• Title/Summary/Keyword: pressurized treatment

Search Result 106, Processing Time 0.068 seconds

Thermal Destruction of Waste Insulating Oil Containing PCBs under High Temperature and Pressurized Conditions

  • Seok, Min-Gwang;Lee, Gang-Woo;Lee, Jae-Jeong;Kim, Min-Choul;Kim, Yang-Do;Jung, Jong-Hyeon;Shon, Byung-Hyun
    • Environmental Engineering Research
    • /
    • 제17권3호
    • /
    • pp.157-165
    • /
    • 2012
  • This experimental study was performed to obtain thermal energy from the combustion of synthetic gas, produced by the pyrolysis of insulating oil containing polychlorinated biphenyls (PCBs) in a high temperature and high pressure reactor. The average synthetic gas generated was $59.67Am^3/hr$ via the steady state gasification of insulating oil waste (20 kg/hr) with average concentrations (standard deviation) of $CO_2$, CO, and $H_2$ in the synthetic gas of $38.63{\pm}3.11%$, $35.18{\pm}1.93%$, and $28.42{\pm}1.68%$, respectively. The concentrations of the PCBs in the transformer insulating oil and synthetic gas after its gasification, and the concentrations of the dioxins that could be produced from the incomplete degradation of PCBs were measured. It was revealed that the PCBs in the insulating oil were composed of the series from tetrachlorobiphenyl to octachlorobiphenyl. However, only the #49, #44, #52, and #47/75/48 congeners were detected from the synthetic gas after gasification of the insulating oil and in the flue gas from the combustor. In conclusion, the experimental conditions suggested in this study were very useful for the appropriate treatment of insulating oil containing PCBs. Also, fuel gas containing CO and $H_2$ can be obtained from the pyrolysis of insulating oil containing PCBs.

물통합형 정삼투 시스템을 이용한 파일럿 스케일 담수 공정 모사 (Pilot-Scale Simulation of Desalination Process Using Water Integrated Forward Osmosis System)

  • 김봉철;홍승관;최준석
    • 한국물환경학회지
    • /
    • 제33권4호
    • /
    • pp.403-408
    • /
    • 2017
  • In these days, wastewater reclamation and seawater desalination play essential role in addressing the challenge of worldwide water scarcity. Particularly, reverse osmosis (RO) for seawater desalination process is commonly used due to less energy consumption than conventional thermodynamic systems. However, membrane fouling and electrical energy consumption during operation of RO system for seawater desalination haver continued to be a obstruction to its application. In this study, therefore, wastewater secondary effluent is used for osmotic dilution of seawater. Firstly, fouling behaviour of RO by simulating wastewater effluent in osmotic dilution process was measured and we calculated energy consumption of overall desalination process by theoretical equations and commercial program. Our results reveal that RO membrane fouling can be efficiently controlled by pre-treatment systems such as nano filtration (NF) or forward osmosis (FO) process. Especially FO system for osmotic dilution process is a non-pressurized membrane system and, therefore, the operating energy consumption of overall desalination system was the lowest. Moreover, fouling layer on FO membrane is comparatively weak and reversible enough to be disrupted by physical cleaning. Thus, RO system with low salinity feed water through FO process is possible as a less energy consuming desalination system with efficient membrane fouling control.

고압처리에 의한 Candida tropicalis의 불활성화 및 세포구조의 변화 (High Pressure Inactivation of Candida tropicalis and Its Effects on Ultrastructure of the Cells)

  • 손경현;장정국;공운영;이형주
    • 한국식품과학회지
    • /
    • 제28권3호
    • /
    • pp.587-592
    • /
    • 1996
  • 과일쥬스의 변패에 관여하는 Candida tropicalis에 대하여 고압처리에 의한 사멸과 미생물의 미세구조에 미치는 압력의 영향을 조사하였다. C. tropicalis의 가압사멸은 1차 반응을 따르며, $25^{\circ}C-400\;MPa$에서 D값은 1.4분이었고, z값은 100 MPa이었다. 고압처리에 의한 살균효과는 $25^{\circ}C$에서보다 $45^{\circ}C$에서 높게 나타났다. $25^{\circ}C$에서 400MPa, 10분 고압처리로 C. tropicalis는 미토콘드리아막과 세포벽이 변형되었다. 다라서 고압처리에 의한 세포막, 원형질막 등의 변형이 미생물 가압사멸의 원인이 되는 것으로 판단된다.

  • PDF

가압식 비침습적 대뇌 혈류 증가 장치의 구현 (Implementation of Non-Invasive Pressurized Cerebral Perfusion Platform)

  • 이진;유형곤;김영길
    • 한국정보통신학회논문지
    • /
    • 제21권9호
    • /
    • pp.1752-1760
    • /
    • 2017
  • 뇌경색의 대표적인 치료법과 예방법중 하나는 대뇌혈류를 증가시키는 방법이다. 대뇌 부위로 가는 혈류량을 우회적으로 증가시켜 최종대뇌 손상부위를 최소화 하는 것을 목표로 한다. 이와 같은 대뇌 혈류를 증가시키는 방법은 약물에 의한 치료방법과, 수술에 의한 방법 등 칩습적으로 행해져왔다. 하지만 이러한 침습적인 방법은 환자에게 수술의 부담을 주며 합병증 등의 위험에 노출되어 있는 단점이 있다. 본 논문에서는 이러한 침습적인 치료방법의 단점을 보완하고자 비침습적 대뇌 혈류 증가 장치를 제안한다. 기존의 대뇌 혈류 증가 장치의 단점을 보완하기 위해 가압식 측정법을 적용하여 환자의 사지 혈압을 정확하게 측정하고 사지압박을 실시하여 대뇌부위로 가는 혈류량을 우회적으로 증가시켜 혈류증강 치료를 실시한다. 이는 기존의 침습적 대뇌혈류증강 치료와 비교하여 합병증의 우려가 없고 환자에게 부담을 주지 않으며 대뇌혈류량을 의미 있게 증가시키기 때문에 환자에게 선택적으로 사용될 수 있다.

침지식 MBR을 이용한 수산물 폐수처리장 운영에 관한 연구 (A Study on Management of Seafood Wastewater Treatment Facility using Submerged MBR)

  • 최용범;이해승;한동준;권재혁
    • 한국산학기술학회논문지
    • /
    • 제16권11호
    • /
    • pp.7227-7236
    • /
    • 2015
  • 수산물 가공폐수의 배출특성 결과, 불규칙한 유입부하로 안정적인 처리에 어려움이 있는 것으로 조사되었다. 수산물 가공폐수와 같은 고농도 유기성 폐수처리에는 가압부상조 운영이 매우 중요하다. 가압부상조의 운전 factor를 조사한 결과, A/S ratio 0.05(설계기준 0.01), 가압공기 압력은 8bar(설계기준 6bar), 가압탱크 압력은 6bar(설계기준 4.5bar), HRT는 60sec(설계기준 10sec)로 운영하였다. 또한 재순환율은 40% 이상(설계기준 30%), 표면 부하율은 $13.7m^3/m^2{\cdot}hr$ 이하(설계기준 $17.7m^3/m^2{\cdot}hr$ 이하)로 변경하여 최초 설계기준에 비하여 운전 factor를 유입특성에 따라 변화시켜 가압부상조의 성능을 향상시켰다. 유입부하 검토결과, BOD는 유입 설계기준 대비 140.7%, $COD_{Mn}$는 120.32%, SS는 106.3%로 조사되었으며, T-N은 135.5%, T-P는 173.3%로 설계기준보다 높게 유입되고 있었다. 처리시설의 연간 운영비를 조사한 결과, 슬러지 처리비(27.7%)와 약품비(26.0%)가 높은 비중을 차지하였으며, 슬러지 처리비는 해양투기 금지로 더욱 상승할 것으로 판단된다. 수산물 가공폐수 처리단가는 1톤당 3,858원으로 하수처리비용(142.6원/ton)에 비해 27배 이상으로 높게 조사되었는데, 이는 고농도의 유기물과 영양염류를 포함하고 있기 때문으로 판단된다.

Combined Effects of High Pressure and Heat on Shear Value and Histological Characteristics of Bovine Skeletal Muscle

  • Rusman, H.;Gerelt, B.;Yamamoto, S.;Nishiumi, T.;Suzuki, A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제20권6호
    • /
    • pp.994-1001
    • /
    • 2007
  • Changes in shear force value, transverse sections, myofibrils and intramuscular connective tissue of bovine skeletal muscle exposed to the combination of high-pressure up to 400 MPa and heat (30 and $60^{\circ}C$) were studied. The shear force value decreased by pressure-heat treatment up to 200 MPa at 30 and $60^{\circ}C$, and then slightly increased over 200 MPa at $30^{\circ}C$. Shear force values of treated muscles were lower than those of untreated ones. Gaps between muscle fibers in the untreated muscle were a little clear, and then they became very clear in the treated muscles up to 200 MPa at 30 and $60^{\circ}C$. However, the gaps reduced significantly over 200 MPa at $30^{\circ}C$. The remarkable rupture of I-band and loss of M-line materials progressed in the myofibrils with increasing pressure applied. However, degradation and loss of the Z-line in myofibrils observed in the muscle treated at $60^{\circ}C$ was not apparent in the muscle treated at $30^{\circ}C$. The length of the sarcomere initially contracted by pressure-heat treatment of 100 MPa at $30^{\circ}C$ seemed to have recovered with increase of the pressure up to 400 MPa. In the muscle treated at $60^{\circ}C$, the length of sarcomere gradually decreased with increase of the pressure up to 400 MPa. In the treated muscles, changes in the honeycomb-like structure of endomysium were observed and accelerated with increase of the pressure. A wavy appearance clearly observed at the inside surface of endomysium in the untreated muscles gradually decreased in the treated muscles with increase of the pressure. Tearing of the membrane was observed in the muscles treated over 150 MPa at $30^{\circ}C$, as observed in the sample pressurized at 100 MPa at $60^{\circ}C$. The roughening, disruption and fraying of the membrane were observed over 200 MPa at $60^{\circ}C$. From the results obtained, the combination of high-pressure and heat treatments seems to be effective to tenderize tough meat. The shear force value may have some relationship with deformation of intramuscular connective tissue and myofibrils.

건설 현장 내 비점오염원 처리 시설의 제거 특성 평가 (Characteristics Evaluation of Non Point Source Treatment Facilities in Construction Site)

  • 최영화;정설화;김창용;김효상;오지현
    • 한국지반환경공학회 논문집
    • /
    • 제10권3호
    • /
    • pp.53-62
    • /
    • 2009
  • 본 연구는 건설 현장에서 발생하는 비점오염원 발생 특성에 대해서 파악하고, 이에 대한 관리 기술들을 적용하여, 각 시설별 효과에 대해 평가하고자 하였다. 건설 현장의 공사 단계별로 비점오염원의 발생 특성을 보면, 공사 초반 즉, 토양 피복 상태가 교란되어 있는 경우, 강우 시 부유물질 부하량이 높게 나타나며, 강우 강도에 대한 민감도가 공사 후반에 비해 높은 것으로 확인되었다. 건설 현장에서 가설 형식으로 적용할 수 있는 기술로는 부유물질을 제어할 수 있는 Check dam, Silt fence 공법과 강우 시 토사 유실을 원천적으로 제어하는 Geotextile공법을 적용한 결과, Geotextile이 다른 공법에 비해 비점오염원 유출량 제어에 효과적인 것으로 확인 되었다. Check dam과 Silt fence는 공극에 의한 부유물질 제거 기능이 일부 있으나, 전반적으로 일시적 저류에 의한 침강효과로 오염물질을 제거 하는 특징이 있다. 이러한 가설 형식 처리 시설의 경우, 처리 효율이 낮아 주변 민원 또는 수계 오염을 유발할 수 있으며, 이에 부가적으로 가압식 여과 방법을 통해 연계 처리한 결과 만족할 만한 방류 수질을 기대할 수 있었다. 또한, 이러한 여과 방법은 여과 속도와 유입 부하량에 따라 처리 가능한 부하량이 결정되며, 효과적 운전을 위해서는 전처리가 반드시 필요하다.

  • PDF

TP304계 고질소 스테인레스강의 단조특성과 냉간압연 모사 (Forged Product Characteristic and Cold Rolling Simulation for High-Nitrogen Stainless Steel (HNS))

  • 이명열;이종욱;김병구;김영득;신종호
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.310-313
    • /
    • 2009
  • 오스테나이트계 고질소 스테인레스강 4 가지 후보강종인 HNS C1, C2, C3, C4에 대해 질소함량, 가압조건 따른 단조재와 온도 및 동일한 가압조건에서 Ni 합금원소 첨가유무에 따른 용체화 처리재(HNS C1, C3)의 물성평가와 실제 냉연 공정의 pass schedule 검증을 위한 모사실험을 통해 다음과 같이 요약 하였다. 1) 가압증가에 따른 질소함량의 증가로 강도 및 경도가 동시 상승하며, 결정립의 미세화 및 기계적 쌍정 발생이 많았다. 동일한 가압조건에서 Ni 첨가된 HNS C3가 Ni 미첨가한 HNS C1 보다 강도-연성 조합평가에서 열/냉간 가공성 등의 특성이 우수하였다. 2) 고질소강 스테인레스강의 적정한 용체화 처리온도 범위는 상용화된 AIS1304와 유사한 $1050^{\circ}C{\sim}1100^{\circ}C$이며, 용체화처리 후냉각방법의 변경(수냉과 공냉)에 따른 경도의 편차는 없었다. 냉연 pass schedule 검증을 위한 모사실험에서 초기 압연의 최적조건은 roll 속도 5mpm, pass당 압연율 $15{\sim}17%$였다.

  • PDF

초고압처리 및 결착제 첨가가 재구성 돈육의 품질특성에 미치는 효과 (Effects of High Pressure and Binding Agents on the Quality Characteristics of Restructured Pork)

  • 최예철;정경훈;천지연;최미정;홍근표
    • 한국축산식품학회지
    • /
    • 제33권5호
    • /
    • pp.664-671
    • /
    • 2013
  • 본 연구에서는 식육의 재구성에 첨가되는 식염의 함량을 줄인 저염 재구성육 제품을 제조하기 위하여 다양한 결착제의 활용, GdL 첨가 및 초고압처리 수준에 따른 재구성돈육의 품질 특성을 조사하였다. 본 연구에서 첨가된 0.5% GdL 수준은 제품의 pH를 유의적으로 감소시키며, GdL 자체 혹은 초고압처리에 의한 식육단백질의 젤 형성에 기인하여 효과적으로 pH 저하에 따른 보수력 감소를 억제할 수 있었다. 또한 첨가된 결착제에 의한 부가적인 보수력 및 조직감 향상을 얻을 수 있었다. 따라서 본 연구결과 초고압 처리 및 GdL을 조합 사용함으로써 식육 재구성에 요구되는 식염의 함량을 0.5%까지 저감시킬 수 있었으며, 다양한 식물성 단백질을 활용한 식육 재구성이 가능할 것으로 기대되었다.

소금과 Glucono-$\delta$-Lactone의 첨가 및 초고압 처리가 재구성 돈육의 이화학적 특성에 미치는 영향 (Effects of Salt, Glucono-$\delta$-Lactone and High Pressure Treatment on Physico-Chemical Properties of Restructured Pork)

  • 홍근표;박성희;김지연;고세희;민상기
    • 육가공
    • /
    • 통권34호겨울호
    • /
    • pp.26-39
    • /
    • 2007
  • 본 실험은 소금 및 GdL의 첨가가 세척 및 가압 처리된 재구성육의 이화학적 특성에 미치는 효과를 규명하고자 실시되었다. 소금 및 GdL의 첨가는 재구성육의 결착강도를 현저하게 증가시켰고, 저염농도 또는 소금이 무첨가 되어도 소량의 GdL의 첨가에 의한 결착강도의 향상을 기대할 수 있었다. 그러나 GdL의 첨가는 색도를 가열처리와 유사하게 변색시켰고, 이러한 변색은 GdL의 증가와 더불어 현저하였다. 그러나 이들 단점은 세척이나 기타 첨가물에 의하여 향상시킬 수 있으리라 판단되었다. 따라서 본 실험의 결과에 의하면 소량의 소금 및 GdL의 조합을 통하여 바람직한 결착강도 및 변색 저하를 기대할 수 있었고, 첨가된 인산염과 carrageenan에 의한 보수력의 향상 효과를 얻을 수 있었다.

  • PDF