• Title/Summary/Keyword: pressure measurements

Search Result 1,751, Processing Time 0.026 seconds

Comparison of Sound Pressure for Detecting Incorrect Sonar Measurements (잘못된 초음파 센서 데이터를 여과하기 위한 음압 비교법)

  • Lee, Kyoung-Min;Chung, Wan-Kyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.3
    • /
    • pp.273-279
    • /
    • 2009
  • In this paper, we address the problem of detecting incorrect sonar measurements. We use ideas from the inconsistency of information among sonar measurements together with the sound pressure of the wave from the sonar sensor to develop a new method, called the comparison of the sound pressure (CSP), to detect incorrect sonar readings. The inconsistency of information in cells can be a clue that indicates candidates for incorrect measurements, and the sound pressure of the wave from the sonar sensor determines incorrect readings among the candidates. From various experiments, the proposed method is confirmed that it is better than existing method at deciding the state of sonar measurements.

Estimation of Degree of Consolidation in Soft Ground Using Field Measurements and Rheology Model (현장 계측치와 유변학적 모형을 이용한 연약지반의 압밀도 추정)

  • Lee, Dal-Won;Yoon, Hyun-Jung
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.47 no.2
    • /
    • pp.87-96
    • /
    • 2005
  • In this research, an attempt is made to derive the practical estimation of the degree of consolidation in soft clay from field measurements under embankments. For the practical estimation of pore water pressure in soft clay, the elasto-viscous rheological model was proposed, with a transform of parameters and a field geotechnical measurements in southern Korea. By using the rheological properties of soft clays and the dissipation of excess pore water pressure behaviour during step loading, a degree of consolidation or pore water pressure estimation in the future can be performed, and are shown to be generally close to the field measurements of pore water pressure. Finally, a pore water pressure behaviour in soft clay can be explained through measured data in field and the excess pore water pressure data can also be used to estimate settlement.

Characteristics of Synchronous and Asynchronous modes of fluctuations in Francis turbine draft tube during load variation

  • Goyal, Rahul;Cervantes, Michel J.;Gandhi, Bhupendra K.
    • International Journal of Fluid Machinery and Systems
    • /
    • v.10 no.2
    • /
    • pp.164-175
    • /
    • 2017
  • Francis turbines are often operated over a wide load range due to high flexibility in electricity demand and penetration of other renewable energies. This has raised significant concerns about the existing designing criteria. Hydraulic turbines are not designed to withstand large dynamic pressure loadings on the stationary and rotating parts during such conditions. Previous investigations on transient operating conditions of turbine were mainly focused on the pressure fluctuations due to the rotor-stator interaction. This study characterizes the synchronous and asynchronous pressure and velocity fluctuations due to rotor-stator interaction and rotating vortex rope during load variation, i.e. best efficiency point to part load and vice versa. The measurements were performed on the Francis-99 test case. The repeatability of the measurements was estimated by providing similar movement to guide vanes twenty times for both load rejection and load acceptance operations. Synchronized two dimensional particle image velocimetry and pressure measurements were performed to investigate the dominant frequencies of fluctuations, vortex rope formation, and modes (rotating and plunging) of the rotating vortex rope. The time of appearance and disappearance of rotating and plunging modes of vortex rope was investigated simultaneously in the pressure and velocity data. The asynchronous mode was observed to dominate over the synchronous mode in both velocity and pressure measurements.

Development of an Automatic Blood Pressure Device based on Korotkoff Sounds

  • Li, Xiong;Im, Jae Joong
    • International journal of advanced smart convergence
    • /
    • v.8 no.2
    • /
    • pp.227-236
    • /
    • 2019
  • In this study, we develop a Korotkoff sound based automatic blood pressure measurement device including sensor, hardware, and analysis algorithm. PVDF-based sensor pattern was developed to function as a vibration sensor to detect of Korotkoff sounds, and the film's output was connected to an impedance-matching circuit. An algorithm for determining starting and ending points of the Korotkoff sounds was established, and clinical data from subjects were acquired and analyzed to find the relationship between the values obtained by the auscultatory method and from the developed device. The results from 86 out of 90 systolic measurements and 84 out of 90 diastolic measurements indicate that the developed device pass the validation criteria of the international protocol. Correlation coefficients for the values obtained by the auscultatory method and from the developed device were 0.982 and 0.980 for systolic and diastolic blood pressure, respectively. Blood pressure measurements based on Korotkoff sound signals obtained by using the developed PVDF film-based sensor module are accurate and highly correlated with measurements obtained by the traditional auscultatory method.

An Experimental Study on Shallow Water Effect in Slamming (천수에서의 슬래밍 현상에 대한 실험적 연구)

  • Kang, Hyo-Dong;Oh, Seung-Hoon;Kwon, Sun-Hong
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.60-66
    • /
    • 2009
  • This study presents an experimental investigation of the shallow water impact of a box type structure. The analysis was done based on the video images captured by a high speed camera, the flow field obtained by PIV (Particle Image Velocimetry), and pressure measurements in the divided region. The video images showed quite good agreement with the description given by Korobkin. The PIV measurements of the velocity field provided a clear view of the flow pattern for all three stages. The pressure was measured at the bottom of the tank with strain gauge type pressure gauges. The pressure measurements showed the characteristics of divided regions.

On Employing Nonparametric Bootstrap Technique in Oscillometric Blood Pressure Measurement for Confidence Interval Estimation

  • Lee, Yong-Kook;Lee, Im-Bong;Chang, Joon-Hyuk;Lee, Soo-Jeong
    • Journal of Korea Multimedia Society
    • /
    • v.17 no.2
    • /
    • pp.200-207
    • /
    • 2014
  • Blood pressure (BP) is an important vital signal for determining the health of an individual subject. Although estimation of mean arterial blood pressure is possible using oscillometric blood pressure techniques, there are no established techniques in the literature for obtaining confidence interval (CI) for systolic blood pressure (SBP) and diastolic blood pressure (DBP) estimates obtained from such BP measurements. This paper proposes a nonparametric bootstrap technique to obtain CI with a small number of the BP measurements. The proposed algorithm uses pseudo measurements employing nonparametric bootstrap technique to derive the pseudo maximum amplitudes (PMA) and the pseudo envelopes (PE). The SBP and DBP are then derived using the new relationships between PMA and PE and the CIs for such estimates. Application of the proposed method on an experimental dataset of 85 patients with five sets of measurements for each patient has yielded a smaller Cl than the conventional student t-method.

The Comparison on the Compression Measurement Value of Medical Compression Stockings (수입 의료용 압박스타킹의 압력 측정치 비교)

  • Do, Wol-Hee;Kim, Nam-Soon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.37 no.8
    • /
    • pp.1060-1074
    • /
    • 2013
  • This study measured and analyzed pressure at each measurement part of imported compression stockings sold in Korea to provide basic information to establish a pressure standard and grade ranking. This study used 40 medical compression stockings imported from 6 countries. Pressure measurements were taken at 11 points: front side and back side of ankle, end-point of the gastrocnemius muscle, front, inner side, back, and outer side of calf, back side of below knew girth, inner side, and outer side of mid-thigh girth, and inner side of thigh girth. AMI 3037-10 and AMI 3037-2 were used for measurements taken inside an environmental chamber at a temperature of $21^{\circ}C$ and a relative humidity (RH) of 65%. For the measurements, 11 air pack sensors were attached to a wooden model leg (Hohenstein) and three measurements were taken at each measurement point in three minutes. The average of these measurements was used for analysis. The findings of this study were as follows. As for the front side of the ankle, of the 40 products, 14 products (6 USA, 2 Swiss, 3 Italian, and 2 Taiwanese) were within the pressure range indicated on the product label; however, no German products fell within the pressure range. A total of 8 products (5 USA, 1 Swiss, 1 Italian, and 1 German) were gradient compression type; however, no Japanese or Taiwanese product were of this type. The majority of products had the highest pressure at the end-point of the gastrocnemius muscle. Only 3 products, 1 USA (Jobst Opaque 30-40mmHg), 1 Swiss (Sigvaris Cotton 34-46mmHg) and 1 Italian (Jobstocking 25-32mmHg), had measurements that met the indicated standard pressure, were a gradient compression type, and met the overall standard for compression stockings.

The Change of Blood Pressure according to the Number of Measurements and the Number of Visits (측정 횟수 및 방문 횟수에 따른 혈압 변화)

  • Park, Ji-Eun;Lee, Min-Hee;Ryu, Yeon-Hee;Liu, Yan;Jung, Hee-Jung;Hong, Sang-Hoon;Lee, Seung-Deok;Kim, Nam-Kwen;Choi, Sun-Mi
    • Korean Journal of Oriental Medicine
    • /
    • v.18 no.3
    • /
    • pp.111-118
    • /
    • 2012
  • Objective : The aim of this study was to investigate the number of measurements and visits for blood pressure measurement. We also analyzed the change of blood pressure based on the measurement method and measurement interval. Methods : Data of three clinical trials evaluating the effect of acupuncture, moxibustion, and qigong for pre and mild essential hypertension were used. Blood pressure was measured 3 times each visit with 1 or 5 minutes interval, and it was checked until $3^{rd}$ visit. Two trials used sphygmomanometer and another one trial used automatic device for blood pressure measurement. Results : The mean difference between $1^{st}$ and $2^{nd}$, and $2^{nd}$ and $3^{rd}$ measurement were significant in systolic (p<0.001) and diastolic blood pressure (p<0.001). However, in automated measurement or measuring with 1 minute interval, the difference between $2^{nd}$ and $3^{rd}$ was not significant. The mean of $1^{st}$ and $2^{nd}$ measurements was also significantly different from the mean of all three measurements in both systolic (p<0.001) and diastolic blood pressure (p<0.001). While the difference between each visit was not significant in diastolic blood pressure, the systolic blood pressure difference was significant between $1^{st}$ and $2^{nd}$ visit in automated and manual measurement. Conclusion : The mean of two measurements and three measurements were significantly different. The change of blood pressure was different according to the method and interval of blood pressure measurement.

Estimation of Noise Level near Cross Bow Fan by Measurements of Static Pressure. (정압을 이용한 직교류팬 주변의 소음 예측)

  • Kim, Jae-Won;Cho, Yong;Jung, Yoon-Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.1156-1161
    • /
    • 2001
  • A significant trial has been performed for estimation of noise level of a cross flow fan for air conditioning system. In general, measurements of noise level of machinery require rigorous equipment involving an anechoic chamber with precision gauges. The apparatus is expensive to utilize and is not easy to construct. In this work, we adopt static pressure sensing from an ordinary pressure transducer for prediction of noise level of a rotating fan. The present procedure is finding sound pressure from the static pressure by manipulating Light-Curle equation depicts noisy energy in terms of pressure on surfaces of noise generators. Sound power level near core unit of the fan is evaluated with the present methodology in a normal laboratory room without any sound absorbers. The method is easy and shows good prediction results compared with precise measurements by using microphones.

  • PDF

A Comparision of a Direct and Three Indirect Methods of Measuring Blood Pressure (직접혈압측정치와 3가지 간접혈압측정치의 비교)

  • Lee Myung-Hwa;Park Hyo-Kyung;Shon Soo-Kyung
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.5 no.1
    • /
    • pp.95-106
    • /
    • 1998
  • The purpose of this study was to compare direct and three indirect blood pressure measurements in adults and to compare among three indirect blood pressure measurements in adults. One direct(intraarterial) and three indirect(using a mecury sphygmomanometer, a aneroid type sphygmomanometer and an automatic auscultatory device) methods of blood pressure measurement were compared in adult patients who had an arterial line. The subjects for this study consisted of 29 patients in K medical center, B medical center, B hospital and M hospital in Pusan. The data was collected from October 1, 1992 to June 30, 1993. The collected data was analysed with the SPSS program, frequency, percentage, mean, S.D., t-test, ANOVA. The results of this study were as follows : 1) There was a significant difference in the systolic BP when using the direct and three indirect measurements(P<0.05). 2) There was no overall significant difference in the diastolic BP when using the direct and three indirect measurements. 3) There was no significant difference in the SBP and DBP among the three indirect measurements.

  • PDF