• Title/Summary/Keyword: power parameter

Search Result 2,736, Processing Time 0.031 seconds

Incomplete Relationship between Dominant Power of Electrogastrography and Gastric Myoelectrical Activity in Patients with Functional Dyspepsia

  • Han, Sook-Young;Yoon, Sang-Hyub;Kim, Jin-Sung;Rhyu, Bong-Ha;Rhyu, Ki-Won
    • The Journal of Korean Medicine
    • /
    • v.24 no.4
    • /
    • pp.92-101
    • /
    • 2003
  • Background & Aims : The aim of this study was to investigate the change of dominant power with observation of gastric myoelectrical activity and its parameter linkage in electrogastrography. Methods : Electrogastrography was performed on a total of 123 subjects (113 patients with functional dyspepsia, 10 healthy controls) for 30 min in fasting state and 50 min in postprandial state. Average myoelectrical activity per frequency and accumulated electrical activity of 5 min duration in each bradygastria, normogastria, and tachygastria were measured at the moment of frequency switchover of slow wave. Assumed parameter linkages were also investigated among dominant frequency, % of normal regularity, and dominant power (or power ratio). Results : Average myoelectrical activity per frequency was highest in bradygastria (mean 1.10-1.47 Volt/s), next highest in normogastria (mean 0.50-0.82 Volt/s), and lowest in tachygastria (mean 0.44-0.47 Volt/s). Average accumulated myoelectrical activity was highest in normogastria (mean 114.90-126.29 Volt/ss), next highest in tachygastria (mean 71.02-90.00 Volt/ss), and lowest in bradygastria (mean 12.93-51.94 Volt/ss). Significance of parameter linkages were noted in dominant frequency (p< 0.01) and in % of normal regularity (p< 0.01), but not in dominant power in case of frequency shift from bradygastria to normogastria (p=0.376). Conclusion : Dominant power is not a parameter that reflects the gastric myoelectrical activity related with only gastric contraction. Bradygastric dominant power does not follow the inter-parameter linkage of electrogastrography for gastric motility assessment.

  • PDF

Bayesian Parameter Estimation of the Four-Parameter Gamma Distribution

  • Oh, Mi-Ra;Kim, Kyung-Sook;Cho, Wan-Hyun;Son, Young-Sook
    • Communications for Statistical Applications and Methods
    • /
    • v.14 no.1
    • /
    • pp.255-266
    • /
    • 2007
  • A Bayesian estimation of the four-parameter gamma distribution is considered under the noninformative prior. The Bayesian estimators are obtained by the Gibbs sampling. The generation of the shape/power parameter and the power parameter in the Gibbs sampler is implemented using the adaptive rejection sampling algorithm of Gilks and Wild (1992). Also, the location parameter is generated using the adaptive rejection Metropolis sampling algorithm of Gilks, Best and Tan (1995). Finally, the simulation result is presented.

Study of Optimal Design Parameter for Gearbox on Wind Power System (풍력발전시스템용 증속기의 최적화 설계요소에 관한 연구)

  • 이근호;성백주;최용혁
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.737-741
    • /
    • 2003
  • The wind power system is spotlighted as one of the no-pollution power generation systems. The system uses winds as power source that are rotated the blade and the rotating power from blade generate the electricity power. Gearbox needs to transfer the wind powers that have the high-torque-low-speed characteristics to generator that have the low-torque-high-speed characteristics. Because the wind power system generally locates the remote place like seaside or mountainside and the gearbox installs on the limited and high placed space, the gearbox of the wind power system is required the optimal space design and high reliability. In this paper, the structure of the gearbox is proposed to achieve the optimal space and efficiency by compounding the planetary gear train that has the high power density and parallel type gear train that has the long service life. The design parameters that are affected the service life are studied. The gear ratio and face width are investigated as an affected parameter for design sensitivity of service life.

  • PDF

A Parameter Estimation of Time Signal and Analysis of Low Frequency Oscillation in Power Systems (시간영역에서 파라미터 추정과 전력계통의 저주파진동 해석)

  • Shim Kwan-Shik;Nam Hae-Kon;Kim Yong-Gu
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.3
    • /
    • pp.122-132
    • /
    • 2005
  • This paper presents a novel approach based on Prony method to analysis of small signal stability in power system. Prony method is a valuable tool in identifying transfer function and estimating the modal parameter of power system oscillation from measured or computed discrete time signal. This paper define the relative residue of time signal and propose the condition to select low frequency oscillation in each generator. This paper describes the application results of proposed algorithm with respect to KEPCO systems. Simulation results show that the proposed algorithm can be used as another tools of power systems analysis.

Instantaneous Current Control for Parallel Inverter with a Current Share Bus (전류공유버스를 이용한 병렬 인버터 순시 제어기 설계)

  • 이창석;김시경
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.90-94
    • /
    • 1998
  • The parallel inverter is popularly used because of its fault-tolerance capability, high-current outputs at constant voltages and system modularity. The conventional parallel inverter usually employes active and reactive power control or frequency and voltage droop control. However, these approaches have the disadvantages that the response time of parallel inverter control is slow against load and system parameter variation to calculate active, reactive power, frequency and voltage. This paper describes a novel control scheme for power equalization in parallel connected inverter. The proposed scheme has a fast power balance control response, a simplicity of implementation, and inherent peak current limiting capability since it employes a instantaneous current/voltage control with output voltage and current balance and output voltage regulation. A design procedure for the proposed parallel inverter controller is presented. Futhermore, the proposed control scheme is verified through the simulation in various cases such as the system parameter variation, the control parameter variation and the nonlinear load condition.

  • PDF

A Current Sharing Circuit for the Parallel Inverter

  • Lee, Chang-Seok;Kim, Si-Kyung
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.176-181
    • /
    • 1998
  • The parallel inverter is popularly used because of its fault-tolerance capability, high-current outputs at constant voltages and system modularity. The conventional parallel inverter usually employs active and reactive power control of frequency and voltage droop control. However, these approaches have the disadvantages that the response time of parallel inverter control is slow against load and system parameter variation to calculate active, reactive power, frequency and voltage. This paper describes a novel control scheme for power equalization in parallel-connected inverter. The proposed scheme has a fast power balance control response, a simplicity of implementation, and inherent peak current limiting capability since it employees an instantaneous current/voltage control with output voltage and current balance and output voltage regulation. A design procedure for the proposed parallel inverter controller is presented. Furthermore, the proposed control scheme is verified through the experiment in various cases such as the system parameter variation, the control parameter variation and the nonlinear load condition.

  • PDF

A Method of Tuning Optimization for PID Controller in Nuclear Power Plants (원자력발전소 PID 공정제어기에 대한 튜닝 최적화 방법)

  • Sung, Chan Ho;Min, Moon Gi
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • PID(Proportional, Integral, Derivative) controller is one of the most used process controllers in nuclear power plants. The optimized parameter setting of process controller contributes to the stable operation and efficiency in the operating nuclear power plants. PID parameter setting is tuned when new process control system is established or process control system is changed. It is a burdensome work for I&C(Instrument and Control) engineers to tune the PID controller because it requires a lot of experience and knowledge. When the plant is in operation, inadequate PID parameter setting can be the cause of the unstable process of the plant. Therefore the results of PID parameter setting should be compared, simulated, verified and finally optimized. The practical PID tuning methods used in process controller are tuning operation calculation(Ziegler-Nicholes, Minimum TIAE, Lambda, IMC), exclusive tuning program based on computer and Matlab application. This paper introduces the various tuning methods and suggests an optimized PID tuning process in the operating nuclear power plants.

A Fast Parameter Estimation of Time Series Data Using Discrete Fourier Transform (이산푸리에변환과 시계열데이터의 고속 파라미터 추정)

  • Shim, Kwan-Shik;Nam, Hae-Kon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.7
    • /
    • pp.265-272
    • /
    • 2006
  • This paper describes a method of parameter estimation of time series data using discrete Fourier transform(DFT). DFT have been mainly used to precisely and rapidly obtain the frequency of a signal. In a dynamic system, a real part of a mode used to learn damping characteristics is a more important factor than the frequency of the mode. The parameter estimation method of this paper can directly estimate modes and parameters, indicating the characteristics of a dynamic system, on the basis of the Fourier transform of the time series data. Real part of a mode estimates by subtracting a frequency of the Fourier spectrum corresponding to 0.707 of a magnitude of the peak spectrum from a peak frequency, or subtracting a frequency of the power spectrum corresponding to 0.5 of the peak power spectrum from a peak frequency, or comparing the Fourier(power) spectrum ratio. Also, the residue and phase of time signal calculate by simple equation with the real part of the mode and the power spectrum that have been calculated. Accordingly, the proposed algorithm is advantageous in that it can estimate parameters of the system through a single DFT without repeatedly calculating a DFT, thus shortening the time required to estimate the parameters.

A Maximum Power Control of IPMSM with Real-time Parameter Identification

  • Jun, Hyunwoo;Ahn, Hanwoong;Lee, Hyungwoo;Go, Sungchul;Lee, Ju
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.110-116
    • /
    • 2017
  • This paper proposed a new real-time parameter tracking algorithm. Unlike the convenience algorithms, the proposed real-time parameter tracking algorithm can estimate parameters through three-phase voltage and electric current without coordination transformation, and does not need information on magnetic flux. Therefore, it can estimate parameters regardless of the change according to operation point and cross-saturation effect. In addition, as the quasi-real-time parameter tracking technique can estimate parameters through the four fundamental arithmetic operations instead of complicated algorithms such as numerical value analysis technique and observer design, it can be applied to low-performance DSP. In this paper, a new real-time parameter tracking algorithm is derived from three phase equation. The validity and usefulness of the proposed inductance estimation technique is verified by simulation and experimental results.

Online Parameter Estimation for Wireless Power Transfer Systems Using the Tangent of the Reflected Impedance Angle

  • Li, Shufan;Liao, Chenglin;Wang, Lifang
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.300-308
    • /
    • 2018
  • An online estimation method for wireless power transfer (WPT) systems is presented without using any measurement of the secondary side or the load. This parameter estimation method can be applied with a controlling strategy that removes both the receiving terminal controller and the wireless communication. This improves the reliability of the system while reducing its costs and size. In a wireless power transfer system with an LCCL impedance matching circuit under a rectifier load, the actual load value, voltage/current and mutual inductance can be reflected through reflected impedance measuring at the primary side. The proposed method can calculate the phase angle tangent value of the secondary loop circuit impedance via the reflected impedance, which is unrelated to the mutual inductance. Then the load value can be determined based on the relationships between the load value and the secondary loop impedance. After that, the mutual inductance and transfer efficiency can be computed. According to the primary side voltage and current, the load voltage and current can also be detected in real-time. Experiments have verified that high estimation accuracy can be achieved with the proposed method. A single-controller based on the proposed parameter estimation method is established to achieve constant current control over a WPT system.