• Title/Summary/Keyword: pre-filter system

Search Result 168, Processing Time 0.021 seconds

Removal Characteristics of Rainwater Including Non-point Pollutants Using Pre-filter of Wasted-tire and Non-woven Fabric (폐타이어와 부직포를 이용한 프리필터에 의한 비점오염원 포함 우수 처리 특성)

  • Yoo, Kyuseon;Han, Hakyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.655-659
    • /
    • 2005
  • Pre-filter system that was consisted of wasted-tire, non-woven fabrics, and sponge was developed as a primary treatment process prior to rainwater reservation or a pre-treatment process of rainwater reuse system for reclamation. By using this system, SS concentration, TOC, COD, and turbidity could decreased by 86.7%, 62.6%, 69.1% and 66.5%, respectively. From the results of particle size distribution of treated water, the particles over than $30{\mu}m$ of diameter were completely removed by pre-filter system. But 90% of particles less than $20{\mu}m$ of diameter were passed through pre-filter. Optimal depth of wasted-tire and non-woven fabrics were 15cm and 2.4cm, respectively. Pre-filter system was considered as an effective alternative for pre-treatment of rainwater including non-point pollutants and it could be also applied for the treatment of combined sewer overflow (CSO).

Indoor Mobile Localization System and Stabilization of Localization Performance using Pre-filtering

  • Ko, Sang-Il;Choi, Jong-Suk;Kim, Byoung-Hoon
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.2
    • /
    • pp.204-213
    • /
    • 2008
  • In this paper, we present the practical application of an Unscented Kalman Filter (UKF) for an Indoor Mobile Localization System using ultrasonic sensors. It is true that many kinds of localization techniques have been researched for several years in order to contribute to the realization of a ubiquitous system; particularly, such a ubiquitous system needs a high degree of accuracy to be practical and efficient. Unfortunately, a number of localization systems for indoor space do not have sufficient accuracy to establish any special task such as precise position control of a moving target even though they require comparatively high developmental cost. Therefore, we developed an Indoor Mobile Localization System having high localization performance; specifically, the Unscented Kalman Filter is applied for improving the localization accuracy. In addition, we also present the additive filter named 'Pre-filtering' to compensate the performance of the estimation algorithm. Pre-filtering has been developed to overcome negative effects from unexpected external noise so that localization through the Unscented Kalman Filter has come to be stable. Moreover, we tried to demonstrate the performance comparison of the Unscented Kalman Filter and another estimation algorithm, such as the Unscented Particle Filter (UPF), through simulation for our system.

Numerical Analysis of Axial-Flow Cyclone Separator for Subway Station HVAC System Pre-Filter

  • Kim, Myung-Joon;Kim, Ho-Joong;Kwon, Soon-Bark;Kim, Se-Young;Kim, Jin-Kwan;Shin, Chang-Hun;Bae, Sung-Joon;Hwang, Sun-Ho;Kim, Tae-Sung
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.17 no.3
    • /
    • pp.94-99
    • /
    • 2009
  • In the Korean subway station, three types of pre-filters, which include auto filter, electrostatic precipitator (ESP) and auto cleaning demister, are widely used. However, these devices have some problems such as the difficulty of maintenance and high operating cost. In this study, axial-flow cyclone separator was employed as a pre-filter inside a heating, ventilation, and air conditioning (HVAC) system. 3-dimensional computational fluid dynamics (CFD) analysis was performed on a single unit axial-flow cyclone and coupled unit axial-flow cyclone. Calculated and measured pressure drop of the designed axial-flow cyclone were found be comparable to other types of pre-filters and the observed cut-off diameter was less than 10 micron. Considering lower operating and maintenance cost, axial-flow cyclone was proved to be a better solution as a pre-filter.

Removal of Virus in Home Drinking Water Treatment Systems (가정용 정수시스템의 바이러스 제거)

  • 김영진;오남순;정문호
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.4
    • /
    • pp.45-48
    • /
    • 2000
  • Reverse osmosis filtration(RO) system and ultrafiltration(UF) system are principally use for domestic home drinking water treatment systems. The object of this study is to make a comparison between two systems in terms of theirs abilities to remove RNA coilphage QB as an indicator of pathogenic enteroviruses. The virus removal ratio of RO system was 99.999%, which was higher than EPA virus treatment guideline(99.99%). In the course of filtration, removal ratios of sediment filter, pre-carbon filter, reverse osmosis membrane and post-carbon filter were 75.000%, 93.208%, 99.997% and 99.999%, repectively. In case of UF system, virus removal ratio was 99.708%. Removal ratios of sediment filter, pre-carbon filter, post-carbon filter and ultrafiltration membration membrane were 71.038%, 91.530%, 98.283% and 99.708%, respecively, in UF steps. Therefore, RO system is more effective than UF system in virus removal.

  • PDF

Modulation and Pre-equalization Method to minimize time delay in Equalization Digital On-Channel Repeater (등화형 디지털 동일채널 중계기의 시간지연을 최소화하기 위한 변조 및 전치등화 방법)

  • Park Sung-Ik;Kim Heung-Mook;Seo Jae-Hyun;Eum Ho-Min;Lee Yong-Tae;Lee Jae-Young;Lee Soo-In
    • Journal of Broadcast Engineering
    • /
    • v.11 no.2 s.31
    • /
    • pp.229-241
    • /
    • 2006
  • In this paper we propose and analyze a novel modulation and pre-equalization method to minimize signal processing time delay for the Equalization Digital On-Channel Repeater (EDOCR) in ATSC (Advanced Television Systems Committee) terrestrial digital TV system. The proposed modulation method uses Equi-Ripple (ER) filter coefficients instead of conventional Square Root Raised Cosine (SRRC) after coefficients for VSB (Vestigial Side Bands) pulse shaping. And the proposed pre-equalization method calculates pre-equalizer filter coefficients by using baseband signal as reference signal and demodulated repeater output signal, then generates a new VSB pulse shaping filter coefficients by convolutioning ER filter coefficients and pre-equalizer filter coefficients. The newly generated pulse shaping filter does not have minimized time delay by adjusting the number of pre-taps of the filter, but also compensates linear distortions caused by ER filter and mask filter.

Effects of a Pre-Filter and Electrolysis Systems on the Reuse of Brine in the Chinese Cabbage Salting Process

  • Kim, Dong-Ho;Yoo, Jae Yeol;Jang, Keum-Il
    • Preventive Nutrition and Food Science
    • /
    • v.21 no.2
    • /
    • pp.147-154
    • /
    • 2016
  • In this study, the effects of a pre-filter system and electrolysis system on the safe and efficient reuse of brine in the cabbage salting process were investigated. First, sediment filter-electrolyzed brine (SF-EB) was selected as brine for reuse. Then, we evaluated the quality and microbiological properties of SF-EB and Chinese cabbage salted with SF-EB. The salinity (9.4%) and pH (4.63) of SF-EB were similar to those of control brine (CB). SF-EB turbidity was decreased (from 0.112 to 0.062) and SF-EB residual chlorine (15.86 ppm) was higher than CB residual chlorine (0.31 ppm), and bacteria were not detected. Salinity (2.0%), pH (6.21), residual chlorine (0.39 ppm), chromaticity, hardness, and chewiness of cabbage salted with SF-EB were similar to those of cabbage salted with CB. The total bacterial count in cabbage salted with CB was increased as the number of reuses increased (from 6.55 to 8.30 log CFU/g), whereas bacteria in cabbage salted with SF-EB was decreased (from 6.55 to 5.21 log CFU/g). These results show that SF-EB improved the reusability of brine by removing contaminated materials and by sterilization.

On the Adaptive Pre-processing Technique for the Linearization of a Third-Order Volterra System (3차 볼테라 시스템의 선형화를 위한 적웅 선행처리 기법)

  • Kim, Jin-Young;Choi, Bong-Joon;Nam, Sang-Won
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.1289-1291
    • /
    • 1996
  • In this paper, we propose a new adaptive pre-processing technique for the linearization of a weakly nonlinear system which can be modeled by a Volterra series up to third order. To compensate the nonlinear effects of a given system, an update algorithm for the linear filter coefficients of the proposed adaptive pre-processor is introduced, and to compensate the linear distortion of the given system, the linear inverse filter is also utilized. For the performance test of the proposed adaptive pre-processor, computer simulation results obtained by analyzing an ANRSS loudspeaker model are provided.

  • PDF

The Treatment of Animal Wastewater by the Combination of Trickling Filter System and Activated Sludge Process (살수여상 활성오니 연계방법에 의한 축산뇨요수 처리)

  • Ryoo J. W.
    • Journal of Animal Environmental Science
    • /
    • v.10 no.2
    • /
    • pp.81-86
    • /
    • 2004
  • This experiment was conducted to evaluate combination system of wood chip trickling system and activated sludge process. The results obtained are summarized as tallows. The trickling filter system using wood chip was used as a biological pre-treatment system for treating piggery wastewater. At pre-treatment the removal efficiencies were BOD $91\%$ CODmn $65\%$, SS $75\%$ T-N $73\%$, T-P $69\%$. After pre-treatment the removal efficiencies in activated sludge process were BOD $99\%$ CODmn $94.6\%$, SS $97.8\%$ T-N $91.1\%$, T-P $91\%$. This study shows a very stable method with pre-treatment of trickling filter using wood chip. These combined treatment system was very useful for piggery wastewater.

  • PDF

Treatment Study on the Combustion Gas of Medical Waste (의료폐기물 소각가스 처리에 관한 연구)

  • Lee, Sung-Jin;Seo, Man-Chul
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.3
    • /
    • pp.1-8
    • /
    • 2008
  • Currently, medical waste stoker incinerator is widely used in the emission control technology of health-care risk waste and miscellaneous contaminated waste. In the past, wet type control technology was used to remove the major harmful gaseous contaminants of medical waste such as HCl, $NO_x,\;SO_2$, CO, DUST, Dioxin. However, the treatment cost for wastewater was high and it has a disadvantage for frozen system during winter season. Therefore, in order to obtain effective treatment, the dry type control technology was developed and widely used to remove the gaseous contaminants. In this study, pre-coated bag filter using hydrated lime, ($Ca(OH)_2$), was applied to the dry type control system and the optimum dose of hydrated lime was investigated. The treatment results showed that the dust collection rate was approximately 26.7%. Moreover, the HCl removal rate using pre-coated bag filter ($50mg/sm^3\;Ca(OH)_2$) was 13.52%, which was significantly higher than 3.26% obtained from conventional bag filter.

Development of pre-treatment for the injection water into the aquifer storage and recovery(ASR) in Korea: The two-step rapid filter to reduce physical clogging and secure the volume of the injected water (지하저수지(ASR) 유입수 전처리기법 개발: 물리적 폐색 저하 및 수량공급원활을 위한 2 단계 급속여과지)

  • Park, Byeong-Joo;Do, Si-Hyun;Hong, Seong-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.3
    • /
    • pp.337-345
    • /
    • 2015
  • Two step rapid filter system as a pre-treatment for the injected water into aquifer storage and recovery (ASR) in Korea was developed to reduce physical blockage and secure the volume of the injected water. First, single rapid sand filters with three different media sizes (0.4~0.7, 0.7~1.0 and 1.0~1.4 mm) were tested. Only two sizes (0.4~0.7 and 0.7~1.0 mm) satisfied target turbidity, below 1.0 NTU. However, they showed the fast head loss. To prevent the fast head loss and secure the volume of the injected water, a rapid anthracite filter with roughing media size (2.0~3.4 mm) were installed before a single rapid sand filter. As results, both the target turbidity and reduction of head loss were achieved. It was determined that the media size for a rapid sand filter in two step rapid filter system (i.e. a rapid anthracite filter before a rapid sand filter) was 0.7~1.0 mm. In addition, the effects of coagulant doses on the removal of natural organic matter (NOM), which might cause a biological clogging, were preliminarily evaluated, and the values of $UV_{254}$, dissolved organic carbon (DOC) and SUVA were interpreted.