• Title/Summary/Keyword: preset

Search Result 206, Processing Time 0.024 seconds

The Quantitative Assessment of Renal Function and Size by Differences of Acquisition Counts in $^{99m}Tc$-DMSA Renal Scan ($^{99m}Tc$-DMSA 신장검사에서 획득 계수의 차이에 따른 기능 및 형태 평가)

  • Shim, Dong-Oh;Kim, Ho-Sung;Chung, Eun-Mi
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.117-121
    • /
    • 2010
  • Purpose: In nuclear medicine study, there are two methods, preset count method and preset time method, to acquire static images. We usually use preset count method for static image in $^{99m}Tc$-DMSA renal scan, but occasionally use preset time method. In case of using preset count method, we always acquire same counts but it causes a difference of scan time. In case of using preset time method, it takes same scan time to acquire images but it causes different counts. Therefore, the purpose of this study is to investigate any differences of function and formal information in both kidney by acquisition counts Materials and Methods: From January 11, 2010 to March 31, 2010, we analyzed the 30 patients (M: 11, W: 19). who were examined by $^{99m}Tc$-DMSA scan and have one side of functioning kidney relatively between 40~60%. And the patients who have cold and hot region in image were analyzed but we did not accept images of patients when it was hard to divide kidney into cortex. There was no division between subjects and age of subjects is $14.83{\pm}22.07$ old. We used the BrightView gamma camera from PHILIPS. To analyze function and formal of kidney, we used JET stream release 3.0 version from PHILIPS. Using SPSS 12.0 program, we compared descriptive statistics and paired T-test. Images were acquired sequentially in the same parameters, but there are three methods which different from acquisition time and scan time, 100 kcounts, 300 kcounts and 7 minutes method (exceed 300 kcounts). To assess function and formal information of kidney, we measured renal relative function, geometric mean and size of kidney and analyzed each difference. Results: In case of renal relative function in both kidney, 100 kcounts method was $50.52{\pm}3.64%$. 300 kcounts method was $50.38{\pm}3.66%$ and 7 minutes method was $49.91{\pm}3.40%$ and there were no statistical significant differences between each method. In case of geometric mean, 100 kcounts method was $50.08{\pm}3.25%$. 300 kcounts method was $49.89{\pm}3.40%$ and 7 minutes method was $49.91{\pm}3.24%$. And also, there were no statistical significant differences. When comparing size of kidney, 100 kcounts method was $8.23{\pm}1.96$ cm. 300 kcounts method was $8.12{\pm}1.90$ cm and 7 minutes method was $8.35{\pm}1.97$ cm. In case of right kidney, 100 kcounts method was $7.91{\pm}1.88$ cm. 300 kcounts method was $8.12{\pm}1.90$ cm and 7 minutes method was $8.25{\pm}1.96$ cm. From those values, we recognized that there were significant differences each method (p<0.05). Conclusion: From results of this study, there were no statistical differences in renal relative function and geometric mean by acquisition counts. However, in shape of kidney, the more acquisition counts are increasing, the more size of kidney is getting big. And there were statistical significant differences. Therefore, to perform reliable quantitative result, preset count method is more desirable than preset time method. Especially, in case of a follow-up test, if we use preset time method, it will cause differences of formal results in kidney due to acquisition counts each time we examine patients.

  • PDF

Aerodynamic performance enhancement of cycloidal rotor according to blade pivot point movement and preset angle adjustment

  • Hwang, In-Seong;Kim, Seung-Jo
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.9 no.2
    • /
    • pp.58-63
    • /
    • 2008
  • This paper describes aerodynamic performance enhancement of cycloidal rotor according to the blade pivot point movement and the blade preset angle adjustment. Cycloidal blade system which consists of several blades rotating about an axis in parallel direction and changing its pitch angle periodically, is a propulsion mechanism of a new concept vertical take off and landing aircraft, cyclocopter. Based on the designed geometry of cyclocopter, numerical analysis was carried out by a general purpose commercial CFD program, STAR-CD. According to tills analysis, the efficiency of cycloidal rotor could be improved more than 15% by the introduced methods.

Switched-Capacitor Variable Gain Amplifier with Operational Amplifier Preset Technique

  • Cho, Young-Kyun;Jeon, Young-Deuk;Kwon, Jong-Kee
    • ETRI Journal
    • /
    • v.31 no.2
    • /
    • pp.234-236
    • /
    • 2009
  • We present a novel operational amplifier preset technique for a switched-capacitor circuit to reduce the acquisition time by improving the slewing. The acquisition time of a variable gain amplifier (VGA) using the proposed technique is reduced by 30% compared with a conventional one; therefore, the power consumption of the VGA is decreased. For additional power reduction, a programmable capacitor array scheme is used in the VGA. In the 0.13 ${\mu}m$ CMOS process, the VGA, which consists of three-stages, occupies 0.33 $mm^2$ and dissipates 19.2 mW at 60 MHz with a supply voltage of 1.2 V. The gain range is 36.03 dB, which is controlled by a 10-bit control word with a gain error of ${\pm}0.68$ LSB.

  • PDF

File Format Design for Interactive Music Service

  • Jang, In-Seon;Seo, Jeong-Il;Kang, Kyeong-Ok
    • ETRI Journal
    • /
    • v.33 no.1
    • /
    • pp.128-131
    • /
    • 2011
  • This letter describes a file format designed for interactive music service where users are able to recompose music based on their own preferences. The proposed design utilizes the flexible features of the ISO base media file format (ISO/IEC 14496-12, ISO-BMFF). The techniques offered in the proposed file format enable compact storage and efficient preset management, allowing users to recompose music with ease and convenience. Additionally, an implementation scheme for an interactive music player is shown along with its results.

Initial Frequency Preset Technique for Fast Locking Fractional-N PLL Synthesizers

  • Sohn, Jihoon;Shin, Hyunchol
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.4
    • /
    • pp.534-542
    • /
    • 2017
  • This paper presents a fast locking technique for a fractional-N PLL frequency synthesizer. The technique directly measures $K_{VCO}$ on a chip, computes the VCO's target tuning voltage for a given target frequency, and directly sets the loop filter voltage to the target voltage before the PLL begins the normal closed-loop locking process. The closed-loop lock time is significantly minimized because the initial frequency of the VCO are put very close to the desired final target value. The proposed technique is realized and designed for a 4.3-5.3 GHz fractional-N synthesizer in 65 nm CMOS and successfully verified through extensive simulations. The lock time is less than $12.8{\mu}s$ over the entire tuning range. Simulation verifications demonstrate that the proposed method is very effective in reducing the synthesizer lock time.

DYNAMIC SET-UP CONTROL OF TANDEM COLD MILL (연속압연기에서 OFF GAUGE 저감을 위한 DYNAMIC SET-UP 제어기술)

  • 노호섭;최병조;조뇌하;이재훈;김익준;진철제;박기영
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.08a
    • /
    • pp.126-131
    • /
    • 1999
  • In order to reduce the length of off-gauge at FGC(Flying gauge change) point, We adopted dynamic set up in No. 4 cold rolling mill. The conventional set-up of FGC(Flying gauge change) was calculated on the basis of preset values in the process control computer, so the difference between actual strip thickness and preset thickness cause long off-gauge. The dynamic SET-UP control was calculated on the basis of actual strip thickness of FGC(Flying gauge change) point from X-ray gauge of mill entry and No.i stand. We applied dynamic SET-UP control in September last year. Compare to the previous result, the length of off-gauge is reduced by about 36%.

  • PDF

A Study for Resource Allocation Method with Workload Consideration in Container based VDI (컨테이너 기반 VDI 시스템에서 워크로드 패턴 기반 자원 할당 방법 연구)

  • Baek, Hyeon-Ji;Kim, Yong-Hyun;Huh, Eui-Nam
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2017.11a
    • /
    • pp.24-26
    • /
    • 2017
  • 클라우드 컴퓨팅 시장과 클라우드 기반 가상화 기술이 꾸준한 성장과 함께 지속적으로 인기를 얻으며 다양한 분야에서 사용되고 있다. 본 논문에서는 가상화 기술 중 하나인 데스크톱 가상화의 실행 속도 개선을 위해 컨테이너 기반 VDI 시스템을 제시하였고 사용자 워크로드 기반 자원 할당된 컨테이너를 제공하기 위해 사용자 워크로드 패턴에 따른 Preset 자원 결정 과정을 제시한다. 또한, Preset 자원이 할당 된 컨테이너를 생성과 사용자 워크로드 맞춤형 컨테이너를 제공하기 위한 기반으로 VDI 컨테이너의 자원 사용량 데이터를 K-means 알고리즘을 사용하여 군집 분석을 수행하였다.

Characteristics Analysis of SRM Drive System for Hydraulic Pump (유압펌프용 SRM 구동 시스템의 특성해석)

  • Lee, Ju-Hyun;Kim, Bong-Chul;Kim, Tae-Hyung;Ahn, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.83-86
    • /
    • 2005
  • This paper proposed a hydraulic pump system which uses a variable SR drive and constant capacity pump. The base and maximum speed, torque are determined from displacement capacity of the pump and maximum pressure. The drive system is set to have a minimum power consumption having hydraulic preset pressure, which is operated within a maximum capacity and maximum preset pressure. This is achieved by controlling motor speed and power with feedback signal of pressure of the hydraulic pump. A 2.2kw, 12/8-pole SR motor and DSP based digital controller are designed and prototype drive system is manufactured. The proposed variable speed SR drive system is simulated and tested with experimental set-up. The test results show that the system has some good features such as high efficiency and high response characteristics.

  • PDF

Investigation of the Causes of Uncooled Region Induced at Top End in Wire Rolling Process (선재압연에서의 소재선단 미수냉부 발생원인 규명)

  • Son, Boong-Ho;Yoo, Jea-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2516-2518
    • /
    • 2000
  • In order to reduce the trimming loss for water cooling zone next to finishing block mill in wire rolling, the operational data related to the crop length control of uncooled region was acquired and analyzed. The time deviation of water cooling spray nozzles and the immoderate preset length of uncooled wire rod result in the excessive trimming loss. Therefore, the preset length of uncooled wire rod at each cooling zone are established. The test results of #3 wire rolling mill turned out to be good enough to be expected to increase the ratio of products about 0.15% and establish operational standards of cooling zone.

  • PDF

Effect of Curing Conditions on the Strength of Fly-Ash Based Geopolymer (양생조건이 플라이애쉬 기반 지오폴리머 강도에 미치는 영향)

  • Cho, Young-Keun;Moon, Gyu-Don;La, Jung-Min;Jung, Sang-Hwa
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.449-456
    • /
    • 2014
  • Material properties of geopolymer, whose the reaction is very complicated, have been influenced by chemical compositions and particle size distributions of fly ash, concentrations and types of alkali-activators and curing conditions such as temperatures and time. In this research, experiments with several variables such as curing temperatures, preset prior to the high temperature curing and high temperatures have been conducted in order to evaluate to investigate effects on the compressive strengths of geopolymer caused by curing condition. Experiment results were evaluated with compressive strengths and micro-structures such as SEM and MIP of geopolymer pastes. As a result, as higher curing temperature or longer preset time were applied to the pastes, higher compressive strengths were observed. However, compressive strengths of geopolymer pastes declined due to increases in macropores (>50 nm) under high temperatures elapsed after 24 hours. In this sense, it can be considered that strengths and microstructures of geopolymers depends on curing temperature and time.