• Title/Summary/Keyword: power minimization

Search Result 457, Processing Time 0.022 seconds

GA-Based ORPD considering Transmission Losses Re-Distribution (송전손실 재분배를 고려한 유전 알고리즘 기반의 무효전력 최적배분)

  • Chae, Myung-Suck;Lee, Myung-Hwan;Kim, Byung-Seop;Shin, Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.190-192
    • /
    • 1999
  • This paper presents an algorithm for optimal reactive power dispatch problem based on genetic algorithm. Optimal reactive power dispatch is particularized to the minimization of transmission line losses by suitable selection of generator reactive power outputs and transformer tap settings. To attain for the objective, in this paper, loss re-distribution algorithm(LRDA) is applied to ORPD. The proposed method has been evaluated on the IEEE 30 bus system. Results of the application of the method are compared with a simple genetic algorithm.

  • PDF

Analysis and optimization of Wiel-Dobke synthetic testing circuit parameters (Weil-Dobke 합성단락 시험회로의 Parameter 분석과 최적화)

  • Kim, Maeng-Hyun;Rhyou, Hyeong-Kee;Park, Jong-Wha;Koh, Hee-Seog
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.623-627
    • /
    • 1995
  • This paper describes analysis and optimization of Weil-Dobke synthetic testing circuit parameters, which is efficient and economical test method in high capacity AC circuit breaker. In this paper, analysis of synthetic short-circuit test circuit parameter proposed nondimensional factor that is reciprocal comparison value of circuit parameter and is not related to rated of circuit breaker, in particular, this study induce minimization of required energy of critical TRV generation specified in IEC 56 standards and present optimal design of synthetic short circuit testing facilities.

  • PDF

Design of SOFLIC for reactor rod control system in nuclear power plant (원자력발전소 원자로 제어봉 제어계통에 대한 자기조정 퍼지제어기 설계)

  • 남해곤;문채주;최홍관
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1995.10b
    • /
    • pp.145-152
    • /
    • 1995
  • This paper presents a novel SOFLIC(self organizing fuzzy logic intelligent controller) for reactor rod control system in nuclear power plant. The output of fuzzy controller is gener ated by using two signal : the error between reference and average temperature, and the error between reference and neutron flux-converted temperatures. Flexibility of the controller is enhanced by using self-organizing feature and the controller respond to variation of system parameter with more precision. performances of the SOFLIC and PID are simulated with the model developed for a nuclear power plant. The SOFLIC is superior to PID : SOFLIC provides more rapid load following capability. more robustiness for variation in process dynamics and minimization of engineer's mistakes in controller design.

  • PDF

A MW-Mvar Investment Technique Focused on System Loss Minimization

  • Eom, Jae-Sun;Lee, Sang-Joong;Kim, Kern-Jong
    • Journal of KIEE
    • /
    • v.11 no.1
    • /
    • pp.51-54
    • /
    • 2001
  • In this paper, a MW-Mvar investment technique focused on minimizing the system loss is presented. An optimization technique, in which the system loss is defined as the objective function and the power flow equations as the constraints, is introduced to obtain the Lagrangian multipliers λP and λQ. The Lagrangian multipliers imply the variation of the system loss with respect to incremental bus power and are used as MW-Mvar investment indices for minimizing the system loss. ΔP MW and ΔQ Mvar are invested, step by step, by the priority of λP and λQ index given for each bus. Derivation of the index uses the information from normal power flow calculation.

  • PDF

Modulated Finite Control Set - Model Predictive Control for Harmonic Reduction in a Grid-connected Inverter

  • Nguyen, Tien Hai;Kim, Kyeong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.268-269
    • /
    • 2017
  • This paper presents an improved current control strategy for a three-phase grid-connected inverter under distorted grid conditions. Distorted grid condition is undesirable due to negative effects such as power losses and heating problem in electrical equipments. To enhance the power quality of distributed generation systems under such a condition, a modulated finite control set - model predictive control (MFCS-MPC) scheme will be proposed, in which the optimal switching signals of inverter are chosen by online basis using the principle of current error minimization. In addition, the moving average filter (MAF) is used to improve the phase-lock loop in order to obtain the harmonic-free reference currents on the stationary frame. The usefulness of the proposed MFCS-MPC method is proved by the comparative simulation results under different operating conditions.

  • PDF

Optimal Operation of Reactive Power Compensation Devices for Voltage Control of Emegency Status (비상상태 전압제어를 위한 무효전력보상설비의 최적 운용)

  • Ahn, Chang-Han;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.5
    • /
    • pp.661-666
    • /
    • 2015
  • This paper proposes a method for solving running cost problem by minimizing switching reactive power compensation devices. An objective function was modeled by calculating the weighting value of cost, and a solution was derived using ILP. This paper suggests optimal coordinative control method between FACTS, Shunt Reactors, Capacitors and OLTC. Therefore, it is valuable for decision maker in determining order and capacity of devices which gaining a voltage stabilization. As a result, the objectives of voltage stabilization and cost minimization were achieved simultaneously. This realizes the economic efficiency of the system. We start by showing how to solve systems of linear equations using the language of pivots and tableaus. The effectiveness of this technique is demonstrated in modified PSS/E MIGUM 45 bus system. The simulation results show the effectiveness of this algorithm by comparing the outcome withseveral established methods.

Flexible Maintenance Scheduling of Generation System by Multi-Probabilistic Reliability Criterion in Korea Power System

  • Park, Jeong-Je;Choi, Jae-Seok;Baek, Ung-Ki;Cha, Jun-Min;Lee, Kwang-Y.
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.8-15
    • /
    • 2010
  • A new technique using a search method which is based on fuzzy multi-criteria function is proposed for GMS(generator maintenance scheduling) in order to consider multi-objective function. Not only minimization of probabilistic production cost but also maximization of system reliability level are considered for fuzzy multi-criteria function. To obtain an optimal solution for generator maintenance scheduling under fuzzy environment, fuzzy multi-criteria relaxation method(fuzzy search method) is used. The practicality and effectiveness of the proposed approach are demonstrated by simulation studies for a real size power system model in Korea in 2010.

An Economic Analysis of Potential Cost Savings from the Use of Low Voltage DC (LVDC) Distribution Network

  • Hur, Don;Baldick, Ross
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.812-819
    • /
    • 2014
  • The proposed technical work attempts to compare the two key technologies of power distribution, i.e. direct current (DC) and alternating current (AC) in a fiscal manner. The DC versus AC debate has been around since the earliest days of electric power. Here, at least four types of a low voltage DC (LVDC) distribution are examined as an alternative to the existing medium voltage AC (MVAC) distribution with an economic assessment technique for a project investment. Besides, the sensitivity analysis will be incorporated in the overall economic analysis model to cover uncertainties of the input data. A detailed feasibility study indicates that many of the common benefits claimed for an LVDC distribution will continue to grow more profoundly as it is foreseen to arise with the increased integration of renewable energy sources and the proliferation of energy storage associated with the enhanced utilization of uninterruptible power supply (UPS) systems.

Analyze of High Efficiency PCS for Fuel Cell (연료전지용 3-Stage PCS의 손실 해석)

  • Ba, Yasgalan;Lee, Yong-Jin;Han, Dong-Hwa;Kim, Young-Sik;Gwon, Wang-Song;Jeong, Beong-Hwang;Shin, Woo-Sok;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2008.10a
    • /
    • pp.100-102
    • /
    • 2008
  • As Utility interactive fuel cell systems are widely used, it is required for each power conditioning system(PCS) to have higher generating performance and more stable connecting characteristics. This study is focused to minimization of power losses and hence higher efficiency related to the new half bridge type 3-stage utility interactive PCS topology. The loss factor of half-bridge converter becomes only 1.2[%] under the rated load, and hence total efficiency is maintained to be higher as 91[%].

  • PDF

Design for Cam Curve of a Oil Hydraulic Vane Pump for Vehicles′ Power Steering System (자동차 PS용 베인펌프의 캠곡선 설계)

  • 정석훈;정재연
    • Tribology and Lubricants
    • /
    • v.20 no.3
    • /
    • pp.157-162
    • /
    • 2004
  • The cam curve of a balance type vane pump consists usually of circular arcs and Archimedes' spirals. However, if they are connected directly together, the curve must have a few discontinuous points of the gradients and the motion of the vanes is no longer smooth. Designing data for an oil hydraulic vane pump used in power steering system were obtained by the acquisition of optimum cam profile data which can be available to reduce noises and vibrations through the minimization of cavitation with the improvement of suctional performance. The performance test is carried on the trial manufactures by measuring the volumetric and the mechanical efficiency. And from that result, maintaining the same characteristic as the conventional one in the relief pressure and noise level, the experimental pump discharges 0.7 $\ell$/min and shows nearly 3.5% enhancement in the total efficiency more than the conventional one.