• Title/Summary/Keyword: preparation technique

Search Result 798, Processing Time 0.039 seconds

Transmission Electron Microscope Specimen Preparation of Si-Based Anode Materials for Li-Ion Battery by Using Focused Ion Beam and Ultramicrotome

  • Chae, Jeong Eun;Yang, Jun Mo;Kim, Sung Soo;Park, Ju Cheol
    • Applied Microscopy
    • /
    • v.48 no.2
    • /
    • pp.49-53
    • /
    • 2018
  • A successful transmission electron microscope (TEM) analysis is closely related to the preparation of the TEM specimen and should be followed by the suitable TEM specimen preparation depending on the purpose of analysis and the subject materials. In the case of the Si-based anode material, lithium atoms of formed Li silicide were removed due to ion beam and electron beam during TEM specimen preparation and TEM observation. To overcome the problem, we proposed a new technique to make a TEM specimen without the ion beam damage. In this study, two types of test specimens from the Si-based anode material of Li-ion battery were prepared by respectively adopting the only focused ion beam (FIB) method and the new FIB-ultramicrotome method. TEM analyses of two samples were conducted to compare the Ga ion damage of the test specimen.

The experimental study of the effect of the hybrid instrumentation method with ProTaper and ProFile on the change of root canal area and distance from the canal to the root surface after canal shaping. (ProTaper와 ProFile을 사용한 Hybrid instrumentation method의 근관 형성 전, 후 근관 단면적과 근관벽에서 치근외면까지 최단거리의 변화에 미치는 영향에 대한 실험적 연구)

  • Kim, Seok-Min;Park, Dong-Sung
    • The Journal of the Korean dental association
    • /
    • v.45 no.6 s.457
    • /
    • pp.362-369
    • /
    • 2007
  • The aim of this study was to investigate the effect of the hybrid instrumentation method with ProTaper and ProFile on the change of root canal area and distance from the canal to the root surface after canal shaping. The mesial canals of twenty extracted mandibular first molars having $10-20^{\circ}\Delta$ curvature were scanned using X-ray microcomputed tomography (XMCT)-scanner before root canals were instrumented. They were divided into four groups (n=10 canals ter group). In Group 1, root canals were instrumented by the step-back technique with stainless steel K-Flexofile after coronal flaring. The remainders were instrumented by the crown-down technique with, ProTaper system (Group 2), ProFile (Group 3) or ProTaper (Group 4). All canals were prepared up to size 25 at the end-point of preparation and scanned again. Pre- and post-operative cross-sectional images of 1, 3, 5, and 7 mm from the apical foramen were compared. For each level, change of cross-sectional canal are and distance to the nearest external root surface was calculated using Adobe Photoshop 6.0 and image software program. In the change of cross-sectional area, Group 4 was less than Group 2 at 3 mm and 5 mm level (p<0.05). In the difference of the distance from the canal to the root surface after canal shaping, Group 4 was least among the other groups at 7 mm level (p<0.05). According to the results, the methods using ProFile or K file only and the hybrid instrumentation technique using ProTaper and ProFile are more appropriate methods of canal preparation than ProTaper system for narrow of curved canals.

  • PDF

Aluminum Oxide Nano-Rings Synthesized by Electrospinning Techniques

  • Jo, Jun-Mo;Park, Ju-Yeon;Go, Seong-Wi;Kim, Don;Gang, Yong-Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.102-102
    • /
    • 2010
  • One or two-dimensional nanostructures such as nanowires or nanomats have been widely uses as building blocks for nanoscale electronic devices. Nanofiber is one of sub-category of nano structures, it is easy to make nano-sized fiber by electrospinning technique. Nanofiber has large surface area as compared with their volume, it could be widely applied to many areas easily. Electrospinning technique is easy to control their structures and morphology safely and cost-effectively. We made nano-rings as a model of one dimensional nanostructures by electrospinning technique. To our knowledge, there were no reports on the preparation and investigation of alumina nano-rings by electrospinning technique. In this study, aluminum oxide nano-rings were produced after electospinning and calcination. The synthesized aluminum oxide nano-rings were characterized by scanning electron microscopy (SEM) to identify the morphology and the diameter of the ring, X-ray diffraction (XRD) to verify the crystallinity of the aluminum oxide, and X-ray photoelectron spectroscopy (XPS) for investigation of the chemical nature of the synthesized nano-rings.

  • PDF

Detection of Damages in Concrete Structures Using Non-Contact Air-Coupled Sensing Methods

  • Shin, Sung-Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.3
    • /
    • pp.282-289
    • /
    • 2010
  • Most nondestructive testing techniques require good contact between the sensor and tested concrete surface to obtain reliable data. But the surface preparation is often very time and labor consuming due to the rough surface or limited access of concrete structures. One approach to speed up the data collection process is to eliminate the need for physical contact between the sensor and tested structure. Non-contact air-coupled sensing technique can be a good solution to this problem. An obvious advantage of the non-contact air-coupled sensing technique is which can greatly speed up the data collection in field and thus the damage detection process can be completed very rapidly. In this article, recent developments in non-contact air-coupled sensing technique for rapid detection of damages in concrete structures are summarized to evoke interest, discussion and further developments on this technique to a NDT research community in Korea. It is worth noting that the works in this article have been published in the types of thesis, proceedings, and journals. All published sources are cited in the text and listed in reference.

Low Dilution Glass Bead Digestion Technique for the Trace Element Analysis of Rock Samples (저희석 유리구 용해법에 의한 암석시료 미량원소 분석법)

  • Park, Chan-Soo;Shin, Hyung-Seon;Oh, Hae-Young;Moon, Jong-Hwa;Cheong, Chang-Sik
    • The Journal of the Petrological Society of Korea
    • /
    • v.20 no.3
    • /
    • pp.161-172
    • /
    • 2011
  • Open beaker digestion method is routinely used as the sample preparation technique for trace element determination of rock samples by inductively coupled plasma mass spectrometry, With this method, however, dissolution of Zr and Hf is not always guaranteed especially when the samples contain refractory minerals. In this study, glass bead digestion technique was compared with conventional open beaker digestion technique for the sample preparation of three USGS rock standards such as AGV-2, BHVO-2, and G-3. Thirty trace elements including rare earth elements were analysed by ICP-MS and ICP-AES. There were no clear differences in analytical results for the AGV-2 and BHVO-2 standards between the two techniques, but Zr, Hf, Y, and middle- to heavy- rare earth element concentrations of the G-3 standard prepared by open beaker digestion technique were significantly lower than the recommended values. This can be attributed to the presence of refractory mineral zircon. On the contrary, all the analytical results of the G-3 standard prepared by glass bead digestion technique were in good agreement with the recommended values, indicating complete dissolution of zircon. The analytical results show that the volatile elements such as Pb and Zn were not lost during the preparation of glass bead. Low dilution glass bead digestion technique described here will be very helpful to enhance precision and accuracy of trace element analysis for geological samples containing refractory minerals.

Evaluation of Young's Modulus of a Cantilever Beam by TA-ESPI (TA-ESPI에 의한 외팔보의 탄성계수 측정)

  • Lee H.S.;Kim K.S.;Kang K.S.;Jung H.C.;Yang S.P.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1115-1119
    • /
    • 2005
  • The paper proposes the elastic modulus evaluation technique of a cantilever beam by vibration analysis based on time-average electronic speckle pattern interferometry (TA-ESPI) with non-contact and nondestructive and Euler-Bernoulli equation. General approaches for the measurement of elastic modulus of thin film are Nano indentation test, Bulge test and Micro-tensile test and so on. They each have strength and weakness in the preparation of test specimen and the analysis of experimental result. ESPI has been developed as a common measurement method for vibration mode visualization and surface displacement. Whole-field vibration mode shape (surface displacement distribution) at a resonance frequency can be visualized by ESPI. And the maximum surface displacement distribution from ESPI is a clue to find the resonance frequency at each vibration mode shape. And the elastic modules of test material can be easily estimated from the measured resonance frequency and Euler-Bernoulli equation. The TA-ESPI vibration analysis technique is able to give the elastic modulus of materials through the simple processing of preparation and analysis.

  • PDF