This experiment was conducted to evaluate combination system of wood chip trickling system and activated sludge process. The results obtained are summarized as tallows. The trickling filter system using wood chip was used as a biological pre-treatment system for treating piggery wastewater. At pre-treatment the removal efficiencies were BOD $91\%$ CODmn $65\%$, SS $75\%$ T-N $73\%$, T-P $69\%$. After pre-treatment the removal efficiencies in activated sludge process were BOD $99\%$ CODmn $94.6\%$, SS $97.8\%$ T-N $91.1\%$, T-P $91\%$. This study shows a very stable method with pre-treatment of trickling filter using wood chip. These combined treatment system was very useful for piggery wastewater.

본 연구는 유지관리비가 적게 소요되고 관리가 용이한 에너지절감형 축산뇨오수 처리기술을 개발하기 위하여 목편 살수여상과 활성오니를 정화기술하는 처리기술을 연구하였다. 1. 스크레파 축사의 축산뇨오수 처리를 위한 목편칩 살수여상 활성오니 연계 시스템을 개발하였다. 처리공정은 축산뇨오수 원수$\to$스크린$\to$목편칩 살수여상$\to$활성오니$\to$침전/오존처리 공정으로 처리하였다. 2. 처리결과 축산뇨오수 원수의 BOD 8,620mg/$\iota$ 에서 최종처리수의 BOD는 58mg/$\iota$로 처리되었다. 또한 COD_{Mn},은 원수 4,290mg/$\iota$에서 232mg/$\iota$, SS 2,228mg/$\iota$에서 49.5mg/$\iota$, T-N 4,223mg/$\iota$에서 395mg/$\iota$, T-P 97.4mg/$\iota$에서 8.0mg/$\iota$로 처리되었다. 3. SS는 목편살수여상조에서 $71.1\%$가 제거되어 활성오니 처리 대비 슬러지 발생량이 $70\%$ 절감되었다.