• 제목/요약/키워드: precipitator

검색결과 234건 처리시간 0.033초

운전조건에 따른 전기집진장치의 특성관계 연구 (A Study on the Characteristics for Electrostatic Precipitator by Operating Conditions)

  • 하상안;김일배
    • 한국환경보건학회지
    • /
    • 제24권2호
    • /
    • pp.145-150
    • /
    • 1998
  • This study was carried out to investigate the loss amount of collection at the different of precipitatation time, high voltage and gas speed. This work has focused on the dependence of the collection efficiency in the collector zone with gas speed and high voltage. This advanced Model is developed by research of the different parameter as the conventionnal modem of study. In order to investigate collection efficiency of electrostatic precipitator, the loss amount of knocking was measured with Monitek-Treubung and the particle size was analyzed by He-Ne laser diffraction spectroscopy.

  • PDF

2단식 전기집진기 내에서 블록의 영향에 따른 입자의 집진효율 (Collection Efficiency of Particles with Effect of Blocks in the Two-Stage Electrostatic Precipitator)

  • 박성호;박청연
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2000년도 춘계학술대회 논문집
    • /
    • pp.217-218
    • /
    • 2000
  • 유해입자 배출 저감을 위한 대기오염 제어장치로는 필터(filter), 관성장치(inertialdevices), 침전조(settling), 스크루버(scrubber), 전기집진기(ElectroStatic Precipitator, ESP)등이 있다. 이 중, 정전기력을 이용한 전기집진기는 대전과정과 집진과정이 동일한 곳에서 이루어지는 1단식(one-stage)과 독립적으로 이루어지는 2단식(two-stage)으로 분류되며, 2단식의 경우, 대전부(charging section)와 집진부(collecting section)는 몇 개의 대전셀(charging cell)과 집진셀(collecting cell)들로 구성되어져 있다. (중략)

  • PDF

설계인자 변화에 따른 소형 전기집진장치의 최적효율 예측 (Predicted Optimum Efficiency due to Changes in the Design Parameters of the Small Electrostatic Precipitator)

  • 서정민;이병인;정문섭;박정호;임우택;박출재;최금찬
    • 한국환경과학회지
    • /
    • 제22권9호
    • /
    • pp.1187-1197
    • /
    • 2013
  • The result of a small electrostatic precipitator which is in order to decrease indoor air pollution for optimal efficiency was shown as follows. Although the closer distance between the discharge electrode and dust collecting electrode shows the better throughput efficiency by forming strong electrostatic Field, it does not have profound impact in case of optimal dust collecting area. G.P(gas passage) which is the distance from dust collecting electrode to dust collecting electrode is a crucial factor to decide dust collecting efficiency. The narrower distance of G.P shows the better throughput efficiency whereas it decreases when the distance is too narrow since sparks ensue by increasing the capacity of electrostatic charging system 5 mm regards as optimal efficiency in this experiment. Although the higher voltage shows the higher dust collecting efficiency overall, the experiment was not able to keep performing since the sparks which decrease dust collecting efficiency ensue over 40 kV. The efficient and safe voltage state is considered 3.6 kV in this experiment. The most crucial factor for dust collecting efficiency of an electrostatic precipitator which is in order to decrease indoor air pollution is applied voltage. In addition, optimal raw gas flow rate(2.4 m/sec) is more important factor than the excessive increase of dust collecting area.

수열합성법으로 제조된 지르코니아의 나노분말 특성 (Characteristics of Zirconia Nanoparticles with Hydrothermal Synthesis Process)

  • 조치욱;태원필;이학성
    • 공업화학
    • /
    • 제25권6호
    • /
    • pp.564-569
    • /
    • 2014
  • 지르코니아 나노분말을 수열합성법으로 제조하였으며, 반응온도, 반응시간, 침전제의 종류 및 농도, 전구체의 종류를 실험 변수로 하였고, 각각의 제조된 분말을 X-선 회절(XRD)과 주사전자현미경(FE-SEM)을 통해 입자크기 및 결정상을 측정하였다. 침전제의 농도 증가에 따라 지르코니아 입자크기가 증가하였으며, 입자의 결정화도도 높아졌고, KOH 보다 NaOH 침전제를 사용하였을 경우, 입자 성장 속도가 증가하였다. 이는 입자의 크기 컨트롤에 있어 NaOH를 사용하는 경우보다 KOH를 사용하는 것이 더 효과적이었다. 4 h의 수열반응시간에서는 4 h의 수열반응시간에서는 비정질의 지르코니아 입자가 발견되었지만, 8 h 이상 합성 시, 단사정상의 지르코니아 입자가 생성됨을 확인하였고, 반응시간이 길어짐에 따라 지르코니아 입자의 폭이 소폭으로 줄어들고, 길이는 소폭 늘어남을 확인하였다. 동일한 합성 조건에서 전구체로서 zirconium (IV) acetate, zirconium nitrate, zirconium chloride 중에서 zirconium chloride를 사용하여 합성하였을 경우, 입자의 크기가 가장 작게 형성되었다.

도로터널용 전기집진시스템 개발 (Development of Road Tunnel Ventilation System with Electrostatic Precipitator)

  • 김종률;원종웅
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.80-83
    • /
    • 2008
  • As SOC (Social Overhead Capital) has been expanded, the highway road construction has been accelerated and city road system has been more complicated. So, long road tunnels have been increased and traffic flow rate also has been raised. Accordingly, the exhausting gas of vehicle cars seriously deteriorates the tunnel inside air quality and driving view. In order to improve tunnel inside air quality, we may need to introduce a compulsory ventilation system as well as natural ventilation mechanism. The natural ventilation mechanism is enough for short tunnels, meanwhile longer tunnels require a specific compulsory ventilation facility. Many foreign countries already have been devoting on development of effective tunnel ventilation system and especially, some European nations and Japan have already applied their developed tunnel ventilation system for longer road tunnels. More recently, as the quality of life improved, our concerns about safety of driving and better driving environment have been increased. In order to obtain clearer and longer driving view, we are more interested in EP tunnel ventilation system in order to remove floating contaminants and automobile exhaust gas. Evan though it's been a long time since many European countries and Japan applied more economical and environment-friendly tunnel ventilation system with their self-developed Electrostatic Precipitator, we are still dependant on imported system from foreign nations. Therefore, we need to develop our unique technical know-how for optimum design tools through validity investigation and continuous possibility examination, eventually in order to localize the tunnel ventilation system technology. In this project, we will manufacture test-run products to examine the performance of system in order to develop main parts of tunnel ventilation system such as electrostatic precipitator, high voltage power generator, water treatment system, etc.

  • PDF

도시철도 지하터널용 전기집진기 개발을 위한 집진극 형상에 대한 기초연구 (A Study on Collecting Electrode Design for Developing Electrostatic Precipitator(ESP) of Urban Railway Underground Tunnels)

  • 구태용;김용민;홍정희;황정호
    • 한국입자에어로졸학회지
    • /
    • 제9권2호
    • /
    • pp.79-87
    • /
    • 2013
  • In this study, the characteristics of turbulent flow and collection efficiency for an one-stage electrostatic precipitator(ESP) with slit type collecting electrode for urban railway underground tunnels were obtained using computational fluid dynamics(CFD) commercial code FLUENT 6.3 and lab-scale experiments. The electrostatic precipitator was operated under high gas velocity(3~12m/s). Five different designs of collecting electrode, flat plate-type and a slit-type of 3mm, 5mm, 7mm and 10mm slit width and four various gas velocity(3, 6, 9, and 12m/s) were used and applied. A standard k-${\varepsilon}$ model in CFD commercial code FLUENT 6.3 was used for flow simulation. The flow simulation results showed that the turbulent intensity of flat plate-type was higher than slit-type under all gas velocity conditions and also the turbulent intensity of flat plate-type was increased continuously, but in case of slit-type was maintained at constant range. And, the turbulent intensity was decreased according to increasing of slit width. The experimental results showed that the collection efficiency of slit-type was higher than flat plate-type under all gas velocity conditions. And, over 6m/s gas velocity condition, the collection efficiency of 5mm and 7mm was highest, when compared to 3mm and 10mm.

정전 고속 미스트 엘리미네이터의 포집 효율 특성 (Particle removal characteristics of high-velocity electrostatic mist eliminator)

  • 김진선;김학준;한방우;우창규;김용진;이상린;문상철
    • 한국입자에어로졸학회지
    • /
    • 제14권4호
    • /
    • pp.121-133
    • /
    • 2018
  • In this study, we developed a flat-plate type wet electrostatic precipitator that generates stable corona discharge compared to wire type discharge electrode. In order to compare the particle removal efficiency according to the shape of the discharge electrode such as the variation of the horizontal and vertical distance between spiked edges, and the variation of the height of discharge pin support were tested. As a result, when the horizontal distance between spiked edges was increased up to 36 mm, the vertical distance between spiked edges was increased up to 54 mm, and the height of the discharge pin support was increased up to 76 mm, the removal efficiency of PM10 was maintained at approximate 60.0%. Furthermore, the removal efficiency of particles over $5{\mu}m$ was about 80% or more. When the flow rate was 4 m/s, the gap between collection plates was 60 mm, and -14 kV was applied to the discharge electrode. The particle removal efficiency of the flat-plate type electrostatic precipitator was maintained when the horizontal and vertical distance between spiked edges, and the height of the discharge pin support was below a certain level. Those variables may be the important design factors for the shape of the discharge electrode. Therefore, when designing the electrostatic precipitator with multiple channels, the horizontal and vertical distance between spiked edges, and the height of discharge pin support must be selected in consideration of the weight of the discharge electrode and the processing cost.

1단 전기 집진기에서 2차 유동이 집진 효율에 미치는 영향 (Effect of Secondary Flows on the Particle Collection Efficiency in Single Stage Electrostatic Precipitator)

  • 이재복;배귀남;황정호
    • 대한기계학회논문집B
    • /
    • 제24권2호
    • /
    • pp.251-259
    • /
    • 2000
  • The ionic wind formed in a nonuniform electric field has been recognized to have a significant effect on particle collection in an electrostatic precipitator(ESP). Under normal operating conditions the effect of ionic wind is not pronounced. However, as the flow velocity becomes smaller, the ionic wind becomes pronounced and induces secondary flow, which has a significant influence on the flow field and the particle collecting efficiency. In this paper, experiments for investigating the effect of secondary flow on collection efficiencies were carried out by changing the flow velocities in 0.2-0.7m/s and the applied voltages in 9-11kV/cm. The particle size distributions and concentrations are measured by DMA and CNC. To analyze the experimental results, numerical analysis of electric filed in ESP was carried out. It shows that particle collection is influenced by two independent dimensionless numbers, $Re_{ehd}\;and\;Re_{flow}$ not by $N_{ehd}$ alone. When $Re_{flow}$, decreases for constant $Re_{ehd}$, the secondary flow prohibits the particle collection. But when $Re_{ehd}$ increases for constant $Re_{flow}$, it enhances the particle collection by driving the particles into the collection region.

Electrostatic Precipitability of the Coal Fly-Ash by the Pilot Scale Test

  • Ahn, Kook-Chan;Kim, Bong-Hwan;Jang, Yang-Sik
    • Journal of Mechanical Science and Technology
    • /
    • 제15권5호
    • /
    • pp.602-612
    • /
    • 2001
  • The equation of the particle collection efficiency proposed by Deutsch has been modified through the various experiments to correct the errors caused by the assumptions made for the equation. In order to get an modified Deutsch equation that can be applied to real conditions, a pilot scale electrostatic precipitator is used. The effects of operational variables on the particle collection efficiency are evaluated. Particle resistivity, gas temperature, moisture contents in gas, gas velocity and particle concentration are used as the operational variables. Two different types of coal fly-ash obtained from the fluidized bed combustor and the pulverized coal combustor are used as test particulate to evaluate the effect of the physiochemical and electrical characteristics of the particle on the particle collection efficiency. The experimental results are fitted with the modified Deutsch equation made by Matts-Ohnfeldt and the extended Deutsch equation made by E. C. Potter to evaluate the effect of the particle characteristics and the operation conditions on the particle collection efficiency of the electrostatic precipitator.

  • PDF