• Title/Summary/Keyword: power oscillation

Search Result 541, Processing Time 0.025 seconds

The operational characteristics of the AT Forward Multi-Resonant Converter (AT 포워드 다중 공진형 컨버터의 동작 특성)

  • 김창선
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.3
    • /
    • pp.114-123
    • /
    • 1998
  • The multi-resonant converter(MRC) minimizes a parasitic oscillation by using the resonant tank circuit absorbed parasitic reactances existing in a converter circuit. So it si possible that the converter operated at a high frequency has a high efficiency because the losses are reduced. Such a MHz high frequency applications provide a high power density [W/inch3] of the converter. But the resonant voltage stress across a switch of the resonant tank circuit is 4~5 times a input voltage. This h호 voltage stress increases the conduction loss because of on-resistance of a MOSFET with higher rating. Thus, in this paper we proposed the alternated multi-resonant converter (AT MRC) differ from the clamp mode multi-resonant converter and applicated it to the forward MRC. The AT forward MRC can reduce the voltage stress to 2~3 times a input voltage by using two series input capacitor. The control circuit is simple because tow resonant switches are driven directly by the output pulse of the voltage controled oscillator. This circuit type is verified through the experimental converter with 48V input voltage, 5V/50W output voltage/power and PSpice simulation. the measured maximum voltage stress is 170V of 2.9 times the input voltage and the maximum efficiency of 81.66% is measured.

  • PDF

Single-Stage Quasi Resonant Type PSR(Primary Side Regulation) PWM Converter for the LED Drive in TRIAC Phase Controlled Dimmer (TRIAC위상 제어 조광기에서의 LED구동을 위한 Single-Stage 준 공진형 PSR(Primary Side Regulation) PWM 컨버터)

  • Han, Jae-Hyun;Lim, Young-Cheol;Jung, Young-Gook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.2
    • /
    • pp.84-94
    • /
    • 2013
  • In case when the existing TRIAC phase controlled dimmer is drove for the LED lighting equipments, there are many problems such as the LED flicker in low phase-angles, the acoustic noise and elements damage by increase of the peak voltage in the input filter capacitor, mulfunction by insufficiency of the TRIAC holding current, and the abnormal oscillation by LC resonant. In this paper, we proposes the single-stage quasi-resonant PSR(Primary Side Regulation) PWM converter, and the design, the simulation and experiment are performed. As a result, it could confirm that the proposed PWM converter is the lighting equipments for LED drive which can alternate the existing 60W class incandescent bulbs and it has the high drive performance of the efficiency 80% and over, the power factor 0.95 and over under the normal voltage 220V. Finally, total harmonic distortion(THD) is gratified with a standard[1] of the lighting equipments and the durability is evaluated as the high reliablilty of 150,000 hours and over.

The design of high efficiency DC-DC Converter with ESD protection device for Mobile application (모바일 기기를 위한 ESD 보호 소자 내장형 고효율 DC-DC 컨버터 설계)

  • Ha, Ka-San;Son, Jung-Man;Shin, Samuell;Won, Jong-Il;Kwak, Jae-Chang;Koo, Yong-Seo
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.565-566
    • /
    • 2008
  • The high efficiency power management IC(PMIC) for Moblie application is proposed in this paper. PMIC is controlled with PWM control method in order to have high power efficiency at high current level. The saw-tooth generator is made to have 1.2 MHz oscillation frequency and full range of output swing from ground to supply voltage(VDD:3.3V). The comparator is designed with two stage OP amplifier. And the error amplifier has 70dB DC gain and $64^{\circ}$ phase margin. DC-DC converter, based on Voltage-mode PWM control circuits, achieved the high efficiency near 95% at 100mA output current. DC-DC converter is designed with LDO in stand-by mode which fewer than 1mA for high efficiency.

  • PDF

Design of High Performance On -chip Voltage Controlled Oscillator Using GaAs MESFET (GaAs MESFET을 이용한 고성능 온-칩 전압 제어 발진기 설계)

  • 김재영;이범철;최종문;최우영;김봉렬
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.12
    • /
    • pp.24-30
    • /
    • 1996
  • In this paper, we designed a new type of high frequency on-chip voltage controlled oscillator (VCO) using GaAs MESFET, and their performances were comapred with those of the conventional VCO. Each VCO was designed with three-to-five ring oscillator and inverter, buffer and NOR gate were implemented by GaAs source coupled FET logic, which has better speed and noise performance compared to other GaAs MESFET logic. SPICE simulation showed that the gain of conventional and our new VCO was 1.24[GHz/V], 0.54[GHz/V], respectively. The frquency tuning range were 2.31 to 3.55 [GHz] for conventional VCO and 2.47 to 3.01[GHz] for our new design. This shows that the factor of two gain reductin was achieved without too much sacrifice in the oscillation frequency. For our new VCO, the average temperature index was -2[MHz/.deg. C] in the range of -20~85[.deg. C] the power supply noise index was 5[MHz/%] for 5.3[V].+-.10[%] and total power consumption was 60.58[mW].

  • PDF

Evaluation and Comparison of the Low-Frequency Oscillation Damping Methods for the Droop-Controlled Inverters in Distributed Generation Systems

  • Tao, Yong;Deng, Yan;Li, Guangdi;Chen, Guipeng;He, Xiangning
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.731-747
    • /
    • 2016
  • The droop-based control strategy is widely applied in the interfacing inverters for distributed generation. This can be a problem since low-frequency stability issues may be encountered in droop-based microgrid. The objective of this paper is to classify, evaluate and compare various low-frequency damping methods. First, low-frequency stability problems are analyzed and an equivalent model of a droop-controlled inverter is investigated to classify the damping methods into the source-type damping strategies and the impedance-type damping strategies. Moreover, the lead-lag compensation network insertion control is proposed as a beneficial part of the source-type damping strategies. Then, the advantages and disadvantages of the different types of damping methods are theoretically evaluated and experimentally tested. Furthermore, the damping methods are comprehensively compared to illustrate the application field of each method. Finally, the synthesis of different damping methods to enhance the low-frequency stability is discussed and experimental validation is presented.

A Novel Zero-Voltage-Switching Push-Pull DC-DC Converter for High Input Voltage and High Power Applications

  • Mao Saijun;Wang Huizhen;Yan Yangguang
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.4
    • /
    • pp.343-349
    • /
    • 2005
  • This paper proposes a novel zero-voltage-switching (ZVS) Push-pull DC-DC Converter for high input voltage and high power applications. This topology utilizes two switches in series to replace one switch in conventional push-pull converter, and two clamping diodes are introduced. The voltage stress of the switches is the input voltage, and the switches can realize ZVS with the use of the leakage inductance of the transformer. Furthermore, secondary full-wave rectifier with a clamping capacitor is used to eliminate the voltage oscillation and spike of the rectifier diodes due to the reverse recovery. Therefore, the electromagnetic interference is reduced effectively. The operation principle of the proposed converter is analyzed theoretically. The output characteristic, ZVS condition and design principle of the clamping capacitor are discussed. Experimental results obtained from a 270V input 2kW prototype with $95.8\%$ high efficiency confirms the design.

Improvement of the CCFL Model of the RELAP5/MOD3.2.2B Code in a Horizontal Pipe

  • Heo, Sun;No, Hee-Cheon;Chang, Kyung-Sung;Ha, Sang-Jun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1999.05a
    • /
    • pp.115-115
    • /
    • 1999
  • To demonstrate the applicability of RELAP5 to the prediction of the onset offlooding in the hot leg at the reflux condensation phase during mid-loop operation, numerical analysis is performed for the counter-current flow in a horizontal pipe with the inclined riser using the RELAP5/MOD3.2.2b code. It is found that the RELAP5, simulating the CCFL phenomena using interfacial friction along with the flow regime map in the horizontal pipe, produces unsatisfactory results. Under the CCFL condition, it is observed that large oscillation exists in the flow rate, void fraction, and etc. and the liquid flow rate is much lower than that predicted by the CCFL model measured in the experiment. The CCFL model of RELAP5 for the vertical volume is extended to the model for the horizontal and inclined volumes. The horizontal volume flow regime map and interfacial friction model coupled to the CCFL model are modified. And a new correlation developed from Kang's experiment is implemented to the CCFL model of RELAP5. With this modified RELAP5, the analysis of CCFL phenomena in the horizontal pipe and hot leg geometry is performed, and produces reasonable results in comparison with experimental data.

  • PDF

Post Test Analysis to Natural Circulation Experiment on the BETHSY Facility Using the MARS 1.4 Code

  • Chung, Young-Jong;Kim, Hee-Cheol;Chang, Moon-Hee
    • Nuclear Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.638-651
    • /
    • 2001
  • The present study is to assess the applicability of the best-estimate thermal-hydraulic code, MARS 1.4, for the analysis of thermal-hydraulic behavior in PWRs during natural circulation conditions. The code simulates a natural circulation test, BETHSY test 4. la, which was conducted on the integral test facility of BETHSY. The test represented the cooling states of the primary cooling system under single-phase natural circulation, two-phase natural circulation and the reflux condensation mode with conditions corresponding to the residual power, 2% of the rated core power value and 6.8 MPa at the secondary system. Based on MARS 1.4 calculations, the major thermal-hydraulic behaviors during natural circulation are evaluated and the differences between the experimental data and calculated results are identified. The calculated results show generally good behavior with regard to the experimental results; the region of single-phase natural circulation is 100-92% of the initial mass inventory, two-phase natural circulation is 84-63 %, and the reflux condensation mode occurred below 58 %. U-tubes empty and the core uncovery are obtained at 39 % and 34 % of the initial mass inventory, respectively.

  • PDF

A Stable Startup Method of V/f Scalar Controlled Permanent Magnet Synchronous Motors (V/f 스칼라 제어 영구자석 동기 전동기의 안정적 초기 구동 기법)

  • Kim, Hyeon-Seong;Lee, Sang-Min;Lee, Kibok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.5
    • /
    • pp.395-403
    • /
    • 2020
  • This study presents a stable start-up strategy for v/f scalar-controlled permanent magnet synchronous motors (PMSMs). The v/f-controlled PMSMs easily lose synchronism under low-speed conditions if an insufficient stator voltage is applied to the machine due to errors in measured motor parameters and inverter nonlinearity, such as inverter dead time and on-state voltage drop. The proposed method adopts the I/f control method to ensure a stable start at low speeds and then switches to the v/f control method at medium speeds. A smooth transition method from I/f control to v/f control is proposed to minimize the oscillation of the stator current and rotor speed during transition. Moreover, the stability of the I/f and v/f control methods is analyzed using a small-signal model. Simulation and experimental results are provided to verify the performance of the proposed control strategy.

A Prony Method Based on Discrete Fourier Transform for Estimation- of Oscillation Mode in Power Systems (이산푸리에변환에 기초한 Prony 법과 전력계통의 진동모드 추정)

  • Nam Hae-Kon;Shim Kwan-Shik
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.6
    • /
    • pp.293-305
    • /
    • 2005
  • This paper describes an improved Prony method in its speed, accuracy and reliability by efficiently determining the optimal sampling interval with use of DFT (discrete Fourier transformation). In the Prony method the computation time is dominated by the size of the linear prediction matrix, which is given by the number of data times the modeling order The size of the matrix in a general Prony method becomes large because of large number of data and so does the computation time. It is found that the Prony method produces satisfactory results when SNR is greater than three. The maximum sampling interval resulting minimum computation time is determined using the fact that the spectrum in DFT is inversely proportional to sampling interval. Also the process of computing the modes is made efficient by applying Hessenberg method to the companion matrix with complex shift and computing selectively only the dominant modes of interest. The proposed method is tested against the 2003 KEPCO system and found to be efficient and reliable. The proposed method may play a key role in monitoring in real time low frequency oscillations of power systems .