• 제목/요약/키워드: power regulation methods

검색결과 124건 처리시간 0.024초

배전계통의 전압조정기 운영방법에 따른 분산형전원 최대 도입 용량 산출 (The Maximum Installable DG Capacity According to Operation Methods of Voltage Regulator in Distribution Systems)

  • 김미영
    • 전기학회논문지
    • /
    • 제58권7호
    • /
    • pp.1263-1269
    • /
    • 2009
  • Stable and sustainable power supply means maintaining a certain level of power quality and service while securing energy resource and resolving environmental issues. Distributed generation (DG) has become an essential and indispensable element from environmental and energy security perspectives. It is known that voltage violation is the most important constraint for load variation and the maximum allowable DG. In distribution system, sending voltage from distribution substation is regulated by ULTC (Under Load Tap Changer) designed to maintain a predetermined voltage level. ULTC is controlled by LDC (Line Drop Compensation) method compensating line voltage drop for a varying load, and the sending voltage of ULTC calls for LDC parameters. The consequence is that the feasible LDC parameters considering variation of load and DG output are necessary. In this paper, we design each LDC parameters determining the sending voltage that can satisfy voltage level, decrease ULTC tap movement numbers, or increase DG introduction. Moreover, the maximum installable DG capacity based on each LDC parameters is estimated.

외항선사(外航船社)의 수출입(輸出入) 컨테이너 내항운송(內航運送) 허용(許容)에 따른 문제점(問題點)과 내항해운(內航海運)의 육성방안(育成方案) (Permission of Costal Carriage of Import-Export Containers by Ocean Liner Carriers and Growth Plan of Costal Shipping Industry)

  • 하영석;정근존
    • 무역상무연구
    • /
    • 제19권
    • /
    • pp.96-118
    • /
    • 2003
  • Government tries to revise the article 25 in Korea Maritime Transport Act which describes subject of coastal carriage for exported-imported container cargoes. The subject of coastal carriage will be replaced coastal carrier by ocean liner carrier according to the revised article 25. By adopting the revised article, coastal shipping industry will be deteriorated in terms of returns on investment, sales and etc. Even though the revision is inevitable to harmonize the flow of exported-imported container cargo movement, coastal shipping industry should be developed and restructured to get competitive power and to set up an efficient international logistics system. To enhance competitive power of coastal shipping companies successfully, government must realize the importance of coastal shipping, and aid the industry through various methods such as arrangement of law and regulation, indirected financial assistance, decrease of tax rate, etc.

  • PDF

인터넷을 이용한 DLC(Direct Load Control)의 구성 및 부하제어기법 (A Configuration of DLC(Direct Load Control) Using Internet Communication and Load Control Method)

  • 이재경;김인수;김형중;이승윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.60-64
    • /
    • 2001
  • Recent recovery of the Korean economy drives a rapid increase in utility consumption and requires more stable utility supply and maintenance. However, power location security hardship, reinforcement of international environmental regulation and a huge cost of power plant construction have increased the burden laid on the stable supply. In addition, an efficient and flexible load management is required more than any era since an increment of the rate of increase in cooling load is expected. Therefore, according as the necessity of direct load control for cooling load during the summer in Korea was on the rise, direct load control systems by Internet communication method are constructed at five commercial buildings. Based on practical load control, this study proposes various application modes and communication methods prior to extension diffusion of direct load control hereafter.

  • PDF

폭력을 경험한 중소병원 간호사의 전문직 삶의 질 구조모형 (A Structural Equation Model of Professional Quality of Life for Nurses Working in Small and Medium Hospitals Who Have Experienced Violence)

  • 강애정;전미양
    • 가정∙방문간호학회지
    • /
    • 제27권1호
    • /
    • pp.29-41
    • /
    • 2020
  • Purpose: This study aimed to investigate the influence of post-traumatic stress on professional quality of life as mediated by cognitive emotion regulation among nurses working in small and medium hospitals who have experienced violence and to develop and test a structural equation model of that professional quality of life. Methods: Participants were 215 nurses who had experienced violence working in medium and small hospitals. They were surveyed using a structured questionnaire. Results: The final model was shown to have good fit with χ2 (2.83), GFI (.90), TLI (.90), and CIF (.90). Therefore, the model was selected as the final model, supporting 7 of the 11 hypotheses. Post-traumatic stress, adaptive emotional regulation, and maladaptive emotional regulation had significant impacts on empathy satisfaction (professional quality of life subscale) and empathy fatigue (subscale of professional life quality) among nurses who had experienced violence, and the explanatory power of these variables was 28.7% and 38.6%, respectively. Conclusion: In the development of nursing intervention programs to improve the professional quality of life of nurses who have experienced violence, factors such as post-traumatic stress and cognitive emotion regulation (adaptive and maladaptive) should be considered as they were identified in this study as influencing the professional quality of life of such nurses in medium and small hospitals.

Allocation of Energy Storage Capacity for Large Wind Farms in Korea using Discrete Fourier Transform

  • Moon, Seung-pil;Labios, Remund;Chang, Byung-hoon;Kim, Soo-yeol;Yoon, Yong-beum
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권3호
    • /
    • pp.377-382
    • /
    • 2016
  • In 2013, a total capacity of 591.3 MW of installed wind power generation was achieved in Korea, with a total of 1,139 MWh of wind energy generated that year. More wind power plants will be installed in the coming years, and it is important to develop methods to reduce the output variability of these resources so as to provide stable power to the power grid of Korea. In this regard, this paper proposes the use of energy storage system (ESS) as a means to stabilize the output variability of wind power plants. Presented in this paper is a method that uses Discrete Fourier Transform (DFT) to determine the ESS capacity needed to provide a stable power output for ancillary services such as frequency regulation, economic dispatch, and emergency reserves. In the first step of the proposed method, four regions (namely, Samdal, Yeongdeok, Yeongyang, and Gangwon) in Korea that had the most wind power generation capacity were selected for analysis. In the second step, the individual and aggregated wind power outputs of the selected regions in 2013 were obtained This information was then used in the third step, where DFT analysis of the power outputs was used to drive the magnitudes of the output variation. And finally, the ESS capacity requirements needed to provide different ancillary services were determined based on the magnitudes of the output variation.

V2G 전기자동차의 부하관리 자원 활용을 위한 적정 지원금 산정에 관한 연구 (A Study on the Decision of Appropriate Subsidy Levels Regarding Electric Vehicles for V2G as Load Management Resources)

  • 김정훈;황성욱
    • 전기학회논문지
    • /
    • 제65권2호
    • /
    • pp.264-268
    • /
    • 2016
  • Recently, various energy efficiency optimization activities are ongoing globally by integrating conventional grids with ICT (Information and Communication Technology). In this sense, various smart grid projects, which power suppliers and consumers exchange useful informations bilaterally in real time, have been being carried out. The electric vehicle diffusion program is one of the projects and it has been spotlighted because it could resolve green gas problem, fuel economy and tightening environmental regulations. In this paper, the economics of V2G system which consists of electric vehicles and the charging infrastructure is evaluated comparing electric vehicles for V2G with common electric vehicles. Additional benefits of V2G are analyzed in the viewpoint of load leveling, frequency regulation and operation reserve. To find this benefit, electricity sales is modeled mathematically considering depth of discharge, maximum capacity reduction, etc. Benefit and cost analysis methods with the modeling are proposed to decide whether the introduction of V2G systems. Additionally, the methods will contribute to derive the future production and the unit cost of electric vehicle and battery and to get the technical and economic analysis.

Circuit Design and Performance Analysis of CCFL Dimming Controller With Frequency Modulation

  • Kim, Cherl-Jin;Ji, Jae-Geun;Yoon, Shin-Yong
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제4B권4호
    • /
    • pp.201-205
    • /
    • 2004
  • The CCFL dimming control methods are generally used lamp current regulation or average current adjustment method feeding the CCFL inverter. Inverter operation frequency is higher than resonant frequency for safe operation. In this study, we design the half-bridge type series and parallel resonant converter circuit that switches at variable frequency modulation methods to control the output power. This method has advantages such as low EMI and reduced harmonics, and it is convenient for dimming control using a microprocessor. The validity of this study is confirmed from the simulation and experimental results.

다상 동기 벅 컨버터의 Current Sensing 방법의 비교 연구 (Comparative Study on Current Sensing Method of Multi-Phase Synchronous Buck Converter)

  • 김정훈;조경식;임정규;정세교
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 추계학술대회 논문집
    • /
    • pp.28-30
    • /
    • 2007
  • For the design of the voltage regulation module(VRM) having a high performance, current sensing is one of the most important functions. In this paper, three different methods for sensing the current in the multi-phase synchronous buck converter are analyzed considering the efficiency, accuracy and cost. The experiments are performed for the three current sensing methods to verify the theoretic analysis.

  • PDF

옥내변전소 운전상황에 따른 변압기 소음예측 (The Prediction of Transformer Noise by Operating Situation at the Indoor Substation)

  • 구교선;권동진;곽주식
    • 조명전기설비학회논문지
    • /
    • 제22권10호
    • /
    • pp.104-110
    • /
    • 2008
  • 최근 생활수준의 향상으로 쾌적한 주거환경에 대한 요구가 증대되어, 변압기 소음으로 인한 민원이 끊임없이 발생하고 있다. 소음민원을 해결하기 위하여 옥내변전소에서는 공명형 소음기, 방음보조셔터 등의 대책을 시행하고 있으나, 주변환경 변화에 따라 소음대책을 재수립하는 경우가 발생한다. 따라서 소음문제를 근본적으로 해결하기 위해서는 변압기의 소음전파를 예측하여, 변전소 경계지역에서 소음규제기준을 만족시키는 변압기 소음레벨을 제시할 필요가 있다. 본 논문에서는 옥내변전소에서 변압기 증설, 주변압기실 셔터의 개방 등의 운전상황에 따른 소음레벨 변화를 예측하고, 옥내변전소 경계지역에서 소음규제기준을 만족시키는 변압기 소음레벨을 제시하였다.

해양플랜트 프로세스 배관 Pressure Leak Test의 품질 특성에 관한 연구 (A Study on a Quality Characteristics of Pressure Leak Test of Process Piping for Offshore Plant)

  • 박창수;김형우
    • 한국산업융합학회 논문집
    • /
    • 제21권6호
    • /
    • pp.429-437
    • /
    • 2018
  • The process gas piping of the offshore plant can cause a massive explosion if the gas leakage occurs during operation. For the purpose of precaution of gas leakage accident, an air pressure test is performed on the process equipment tests using a test pump as much as the power to the piping inner side, mix 99% nitrogen gas and 1% helium gas. The purpose of the air pressure test is to check the work conformity process by handling and regulation for initial piping process, assembly, installation of module, welding, center alignment of the pipes assembling flange gasket in an unrestrained free state. In this paper, the regulation of the problematic air pressure test was analyzed and the solution criteria were established. And leakage tests of existing equipment were performed applying these solution methods. As a result, it was confirmed that there was no problem.