Development of an Automatic Blood Pressure Device based on Korotkoff Sounds  

Li, Xiong (Dept of Electronic Engineering, Chonbuk National University)
Im, Jae Joong (Dept of Electronic Engineering, Chonbuk National University)
Publication Information
International journal of advanced smart convergence / v.8, no.2, 2019 , pp. 227-236 More about this Journal
Abstract
In this study, we develop a Korotkoff sound based automatic blood pressure measurement device including sensor, hardware, and analysis algorithm. PVDF-based sensor pattern was developed to function as a vibration sensor to detect of Korotkoff sounds, and the film's output was connected to an impedance-matching circuit. An algorithm for determining starting and ending points of the Korotkoff sounds was established, and clinical data from subjects were acquired and analyzed to find the relationship between the values obtained by the auscultatory method and from the developed device. The results from 86 out of 90 systolic measurements and 84 out of 90 diastolic measurements indicate that the developed device pass the validation criteria of the international protocol. Correlation coefficients for the values obtained by the auscultatory method and from the developed device were 0.982 and 0.980 for systolic and diastolic blood pressure, respectively. Blood pressure measurements based on Korotkoff sound signals obtained by using the developed PVDF film-based sensor module are accurate and highly correlated with measurements obtained by the traditional auscultatory method.
Keywords
Blood pressure measurement; Korotkoff sounds; PVDF film; Auscultatorty method;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Stamier J., Neaton J. D., Wentworth, D. N. "Blood pressure (systolic and diastolic) and risk fatal coronary heart disease," Hypertension, 3(5 Suppl):I2-12, 1989.
2 Williams J.S., Brown S.M., Conlin P.R. "Blood-pressure measurement," N Engl J Med 2009; 360:e6. DOI: 10.12691/ajhr-1-1-6.   DOI
3 Guyenet P. G. "The sympathetic control of blood pressure," Nature review neuroscience 7(5): 335-346, 2006. DOI: 10.1038/nrn1902   DOI
4 Poulter N. R., Prabhakaran D., Caulfield M. "Hypertension," Lancet. 386(9995):801-12, 2015. DOI: 10.1016/S0140-6736(14)61468-9   DOI
5 Lackland D. T., Weber M. A. "Global burden of cardiovascular disase and stroke: hypertension at the core," The Canadian journal of cardiology. 31(5): 569-71. DOI: 10.1016/j.cjca.2015.01.009   DOI
6 O'Brien E, Parati G, Stergiou G et al. "European Society of Hypertension position paper on ambulatory blood pressure monitoring," J Hypertens, 31: 1731-1768, 2013. DOI: 10.1097/HJH.0b013e328363e964.   DOI
7 Mancia G, Fagard R, Narkiewicz K et al. "2013 ESH/ESC guidelines for the management of arterial hypertension," Eur Heart J, 34: 2159-2219, 2013. DOI: 10.1097/01.hjh.0000431740.32696.cc.   DOI
8 Bevan A.T., Honour A.J., Stott F.H., "Direct arterial pressure recording in unrestricted man," Br Heart J 31(3):387-388, 1969.
9 Pickering T. G., Hall H. E., Appel L. J., et al. "Recommendation for blood pressure measurement in humans and experimental animals part 1: blood pressure measurement in humans: a statement of professionals from the subcommittee of professional and public education of the American heart association council on high blood pressure research," Hypertension. 45(1):142-161, 2005. DOI: 10.1161/01.CIR.0000154900.76284.F6   DOI
10 O'Brien E, Fitzgerald D. "The history of blood pressure measurement," J Hum Hypertens 8(2):73-84, 1994.
11 Myers M.G, Godwin M, Dawes M, Kiss A, Tobe S.W., Kaczorowski J. "The conventional versus automated measurement of blood pressure in the office (CAMBO) trial: masked hypertension sub-study," J Hypertens. 30:1937-1941, 2012. DOI: 10.1097/HJH.0b013e328356abd3   DOI
12 Armstrong R. S. "Nurses' knowledge of error in blood pressure measurement technique," International journal of nursing practice. 8(3):118-126, 2002. DOI: 10.1046/j.1440-172X.2002.00348.x   DOI
13 Drzewiecki G. M., Melbin J., Noordergraaf A. "The korotkoff sound," Ann Biome Eng. 17: 325-359, 1989. DOI: 10.1007/BF02368055   DOI
14 John A, Tobias G, al, "Characterization of Korotkoff Sounds Using Joint and Frequency Analysis". IOP- PM -25 -107, 2004. DOI: 10.1088/0967-3334/25/1/010   DOI
15 Geddes L. A., Voelz M., Combs C., Reiner D., Babbs C. F. "Charactrerization of the oscillometric method for measuring indirect blood pressure" Annals of biomedical engineering, 10(6):271-280, 1982.   DOI
16 Zheng D, Amoore JN, Mieke S, Smith FE, King ST, Murray A. "Automated Blood Pressure Measurement: Reasons for Measurement Variability Uncovered," Computers in Cardiology, 36:21-24, 2009.
17 Van Montfrans G. A. "Oscillometric blood pressure measurement: progress and problems," Blood press monit. 6(6):287-90, 2001.   DOI
18 Raamat R., Talts J., Jagomagi K., Kivastik J. "Errors of oscillometric blood pressure measurement as predicted by simulation," Blood press monit, 16(5): 238-245, 2011. DOI:10.1097/MBP.0b013e32834af752   DOI
19 Li X., Gayathri P., Im J. J. "A study for the development of K-sound based automatic blood pressure device using PVDF film," 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2016. DOI: 10.1109/EMBC.2016.7590688
20 E. O'Brein, et al. "Working Group on Blood Pressure Monitoring of the European society of hypertension International Protocol for validation of blood pressure measuring devices in adults," Blood Pressure Monitoring, vol. 7: 3-17, 2002.   DOI
21 O'Brien E, Atkins N, Stergiou G, Karpettas N, Parati G, Asmar R, et al. "European Society of Hypertension International Protocol revision 2010 for the validation of blood pressure measuring devices in adults," Blood Press Monit, 15:23-38, 2010. DOI: 10.1097/MBP.0b013e3283360e98.   DOI