• 제목/요약/키워드: power-type sequence

검색결과 95건 처리시간 0.024초

PEBB Based Bi-directional Rapid Charging System for EV Traction Battery

  • Kang, Taewon;Chae, Beomseok;Suh, Yongsug
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.323-324
    • /
    • 2013
  • This paper presents a simple and cost-effective stand-alone rapid battery charging system of 30kW for electric vehicles. The proposed system mainly consists of active front-end rectifier of neutral point clamped 3-level type and non-isolated bi-directional dc-dc converter of multi-phase interleaved half-bridge topology. The charging system is designed to operate for both lithium-polymer and lithium-ion batteries. The complete charging sequence is made up of three sub-interval operating modes; pre-charge mode, constant-current mode, and constant-voltage mode. The pre-charge mode employs the stair-case shaped current profile to accomplish shorter charging time while maintaining the reliable operation of the battery. The proposed system is specified to reach the full-charge state within less than 16min for the battery capacity of 8kWh by supplying the charging current of 78A. Owing to the simple and compact power conversion scheme, the proposed solution has superior module-friendly mechanical structure which is absolutely required to realize flexible power expansion capability in a very high-current rapid charging system.

  • PDF

Rapid Electric Vehicle Charging System with Enhanced V2G Performance

  • Kang, Taewon;Kim, Changwoo;Suh, Yongsug;Park, Hyeoncheol;Kang, Byungik;Kim, Simon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.201-202
    • /
    • 2012
  • This paper presents a simple and cost-effective stand-alone rapid battery charging system of 30kW for electric vehicles. The proposed system mainly consists of active front-end rectifier of neutral point clamped 3-level type and non-isolated bi-directional dc-dc converter of multi-phase interleaved half-bridge topology. The charging system is designed to operate for both lithium-polymer and lithium-ion batteries. The complete charging sequence is made up of three sub-interval operating modes; pre-charging mode, constant-current mode, and constant-voltage mode. Each mode is operated according to battery states: voltage, current and State of Charging (SOC). The proposed system is able to reach the full-charge state within less than 16min for the battery capacity of 8kWh by supplying the charging current of 67A. The optimal discharging algorithm for Vehicle to the Grid (V2G) operation has been adopted to maintain the discharging current of 1C. Owing to the simple and compact power conversion scheme, the proposed solution has superior module-friendly mechanical structure which is absolutely required to realize flexible power expansion capability in a very high-current rapid charging system. Experiment waveforms confirm the proposed functionality of the charging system.

  • PDF

분산자원 통합 관리를 위한 OpenADR2.0 및 TASE.2 기반 가상발전소 시스템 (Virtual Power Plant System using OpenADR2.0 and TASE.2 for Integrated Management of Distributed Energy Resource)

  • 서종관;이태일;이휘성;박점배
    • 전기전자학회논문지
    • /
    • 제24권1호
    • /
    • pp.311-318
    • /
    • 2020
  • 가상발전소는 개별 분산자원의 통합 관리를 통해 계통운영에 참여를 가능하게 하는 일종의 소프트웨어 발전소이다. 본 논문에서는 단일 발전시스템으로 가상발전소를 운영하기 위하여 국내 전력시스템 통신에 사용되는 TASE.2(Telecontrol Application Service Element) 표준과 분산자원 관리 기술인 OpenADR(Open Automated Demand Response)2.0 표준을 결합하여 상위 전력시스템과 하위 분산자원을 공통정보모델로 구성한 통신 아키텍처를 제시한다. 분산자원의 기본 형태인 ESS를 TASE.2 SBO(Select Before Operate) 디바이스로 구성하고 관련 오브젝트를 OpenADR2.0 리포트 및 이벤트 서비스와 매핑하여 단일 시퀀스 타입으로 설계한다. 시뮬레이션 검증을 통해 두 표준에 준수한 데이터 교환 및 동작을 확인한다.

민감한 전기전자기기의 전압외란에 대한 영향 최소화 연구 (A Research to Minimizing the Effect of Voltage Disturbances on Sensitive Electrical and Electronic Equipment)

  • 윤갑구
    • 기술사
    • /
    • 제19권2호
    • /
    • pp.10-20
    • /
    • 1986
  • 전압외란(voltage disturbances)에 대하여 민감함 전기전자기기가 받는 영향을 최소화하기 위한 방안으로 전력공급자측에서의 대책과 수용가기기에서의 대응책에 대하여 조사연구하였다. 전력공급자에서의 대책으로는 전압강하 시간의 단축에 대하여 검토하였는데, 효과와 경제성으로 보아 실현가능성이 적었다. 수용가기기에서의 대응책으로는 컴퓨터제어(computer control)와 자동화시스템(automated systems) 등에는 무정전 전원장치 또는 노이즈 서프레서(noise suppressor)나 파워콘디쇼너(power conditioners)를 설치하고, 전자개폐기는 지연석방형 전자개폐기를 채용하며, 가변속제어전동기에는 순간전압부하에 대한 대책이 고려된 제어회로를 채용하고, 고압방전등에는 순간재점등장치가 붙은 등기구를 채용하며, 부족전압계전기는 계전기의 정전시감을 연장하는 방안과 순간정전시에는 자동으로 재투입하는 sequence를 구성하는 방법등이 효과적인 대책으로 검토되었다.

  • PDF

팔 흔들기가 정상인의 보행에 미치는 영향 (The Effect of Arm Swing on Gait in Healthy Adults)

  • 정화수;최수희;박선자;오혜진;조화영
    • 디지털융복합연구
    • /
    • 제12권11호
    • /
    • pp.451-459
    • /
    • 2014
  • 본 연구는 정상 성인의 팔 흔들기 종류에 따른 보행 시 운동역학적인 변화를 알아보기 위해서 실시하였다. 정상 성인 대학생 45명을 대상으로 정상 팔 흔들기, 한 팔 흔들기, 두 팔 움직임 없음 보행, 인위적인 팔 흔들기의 4가지 팔 흔들기 종류에 따라 실험을 진행하였다. 이들의 운동역학적인 변화를 알아보기 위해 3차원적 관절 운동역학적 변화 검사인 6-camera Vicon MX motion analysis system을 통해 보행 변수를 측정하였다. 팔 흔들기에 따른 운동역학적인 매개 변수들인 각 관절에서 보행속도, 엉덩관절 일률, 말기 디딤기의 수직 지면반발력에서 유의한 차이를 보였다(p<.05). 이러한 연구결과는 팔 흔들기 종류에 따라서 정상인과 환자들의 치료와 평가를 위한 지침으로서 임상에서 사용할 수 있을 것으로 생각된다.

메시형 알루미늄 전극을 이용한 전기응집/부상 공정에서 Kaoline의 탁도 제거 (Turbidity Removal of Kaolin in an Electrocoagulation/Flotation Process Using a Mesh-type Aluminum Electrode)

  • 정창;김동석;박영식
    • 한국환경과학회지
    • /
    • 제26권5호
    • /
    • pp.563-572
    • /
    • 2017
  • The Electrocoagulation-Flotation (ECF) process has great potential in wastewater treatment. ECF technology is effective in the removal of colloidal particles, oil-water emulsion, organic pollutants such as microalgae, and heavy metals. Numerous studies have been conducted on ECF; however, many of them used a conventional plate-type aluminum anode. In this study, we determined the effect of changing operational parameters such as power supply time, applied current, NaCl concentration, and pH on the turbidity removal efficiency of kaoline. We also determined the effects of different electrolyte types (NaCl, $MgSO_4$, $CaCl_2$, $Na_2SO_4$, and tap water), as well as the differences caused by using a plate-type and mesh-type aluminum anode, on the turbidity removal efficiency. The results showed that the optimal values of ECF time, applied current, NaCl concentration, and pH were 5 min, 0.35 A, 0.4 g/L NaCl in distilled water, and pH 7, respectively. The results also revealed that the turbidity removal efficiency of kaoline in different electrolytes decreased in the following sequence, given the same conductivity: tap water > $CaCl_2$ > $MgSO_4$ > NaCl > $Na_2SO_4$. The turbidity removal efficiency of the mesh-type aluminum anode was significantly greater than the plate-type aluminum anode.

우리나라 실정에 알맞는 위성통신 시스템에 관한 연구

  • 강영흥;조성언;고봉진;조성준;김원후
    • 한국통신학회논문지
    • /
    • 제15권10호
    • /
    • pp.868-878
    • /
    • 1990
  • Upon introducing satellite communication system to Korea, one of the important problems to cope with is the effect from the probable intentional interference I.e. jamming. In this paper we have investigated how much the performance of ordinary PSK signal and Directed Sequence Spread Spectrum PSK signal degrade by the effect of jamming in the satellite communication system. In analysis we have consider the M ary PSK signal and the liniter type nonlinear satellite transponder in an environment of uplink tone or noise jamming plus Gaussian noise and downlink Gaussian noise. Using the derived error rate equation we have evaluated the error performance of BPSK and QPSK systems and compared this with that of DS BPSK system. Form the results, we know that the nonlinear satellite system is degraded more severely by the effect of noise jamming than tone jamming and the effect of tone jamming on the error rate performance can be reduced more remarkably by increasing the process gain in DS BPSK system rather than increasing carrier to jamming noise power ratio in conventional BPSK system.

  • PDF

THE NUMBER OF SOLUTIONS TO THE EQUATION (x + 1)d = xd + 1

  • Yim, Ji-Mi;Cho, Sung-Jin;Kim, Han-Doo;Choi, Un-Sook;Choi, Ji-Youn
    • Journal of applied mathematics & informatics
    • /
    • 제31권1_2호
    • /
    • pp.179-188
    • /
    • 2013
  • In this paper, we study the number of solutions to the equation $(x+1)^d=x^d+1$. This equation gives the value of the third power sum equation in case of Niho type exponents and is helpful in finding the distribution of the values $C_d({\tau})$. We provide the number of the solutions using the new method.

Detection and Diagnosis of Sensor Faults for Unknown Sensor Bias in PWR Steam Generator

  • Kim, Bong-Seok;Kang, Sook-In;Lee, Yoon-Joon;Kim, Kyung-Youn;Lee, In-Soo;Kim, Jung-Taek;Lee, Jung-Woon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.86.5-86
    • /
    • 2002
  • The measurement sensor may contain unknown bias in addition to the white noise in the measurement sequence. In this paper, fault detection and diagnosis scheme for the measurement sensor is developed based on the adaptive estimator. The proposed scheme consists of a parallel bank of Kalman-type filters each matched to a set of different possible biases, a mode probability evaluator, an estimate combiner at the outputs of the filters, a bias estimator, and a fault detection and diagnosis logic. Monte Carlo simulations for the PWR steam generator in the nuclear power plant are provided to illustrate the effectiveness of the proposed scheme.

  • PDF

$\mu$-Step 구동방식에 의한 LPM의 제어 (LPM Control by $\mu$-Step drive method)

  • 백수현;윤신용;김용;임태빈;김철진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.287-289
    • /
    • 1995
  • In this paper, We applied the $\mu$-stepping method on the Phase Excitation Sequence of Hybrid type LPM. Linear Pulse Motor can opeate in an open loop control as an effective positioning actuator. PWM driver was used for low power loss and automatically adjusted voltage at rate current. Finally we find that through the position-velocity for timing Triangular and Trapezoidal Profile are very affected by velocity and acceleration parameter.

  • PDF