• Title/Summary/Keyword: power system analysis

Search Result 9,412, Processing Time 0.042 seconds

Design, Implementation of the Bulk Power Stabilizing System to ensure the appropriate Power System Reliability (적정 공급신뢰도 확보를 위한 안정화장치 구성 및 설치운영)

  • Kim, Chang-Mu;Lee, Hyo-Sang;Lee, Seung-Unn;Kim, Sok-Il
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1510-1513
    • /
    • 1999
  • Carried out simulation for yearly peak and March load time of the KEPCO Power System in 1999. Analysis of the problems in power system operation by powerflow, fault and stability study. Establishment of power system optimal operating plan by installation of power system stabilizer.

  • PDF

A study on the Engine Mounting System of the 4WD Vehicle by Experimental Modal Analysis (실험적 모우드해석을 통한 4WD 자동차의 엔진마운트에 관한 연구)

  • 사종성;김광식
    • Journal of KSNVE
    • /
    • v.1 no.1
    • /
    • pp.39-43
    • /
    • 1991
  • In this study, the design concept of engine for 4WD vehicle is established by the experimental modal analysis. First, the relationships between frame and power transmission system are considered. Second, the effect of additional system (Front propeller shaft and Exhaust system) on the power transmission system is evaluated. As a result, it is desirable that of frame and power transmission system is shifted by the additional system. This is cause by the moment of inertia of the additional system, because the center of gravity location of the additional system is far from that of the power transmission system.

  • PDF

Development of the Integrated System for Power System Operational Planning an (전력수급계획 및 운용해석 종합시스템 개발)

  • Park, Si-Woo;Yoon, Yong-Beum;Nam, Jae-Hyun;Ahn, Yang-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1042-1045
    • /
    • 1998
  • The main purpose of HITES(Highly Integrate Total Energy System) is to build and develop an integrated energy system for power system operational planning and analysis which consists of load forecast, economic generation schedule, stability analysis and relational database system. The integrated energy system can be utilized to supply a stable electric power and operate KEPCO power system facilities economically. This system will be put into operation in 1999. This paper describes the main feature of the HITES, system main functions, numerical methods adopted this system, and network configuration.

  • PDF

A Study on the Improving Power System Reliability According to the Reactive Power Problem in the Bulk Power Station (대전원단지의 무효전력 출력제약에 따른 영향에 대한 연구)

  • Song, Seok-Ha;Joo, Joan-Young
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.73-75
    • /
    • 2002
  • This paper presents the properly method of system security and facility countermeasures. We performed simulation for yearly peak of Korean power system in 2002 under the reactive power problem in a nuclear power plants. Analysis of the problems in power system operation by power flow, fault and stability study. Establishment of power system optimal operating plan by stabilizer and maintaining the reasonable voltage level.

  • PDF

Study on the Real-Time Leak Monitoring Technique for Power Plant Valves (발전용 밸브누설 실시간 감시기술 연구)

  • Lee, S.G.
    • Journal of Power System Engineering
    • /
    • v.11 no.1
    • /
    • pp.39-44
    • /
    • 2007
  • The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the major valves at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized temperature water and steam flowed through glove valve(main steam dump valve) and check valve(main steam outlet pump check valve) on the normal size of 12 and 18". The valve internal leak monitoring system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, frequency analysis, voltage analysis and amplitude analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF

Voltage and Transient State Analysis of Distribution Line connected to Wind Power Generation (풍력발전이 연계된 배전선로 전압 및 과도상태 해석)

  • Kim, Se-Ho;Na, Kyoung-Yoon;Kim, Gun-Hoon
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.2
    • /
    • pp.61-67
    • /
    • 2006
  • The use of the wind energy resource is a rapidly growing area world-wide. The number of installed units is continuously increasing, and therefore, it is important to respect and to deal with the impact of wind power generation system. From the view of an electric grid utility, there is a major problem with the impact of the wind system on the voltage of the electric grid, to which a turbine is connected. In this paper, it is investigated the voltage impact and transient state analysis on distribution line, with which wind power generation system is connected. Connections of wind power system usually occur to voltage drop due to reactive power absorption and sometime result in higher than nominal voltage.

Economic Analysis of Jeju Island Power System Outage Using Event Study (이벤트 스터디 기법을 이용한 제주 정전의 경제적 파급효과 분석)

  • Kim, Jin-A;Lee, Jae-Hee;Lee, Jong-Uk;Joo, Sung-Kwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.1
    • /
    • pp.46-50
    • /
    • 2010
  • Power system outages can lead to huge economic losses for various industries. Jeju island power system outage in 2006 also caused significant social and economic impacts in Korea. There have been numerous attempts to evaluate the economic costs of power system outages. Power system outages can also have financial impacts on electric power industry. This paper attempts to analyze the economic impacts of the 2006 Jeju island power system outage on the values of the firms in the power industry using event study. Empirical analysis results are presented to show the economic impacts of the 2006 Jeju island outage on the values of the firms in the power industry.

A study on application of aggregation method based on power flow matching technique and multi-variable control method to the power system (선로 조류 유지 기법에 근거한 계통축약 및 다변수 제어기법 적용 연구)

  • Lee, Byung-Ha;Oh, Min-Hyuk;Baek, Jung-Myoung
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.342-344
    • /
    • 2006
  • The modem enormous electric power system has made power system analysis much more complex and difficult. For effective analysis of the power system, model reduction and aggregation is required. In this paper, a new aggregation method is presented to aggregate the coherent generators in the large scale power system while matching the power flow. In order to demonstrate the effects of this aggregation method, it is applied to a small scale power system. A multi-variable control technique of $H_{\infty}$ control is also applied to enhance the dynamic stability of the aggregated power system.

  • PDF

A Probabilistic Approach to Small Signal Stability Analysis of Power Systems with Correlated Wind Sources

  • Yue, Hao;Li, Gengyin;Zhou, Ming
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1605-1614
    • /
    • 2013
  • This paper presents a probabilistic methodology for small signal stability analysis of power system with correlated wind sources. The approach considers not only the stochastic characteristics of wind speeds which are treated as random variables with Weibull distributions, while also the wind speed spatial correlations which are characterized by a correlation matrix. The approach based on the 2m+1 point estimate method and Cornish Fisher expansion, the orthogonal transformation technique is used to deal with the correlation of wind farms. A case study is carried out on IEEE New England system and the probabilistic indexes for eigenvalue analysis are computed from the statistical processing of the obtained results. The accuracy and efficiency of the proposed method are confirmed by comparing with the results of Monte Carlo simulation. The numerical results indicate that the proposed method can actually capture the probabilistic characteristics of mode properties of the power systems with correlated wind sources and the consideration of spatial correlation has influence on the probability of system small signal stability.

A Web-based Educational Tool for the Power System Engineerings (전력계통공학을 위한 웹기반 교육시스템의 개발)

  • Lee, W.H.;Park, I.K.;Lee, Jin;Yoon, Y.B.;Jeon, D.H.;Hong, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.41-43
    • /
    • 2001
  • This paper presents a Web-based educational tool for Power System Engineering, especially for power engineers. This tool has Web-oriented educational courses for power system education. The Web-based learning has become more popular year by year in the various fields[1-2]. The proposed educational tool provides some courses such as power system introduction Course, KEPCO's system introduction Course, Power system devices Course, Power Flow Course, OPF Course, ELD Course, Stability Analysis Course, Fault analysis Course, Voltage & Frequency control Course, and power system planning & operation Course. Finally, it will be scheduled to install for the education tool of the power system engineering for KEPS[3].

  • PDF