• Title/Summary/Keyword: power loss measurement system

Search Result 101, Processing Time 0.022 seconds

Review of the measurement uncertainty of Tr no-load loss measuring system (변압기철손 측정시스템의 측정 불확도)

  • Kang, T.S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.139-141
    • /
    • 2005
  • For the reliable evaluation of the distribution and power transformer no-load loss measurement, measurement uncertainty of the transformer measuring system, consisted of current transformer, potential transformer and power metering equipment is required. In this paper, we describe the uncertainty of transformer measuring system based on ANSI/IEEE C57.12.90.

  • PDF

Field-Measurement-Based Received Power Analysis for Directional Beamforming Millimeter-Wave Systems: Effects of Beamwidth and Beam Misalignment

  • Lee, Juyul;Kim, Myung-Don;Park, Jae-Joon;Chong, Young Jun
    • ETRI Journal
    • /
    • v.40 no.1
    • /
    • pp.26-38
    • /
    • 2018
  • To overcome considerable path loss in millimeter-wave propagation, high-gain directional beamforming is considered to be a key enabling technology for outdoor 5G mobile networks. Associated with beamforming, this paper investigates propagation power loss characteristics in two aspects. The first is beamwidth effects. Owing to the multipath receiving nature of mobile environments, it is expected that a narrower beamwidth antenna will capture fewer multipath signals, while increasing directivity gain. If we normalize the directivity gain, this narrow-beamwidth reception incurs an additional power loss compared to omnidirectional-antenna power reception. With measurement data collected in an urban area at 28 GHz and 38 GHz, we illustrate the amount of these additional propagation losses as a function of the half-power beamwidth. Secondly, we investigate power losses due to steering beam misalignment, as well as the measurement data. The results show that a small angle misalignment can cause a large power loss. Considering that most standard documents provide omnidirectional antenna path loss characteristics, these results are expected to contribute to mmWave mobile system designs.

Application of Piezoelectric Smart Structures for Statistical Energy Analysis (압전 지능 구조물을 이용한 통계적 에너지 해석 기법)

  • 김재환;김정하;김재도
    • Journal of KSNVE
    • /
    • v.11 no.2
    • /
    • pp.257-264
    • /
    • 2001
  • In this research, piezoelectric smart structures are applied for SEA(Statistical Energy Analysis), which is well known approach for high frequency analysis. A new input power measurement based on piezoelectric electrical power measurement is proposed and compared with the conventional method in SEA. As an example, a simple aluminum beam on which piezoelectric actuator is attached is considered. By measuring the electrical impedance and electrical current of the piezoelectric actuator, the electrical power given on the actuator is found and this is In turn converted into the mechanical energy. From the measured value of the stored energy of the beam, the Internal loss factor is calculated and this value shows a good agreement with that given by the conventional method as well as the theoretical value. To compare the coupling loss factor, L-shape beam system which consists of a aluminum beam subsystem and a steel beam subsystem coupled by three pin is taken as second example. The input power and stored energy of each subsystem are found by the proposed approach. The coupling loss factor found by the electrical input power obtained from the piezoelectric actuator exhibits similar trend to the value found by the conventional method as well as the theoretical value. In conclusion, the use of SEA for high frequency application of piezoelectric smart structures is Possible. Especially, the input power that is essential for SEA can be found accurately by measuring the electrical input power of the piezoelectric actuator.

  • PDF

Experimental study on the correlation between measurement length and winding or twist pitch for magnetization loss occurring in CORC and TSTC

  • Ji-Kwang Lee;Jinwoo Han;Kyeongdal Choi;Woo-Seok Kim
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.4
    • /
    • pp.40-44
    • /
    • 2023
  • For high-temperature superconducting power applications that need large current capacity, a large current conductor manufactured using multiple superconducting tape is required. Conductors being studied for large currents capacity such as CORC, TSTC, and RACC have advantages and disadvantages, and in order to use these conductors in coil form and apply them to AC power devices, research on magnetization loss occurring in superconductors due to external magnetic fields is essential. To accurately measure magnetization loss in a conductor that is twisted by stacking straight conductors like TSTC, the correlation between the measuring system and the shape of the sample must be clearly known to accurately measure the loss. In this paper, we will confirm the difference in magnetization loss measurement values according to the correlation between the length of the pickup coil and the twist pitch of the sample in CORC and TSTC shapes, and review considerations for accurate magnetization loss measurement from the results.

Measurement of Stator Core Loss of an Induction Motor at Each Manufacturing Process

  • Jeong, Kwangyoung;Ren, Ziyan;Yoon, Heesung;Koh, Chang-Seop
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1309-1314
    • /
    • 2014
  • The measurement of stator core loss for an induction motor at each manufacturing process is carried out in this paper. Iron loss in the stator core of induction motor changes after each manufacturing process due to the mechanical stress, which can cause the deterioration of the magnetic performances. This paper proposes a new iron loss measuring system of the stator core in an induction motor, which can be applied to the case when the distribution of magnetic flux density is not uniform along the magnetic flux path. In the system, the iron loss is calculated based on the induced voltage of the B-search coil and exciting current.

The Study of Improvement in Reactor Thermal Power Measurement Method using KALMAN FILTER (KALMAN FILTER를 이용한 원자로 열출력측정 방법개선에 관한 고찰)

  • 정남교
    • Journal of the Korean Professional Engineers Association
    • /
    • v.30 no.5
    • /
    • pp.82-95
    • /
    • 1997
  • A Study of Improvement in Reactor Thermal Power Measurement Method using Kalman Filter. The objectives of the safety analysis of nuclear power plants are to maintain the surface temperature of fuel and fuel cladding within limit value in case of Loss of Coolant accident (LOCA) so that it ensures the safety and reliability of nuclear power plants. The new technique evaluating the reactor power and improvement of existing plant system increase the safety margin of nuclear power plant operation, and accordingly, economic effect will be anticipated. Hereby, 1 would like to introduce reactor power measurement method using Kalman filter that enables to calculate the reactor power more precisely combining the parameters, for example, turbine output as the 1 st stage pressure of high pressure turbine, and reactor power using energy equilibrium relation. It is expected that the new technique will enhance the accuracy of measurement of reactor power and maintain the reliability of nuclear power operation by increasing operational safety margin, and gain the economic benefit

  • PDF

Research for Installation and Operation of High Temperature Superconducting Cable System (고온 초전도 케이블 시스템 설치 밀 운전을 위한 연구)

  • Choi, Hyung-Sik;Sohn, Song-Ho;Hwang, Si-Dole
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.653-657
    • /
    • 2005
  • The commercial contract was made firstly in the world for one set of high temperature superconducting(HTS) cable system between buyer, Korea Electric Power Research Institute and seller, Sumitomo Electric Industries, Ltd. in August 2004. After fabrication, test and examination, the HTS cable system will be installed at the KEPRI's test field in Gochang, Jeonbuk province from the time of July 2005. KEPRI is preparing measurement and test facilities for field test of the HTS cable system and carrying out researches into the design and construction of superconducting cable test building, evaluation of cooling performance, measurement of AC loss, analysis of the quench phenomena due to excess current and means of linking the HTS cable system to the existing electric power supplying system. The constitution of, the method to install and the plan of test operation of the HTS cable system will be presented in this paper.

  • PDF

A PC-based instrumental system for fast measurement and analysis of power losses in DC-DC converter (DC-DC 컨버터의 고속 손실측정과 분석을 위한 PC 기반 계측시스템)

  • 안태영;주정규
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.6
    • /
    • pp.569-575
    • /
    • 2003
  • This paper present a new fully-automated PC-based instrumental system that could quickly measure and analyze the efficiency of switching power supplies for the entire operating range. In the proposed system, we applied an Indirect method for high-voltage low-current measurements and a direct method for low-voltage high-current measurements, in order to obtain a high accuracy with minimum equipment requirement. Compared to the conventional methods, the newly proposed system offers more accurate and much faster real-time assessment of the efficiency with minimum measurement error. The performance and accuracy of the proposed system are verified using a 50 W switching power supply intended for telecommunication applications.

Coordinated Wide-Area Regulation of Transmission System for Voltage Profile Improvement and Power Loss Reduction

  • Asadzadeh, Babak;Golshannavaz, Sajjad
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.5
    • /
    • pp.279-286
    • /
    • 2017
  • In this paper, an optimal approach for the wide-area regulation of control devices in a transmission network is proposed. In order to realize an improved voltage profile and reduced power loss, existing devices such as tap-changing transformers, synchronous machines, and capacitor banks should be controlled in a coordinated and on-line manner. It is well-understood that phasor measurement units in transmission substations allow the system operators to access the on-line loading and operation status of the network. Accordingly, this study proposes efficient software applications that can be employed in area operation centers. Thus, the implanted control devices can be regulated in an on-line and wide-area coordinated approach. In this process, efficient objective functions are devised for both voltage profile improvement and power loss reduction. Subsequently, sensitivity analysis is carried out to determine the best weighting factors for these objectives. Extensive numerical studies are conducted on an IEEE 14-bus test system and a real-world system named the Azarbayjan Regional Transmission Network. The obtained results are discussed in detail to highlight the promising improvements.

Total AC Loss by simultaneously applied AC transport current and AC external magnetic field in BSCCO Tape

  • Park Myungjin;Lim Hyoungwoo;Cha Gueesoo;Lee Jikwang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.4
    • /
    • pp.10-13
    • /
    • 2005
  • Transport current and magnetic field which is generated by transport current make AC current - AC mag-netic field condition(AC-AC condition) in AC power application system using HTS tape. Therefore, characteristics of AC loss under the AC-AC condition are necessary to estimate AC loss of power device with accuracy such as HTS transformer. In this paper, we researched transport current loss, magnetization loss by perpendicular magnetic field and total loss which is represented as summation of both losses under the AC-AC condition in single HTS tape. As a result, magnetization loss showed increasing behavior under 65mT and decreasing behavior upper 65mT by influence of transport current. Transport current loss was increased continuously through out whole measurement ranges in the AC-AC condition. Total loss in HTS tape was dominated entirely by magnetization loss.