• Title/Summary/Keyword: power series method

Search Result 843, Processing Time 0.033 seconds

A Study of MPPT Control Algorithm for Boost Converter of Photovoltaic System Considering Capacitor Equivalent Series Resistance (커패시턴스 내부저항을 고려한 태양광용 Boost 컨버터에 대한 MPPT 제어 알고리듬 고찰)

  • Choi J. Y.;Yu G. J.;Lee D. G.;Lee K. O.;Jung Y. S.;Kim K. H.
    • Proceedings of the KIPE Conference
    • /
    • 2001.12a
    • /
    • pp.109-114
    • /
    • 2001
  • Photovoltaic systems normally use a maximum power point tracking (MPPT) technique to continuously deliver the highest possible power to the load when variations in the insolation and temperature occur. A simple method of tracking the maximum power points (MPPs) and forcing the boost converter system to operate close to these points is presented through deriving small-signal model and transfer function of boost converter. This paper aims at modeling boost converter including equivalent series resistance of input reservoir capacitor by state-space-averaging method. In the future, properly designed controller for compensation will be constructed for maximum photovoltaic power tracking control.

  • PDF

A Hybrid Correction Technique of Missing Load Data Based on Time Series Analysis

  • Lee, Chan-Joo;Park, Jong-Bae;Lee, Jae-Yong;Shin, Joong-Rin;Lee, Chang-Ho
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.4
    • /
    • pp.254-261
    • /
    • 2004
  • Traditionally, electrical power systems had formed the vertically integrated industry structures based on the economics of scale. However, power systems have been recently reformed to increase their energy efficiency. According to these trends, the Korean power industry underwent partial reorganization and competition in the generation market was initiated in 2001. In competitive electric markets, accurate load data is one of the most important issues to maintaining flexibility in the electric markets as well as reliability in the power systems. In practice, the measuring load data can be uncertain because of mechanical trouble, communication jamming, and other issues. To obtain reliable load data, an efficient evaluation technique to adjust the missing load data is required. This paper analyzes the load pattern of historical real data and then the tuned ARIMA (Autoregressive Integrated Moving Average), PCHIP (Piecewise Cubic Interpolation) and Branch & Bound method are applied to seek the missing parameters. The proposed method is tested under a variety of conditions and also tested against historical measured data from the Korea Energy Management Corporation (KEMCO).

A Study on Over Current Protection Method of Unified Power Quality Conditioners (통합 전력품질 제어기의 과전류 보호방법에 관한 연구)

  • Chae Beom-Seok;Lee Woo-Cheol;Lee Taeck-Ki;Hyun Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.543-547
    • /
    • 2001
  • A protection scheme for Unified Power Quality Conditioner (UPQC) is presented and analyzed in this paper. The proposed UPQC has the series active power filter operated as a high impedance k($\Omega$) to the fundamentals when short-circuit faults occur in the power distribution system, and three control strategies are proposed in this paper. The first is the method by detecting the fundamental source current through the p-q theory, the second is the method by detecting the fundamental component of load current in Synchronous Reference Frame(SRF) and the third is the method by detecting the input voltage. When the short-circuit fault occur in the power distribution system, the proposed scheme protects the UPQC without additional protection circuits. The validity of proposed protection scheme is investigated through simulation results.

  • PDF

Detection of Aging Modules in Solar String with Jerk Function (Jerk 함수를 적용한 태양광 스트링 내의 노후화 모듈 검출 기법)

  • Son, Han-Byeol;Park, Seong-Mi;Park, Sung-Jun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.5
    • /
    • pp.356-364
    • /
    • 2019
  • In this study, major problems, such as licensing problems due to civil complaints, deterioration of facility period, and damage of modules, are exposed to many problems in domestic businesses. Particularly, the photovoltaic (PV) modules applied to early PV systems have been repaired and replaced over the past two decades, and a new module-based aging detection method is needed to expand the maintenance market and stabilize and repair power supplies. PV modules in a PV system use a string that is configured in series to generate high voltage. However, even if only one module of the solar modules connected in series ages, the power generation efficiency of the aged string is reduced. Therefore, we propose a topology that can measure the instantaneous PV characteristic curve to determine the aging module in the solar string and the aging judgment algorithm using the measured PV characteristic curve.

A Study on the Life Cycle Cost Evaluation of the Conventional Auxiliary Power Unit for 8200 Series Electric Locomotive (8200호대 전기기관차용 기존품 보조전원장치의 수명주기비용 평가에 관한 연구)

  • Lee, Kye-Seung;Kim, Wan-il;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.2
    • /
    • pp.331-336
    • /
    • 2018
  • In this paper, the life cycle cost of the auxiliary power unit in the conventional 8200 series electric locomotive is evaluated and an effective life cycle cost reduction method is sought. For this, a life cycle cost evaluation model was proposed using IEC 60300-3-3 standard. As a result of analysis, material cost which accounted for a large percentage of preventive maintenance cost, accounted for 64% of total cost, and breakdown maintenance cost was as high as 27%. Except for the cost of preventive maintenance, the breakdown maintenance cost ratio was the highest. In order to reduce the LCC of the auxiliary power unit(APU) of the 8200 series in the future, it is necessary to reduce the material cost in case of development and to secure the high reliability according to the parts manufacturing so as to minimize the maintenance cost.

Short-term demand forecasting method at both direction power exchange which uses a data mining (데이터 마이닝을 이용한 양방향 전력거래상의 단기수요예측기법)

  • Kim Hyoung Joong;Lee Jong Soo;Shin Myong Chul;Choi Sang Yeoul
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.722-724
    • /
    • 2004
  • Demand estimates in electric power systems have traditionally consisted of time-series analyses over long time periods. The resulting database consisted of huge amounts of data that were then analyzed to create the various coefficients used to forecast power demand. In this research, we take advantage of universally used analysis techniques analysis, but we also use easily available data-mining techniques to analyze patterns of days and special days(holidays, etc.). We then present a new method for estimating and forecasting power flow using decision tree analysis. And because analyzing the relationship between the estimate and power system ceiling Trices currently set by the Korea Power Exchange. We included power system ceiling prices in our estimate coefficients and estimate method.

  • PDF

Converter Control for APU of 8200 Series Electric Locomotive using Advanced Single Phase PLL Control Method (진보된 단상 PLL 제어방법을 이용한 8200호대 전기기관차 보조전원장치용 컨버터 제어)

  • Jung, No-Geon;Lee, Eul-Jae;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.1
    • /
    • pp.211-215
    • /
    • 2017
  • The APF (All Pass Filter) method that utilizes the computational power of the controller is most commonly used. However, since the calculation of the filter coefficient is complicated, the calculation is carried out in advance. It is difficult to apply it to the frequency fluctuation environment because the coefficient value is fixed. In this paper, a new control method of single phase PLL that can be usefully used in PWM converter device for electric railway was explained. Comparison and examination of similarities and differences between the conventional APF method PLL controller method and the newly proposed modified MA filter method PLL technique were performed. The possibility of implementation of the modified MA filter method through computer simulation was analyzed. In conclusion, the method proposed as the conclusion was applied to the APU(Auxiliary Power System) of 8200 Series Electric Locomotive and its usefulness was confirmed.

Digital Control Strategy for Input-Series-Output-Parallel Modular DC/DC Converters

  • Sha, Deshang;Guo, Zhiqiang;Liao, Xiaozhong
    • Journal of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.245-250
    • /
    • 2010
  • Input-series-output-parallel (ISOP) converters consisting of multiple modular DC/DC converters can enable low voltage rating switches to be used under high voltage input applications. This paper presents a digital control strategy, which can achieve equal sharing of input voltage for a modular ISOP system consisting of two-transistor forward DC/DC converters by forcing the input voltages of neighboring modules to be equal. The proposed scheme is analyzed using small signals analysis based on the state space average method. The performance of the proposed control strategy is verified with an experimental prototype of an ISOP converter made up of three two-switch forward converters.

Reliability Evaluation of a Capacitated Two-Terminal Network (내용을 고려한 무방향 네트워크의 신뢰도 계산)

  • 최명호;윤덕균
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.12 no.20
    • /
    • pp.47-53
    • /
    • 1989
  • This paper presents an algorithm CAPFACT to evaluate the reliability of a capacitated two terminal network such as a communication network, a power distribution network, and a pipeline network. The network is good(working) if and only if it is possible to transmit successfully the required system capacity from one specified terminal to the other. This paper defines new Capacitated series-parallel reduction to be applied to a series-parallel structure of the network. New Capacitated factoring method is applied to a non-series-parallel structure. The method is based on the factoring theorem given by Agrawal and Barlow. According to the existing studies on the reliability evaluation of the network that the capacity is not considered, the factoring method using reduction is efficient. The CAPFACT is more efficient than Aggarwal algorithm which enumerated and combined the paths. The efficiency is proved by the result of testing the number of operations and cpu time on FORTRAN compiler of VAX-11/780 at Hanyang University.

  • PDF

Elevator's Car Auxiliary Power System using the Contactless Power Transmission Method (비접촉 전력전송방식을 이용한 엘리베이터 카 보조 전원시스템)

  • Lim, Eung-Kyu;Rho, Sung-Chan;Kim, Soo-Hong;Kim, Ji-Min;Kim, Youn-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.80-84
    • /
    • 2008
  • In this paper, we have posed contactless power supply method using the contactless transformer with multiple primary winding. Also, the system uses resonant frequency tracking method for safe power supply at the elevator's car. The proposed system has been verified by the simulation using ICA4 and Maxwell. The contactless power transmission system is designed for 5[kW] rate.