• 제목/요약/키워드: precast concrete panel

검색결과 125건 처리시간 0.02초

청구 스플라이스 슬리브 시스템 개발에 관한 연구 (A Study on the Development of Chonggu Splice-Sleeve System)

  • 곽철승;이용재;이동우;김병균;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 가을 학술발표회 논문집
    • /
    • pp.508-513
    • /
    • 1996
  • The purpose of this paper, having chosen the connection method, filled by High-strength mortar, in conncetion of PC member, is to study the mechanical behaviour and practical usage of the method. The paper estimates the connection ability of Reinforced-bar, that is, Sleeve considering the effect of Reinforced-bar's dimeter. Sleeve's length and diameter in the structural behaviour of mortar-filled connection, therefore the behaviour of Splice-Sleeve exists in concrete practically. This paper discusses the effect of the concrete in Splice-Sleeve. Also, to estimate structural behaviour in a practical wall panel, the upper and bottom wall panels are produced and the behaviour of Splice-Sleeve is discussed. And then Vertical Tie Bar being designed by using Precast method, this paper presents the various application and the practicable method using Splice-Sleeve.

  • PDF

터널 풍도슬라브에 사용된 내화패널의 적용성에 관한 실험연구 (An Experimental Study on the Application of Fireproof Panel in Tunnel Duct Slab)

  • 최우진
    • 한국재난정보학회 논문집
    • /
    • 제19권2호
    • /
    • pp.262-269
    • /
    • 2023
  • 연구목적: 터널에서 발생되는 화재로 인하여 구조물의 피해를 보호하기 위해 적용되는 PSC 슬래브에 부착된 내화패널의 성능을 평가할 목적으로 내화실험을 수행하였다. 연구방법: 내화실험은 RWS 화재 이력곡선 화재시간-온도곡선을 적용하였으며, 한국건설기술연구원(KICT)의 가열로를 이용하여 내화 성능을 평가하였다. 연구결과:국제터널학회(2004)에서 제시하는 기준으로 내화성능 실험을 실시한 결과, 내화패널과 콘크리트의 접촉면에서의 최대온도는 콘크리트에 손상을 주는 한계온도(380℃) 이하였으며, 접촉면과 25mm 이격된 지점에서의 최대온도는 철근에 손상을 주는 한계온도(250℃) 이하로 측정되었다. 실험결과로부터, 내화패널이 30mm두께로 부착된 PSC 슬래브 시험체는 내화성능을 가진 것으로 평가되었다. 결론: 터널이나 지하차도에서의 화재발생시 내화패널을 부착하는 보강방법은 화재로부터 구조물을 보호할 수 있으며 향후, 내화패널이 부착된 슬래브의 정적 성능시험을 수행하고, Pull-off test와 피로실험을 실시하여 내화패널의 부착성능을 확인하는 것이 필요하다.

저분체 기반 고유동 콘크리트의 Steel Concrete Panel Mock-up 부재 충전 성능 평가 (Evaluation of Filling Performance of Steel Concrete Panel (SCP) Mock-up Member with Low-binder based High-fluidity Concrete)

  • 박기준;박정준;김성욱
    • 대한토목학회논문집
    • /
    • 제39권4호
    • /
    • pp.477-483
    • /
    • 2019
  • 최근 원자력발전소 및 LNG 저장탱크 등 특수구조물의 공사 기간과 비용 절감을 목적으로 PSC 구조물 대신 프리캐스트 형식의 SCP 모듈의 사용이 증가하고 있다. SCP 모듈 내부는 강재와 콘크리트의 일체 거동을 위해 스터드로 연결되어 있어 고유동 콘크리트의 사용이 요구된다. 고유동 콘크리트는 일반적으로 많은 단위결합재량를 가지기 때문에 수화열 및 수축의 증대, 비경제적인 강도 발현 문제 등이 발생한다. 따라서 본 연구에서는 저분체 기반 고유동 콘크리트 최적 배합을 선정하기 위해 재료적 특성에 따른 고유동 콘크리트의 유동성 및 철근의 간극 통과성능을 검토하고, 펌프카를 활용하여 펌핑 전후에 따른 콘크리트의 물성을 검토하며, 최종적으로 강재와 강재 사이를 콘크리트로 채우는 SCP Mock-up 부재에 대하여 고유동 콘크리트의 충전 성능을 평가하였다.

균열방지 슬리브가 매설된 패널식 옹벽 (Concrete-Panel Retaining Wall anti-crack sleeve inserted)

  • 장성호;정지승
    • 문화기술의 융합
    • /
    • 제5권3호
    • /
    • pp.345-349
    • /
    • 2019
  • 우리나라는 산지가 70% 이상으로 도로, 철도, 산업단지 조성 등의 기반시설 구축시 원지반 일부를 깍아 부지를 형성하는 이른바 깍기 비탈면이 널리 쓰이고 있다. 최근에는 환경 훼손에 대한 규제가 더욱 엄격해져 대규모 깍기 비탈면을 지양하고 최소한의 용지사용으로 목적구조물을 건설하기 위하여 다양한 방법의 공법들이 개발되어 적용되고 있으며, 그 중 활발하게 적용되는 공법이 패널식 옹벽 공법이다. 패널식 옹벽은 지보재 보강을 통한 원지반의 전단강도 증가와 그 지보재 전면에 프리캐스트 옹벽을 체결하여 벽체를 형성시킴으로써 수평토압에 저항하는 공법이다. 지보재는 쏘일네일링, 어스볼트, 그라운드앵커 등이 사용되고 있으며, 그 중 그라운드앵커는 강선에 미리 인장하중을 도입하는 보다 적극적인 보강형태로 전면판인 패널에 큰 집중하중이 작용하게 된다. 이러한 집중하중은 콘크리트 패널에 균열을 발생시키고 옹벽 자체의 내구성을 저해시키는 요인으로 본 연구에서는 이러한 기존 패널식 옹벽의 단점을 보완하기 위하여 패널 정착부에 강관 슬리브 및 보강재를 매입함으로써 균열을 방지하고, 패널 단부에 요철 모양의 전단키를 적용하여 기존 그라우트앵커가 가지는 개별거동에 대한 취약점을 보완하여 안정성을 향상시켰으며, 옹벽 전면 콘크리트 노출 및 정착부 돌출에 의한 경관성 저하문제를 자연석 문양 연출과 정착부를 돌출시키지 않는 단면구성으로 해결하였다. 패널에 사용된 균열방지 슬리브 및 보강재의 효과를 검증하기 위하여 실내시험 및 3차원 수치해석을 수행한 결과, 강관슬리브 및 보강재의 사용으로 패널의 전반적인 강도 증가와 균열억제 효과가 입증되었다.

PC 전단벽 건식접합부에 관한 실험연구 (An Experimental Study on Dry-Connection for Precast Concrete Shear Walls)

  • 홍성걸;임우영
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.21-24
    • /
    • 2005
  • In this study, new methods of PC panel connection using 'ㄷ'type steel connection is proposed for highly seismic zone. A study was carry out to investigate the connection behavior subjected to cyclic inelastic loading. Three planar type and two T type PC wall will be tested. The variables will be examined were the shear reinforcement existence of top and bottom walls. The specimens will be tested only reverse cyclic loading in accordance with a prescribed displacement history. To transfer the shear strength shear key set up between top and bottom wall. Failure mode, behavior, ductility and energy dissipation capacity of the specimens constructed by new connections wll be compared with those of monolithic walls and Han's(Han, Jun Hee, Seoul National University) model.

  • PDF

마이크로파에 의한 PC접합모르타르의 조기강도추정에 관한 연구 (A Study on Early Strength Estimation of Precast Concrete joint Mortar with Microwave)

  • 원준연;박일용;백민수;이종균;안형준;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.217-222
    • /
    • 2000
  • A large Pc structure building is system that consisted of bearing wall and slab joint. It has general structure stability from unity thar each members tied at joint. The strength of mortar that packing in joint among panels is important to internal force in entire building system. Do, if we could get early strength estimation with microwave. It would bring good construction planning, reduce construction time, and judge building stability and so on. The purpose of this study is to develop early estimation method for making better quality control and constructing good PC panel structure. The results of this study were as follows :1) With sealed molds, reduced moisture volatilization to more than 60% and enlarged 30% accelerated compressive strength than before one. 2) To get more accelerated strength, we should control maximum temperature difference to $30^{\circ}C$ downward 3)Interrelation with 7-day and 28-day strength were 0.831,0.902, and it is above than before one

  • PDF

박판 프리캐스트 콘크리트 영구거푸집 시스템 연구 (II) (A Study of Permanent Form System by Thin Precast Concrete Panel (II))

  • 남기룡;정문영;정문열;서치호;김윤일
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.749-754
    • /
    • 1997
  • Nowadays domestic building market has undergone several changes. Labor costs are too high and materials are in short supply. These raised building costs and therefore lowered productivity. At this point it is the best way to reduce manual labor and find alternative materials that can improve productivity. In the building process form work take the most part of it. So many formwork systems were developed to reduce the construction period and labor cost. But their technical improvements just limited to adjust form shape-the role of form is not changed. This research developed a new formwork systems that can function to unify or minimze the unit process with cast-in-place type permanent form. In former study (reported in '97 spring seminar), we did the assembling test with column and beam clamps. Furthermore, In this paper, we examined the total systems of form erections and evaluated the structural performances.

  • PDF

프리캐스트 ECC 벽판으로 보강된 비내진 상세를 갖는 철근콘크리트 골조의 내진성능 (Seismic Performance of Non-ductile Reinforced Concrete Frames with Precast ECC Wall Panels)

  • 김지현;조성필;서수연;윤현도
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권6호
    • /
    • pp.105-112
    • /
    • 2019
  • 본 논문은 비내진 상세를 갖는 철근콘크리트 골조 및 필로티 건물의 보강방법으로 높은 연성을 갖는 ECC를 적용한 PC 벽판을 내진 보강요소로 사용하고자 하였다. PC 벽판의 형상비 및 설치 위치를 변수로 RC 골조에 대한 반복가력실험을 실시하여 내진성능을 평가하였다. 실험결과 PC 벽판을 보강함에 따라 기존 RC 골조의 내력 증진, 강도저하 방지, 강성증진 및 에너지 소산능력 향상에 효과적인 것으로 나타났다. 실험결과를 근거로 비내진 상세를 갖는 골조의 강도 증진을 위하여 ECC PC 벽판을 골조의 중앙에 설치하고 연성증진을 위하여 세장한 벽판을 골조의 양측면에서 설치할 것을 제안한다.

현장 배근이 LB-DECK 패널의 구조거동에 미치는 영향 (A Study on the Structural Behavior of LB-DECK Panel Considering Rebar-Arrangement in Site)

  • 노병철;조규대
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권3호
    • /
    • pp.167-174
    • /
    • 2008
  • 본 연구는 최근 교량에 많이 이용되고 있는 프리캐스트 바닥판(LB-DECK) 패널과 후타설 현장콘크리트 슬래브의 합성거동 여부 및 내부에 매입된 하면 주철근의 합성 후 구조적 거동을 분석한 것이다. 이를 위하여 현장배근 주철근의 철근량 및 배근방법에 따라 LB-DECK 패널의 정적거동 실험을 하여 현장타설 콘크리트 패널(FCP)과 비교 분석하였으며, 반복하중에 대한 평가를 위하여 피로실험을 하였다. 실험 결과, LB-DECK 패널 주철근량의 50%를 LB-DECK 패널 내부에 추가 배근하였을 경우 가장 우수한 강성을 나타내었으며, LB-DECK 패널이 FCP에 비해 평균 52.1%의 강성 증가 효과가 있음을 알 수 있었다. 또한 LB-DECK 패널에 대한 피로 실험 결과 200만회 반복하중에서도 충분한 건전도를 유지함을 알 수 있었다.

Strength and behaviour of bamboo reinforced concrete wall panels under two way in-plane action

  • Ganesan, N.;Indira, P.V.;Himasree, P.R.
    • Advances in concrete construction
    • /
    • 제6권1호
    • /
    • pp.1-13
    • /
    • 2018
  • An experimental investigation has been carried out on the use of an environmentally sustainable material, bamboo, in the construction of precast concrete structural wall panels. The strength and behaviour of three prototype bamboo reinforced concrete wall panel specimens under two-way in-plane action was studied. The specimens with varying aspect ratio and thinness ratio were tested to fail under a uniformly distributed in-plane load applied at an eccentricity of t/6. The aspect ratio of the specimens considered includes 1.667, 1.818 and 2 and the thinness ratio includes 12.5, 13.75 and 15. The influence of aspect ratio and thinness ratio of bamboo reinforced concrete wall panels, on its strength and behaviour was discussed. Varnished and sand blasted bamboo splints of 20 mm width and thickness varying from 8 to 15 mm were used as reinforcement in concrete. Based on the study, an empirical equation was developed considering the geometrical parameters of bamboo reinforced concrete wall panels for predicting its ultimate strength under two way in-plane action.