration effectively for three typical structural systems. The displacement control effect under the earthquake excitation with different PGA is similar, while for the cable suspended arch-truss, the acceleration control effect increase distinctly with the earthquake excitation intensity. Moreover, for the cable suspended arch-truss, the strand stress variation can also be effectively reduced by the MR dampers, which is very important for this kind of structure to ensure that the cable would not be destroyed or relaxed.

시공단계의 영향을 고려한 프리스트레스 콘크리트 다층 구조물의 해석 (Analysis of Multi-Story Prestressed Concrete Structure Considering the Effect of Construction Stage)

  • 전찬기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권3호
    • /
    • pp.213-223
    • /
    • 2001
  • This paper presents an analytical procedure for the time-dependent analysis of the multi-story prestressed concrete structure under the construction stage. To account for the actual structural behavior, the procedure considers the effects due to the construction interval and the time-dependent losses of prestress at every construction step on the entire structural response. A numerical study is performed to demonstrate the general validity of the approach and to quantitatively evaluate the effects resulted from the time-dependent behaviors during construction. Recommendations and conclusions are developed by comparisons with structural responses using the present and conventional methods of analysis. The comparative results show that both effects of sequential construction and time-dependent prestress losses should be considered for the construction stage analysis.

  • PDF

모델차수축소법을 이용한 프리스트레스 구조물의 효율적인 고유진동해석 (Efficient Modal Analysis of Prestressed Structures via Model Order Reduction)

  • 한정삼
    • 대한기계학회논문집A
    • /
    • 제35권10호
    • /
    • pp.1211-1222
    • /
    • 2011
  • 일반적으로 회전체나 초기 하중 하의 구조물 또는 열변형된 파이프 등의 프리스트레스 구조물은 이러한 프리스트레스 효과로 인하여 고유진동수 및 고유진동모드가 변화되기 때문에 정확한 고유진동해석을 위해서는 프리스트레스 고유진동해석을 수행해야 한다. 시스템에 따라서는 그 복잡성으로 인하여 수십만~수백만의 큰 자유도를 갖는 대형 유한요소모델이 요구되어 이러한 대형 모델의 프리스트레스 영향을 파악하기 위한 프리스트레스 고유진동해석을 주어진 설계시간 내에 반복적으로 수행하기에는 여전히 시간적 어려움이 많은 형편이다. 따라서, 본 논문에서는 크리로프 부공간에 근거한 축소기법으로 시스템의 초기 유한요소모델에 대하여 고유진동 특성을 정확하게 나타내면서도 작은 차수의 축소모델로 표현하여 프리스트레스 고유진동해석에서의 계산시간 문제를 감소하였다. 초기 시스템과 축소 시스템의 모멘트를 일치하는 수치계산에는 아놀디 과정을 이용하였다. 적용예제로 휠과 컴프레서 임펠러를 선택하여 제안한 방법을 통한 회전에 따른 프리스트레스 고유진동해석의 정확성과 효율성을 보였다.