• 제목/요약/키워드: power line signal

검색결과 641건 처리시간 0.032초

전력선 통신 채널 Data Base 구축을 위한 기본 연구 (A Fundamental Study for Establishment of Channel Data Base in Power-Line Communications)

  • 오휘명;김관호;이원태;이재조
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제52권2호
    • /
    • pp.107-111
    • /
    • 2003
  • In the power-line communication systems, there are many factors of noise and attenuation in the power-line channels, because they were designed for not the communication but the power transmission. Also the transfer function of the channels is highly changed with the topology and the load of the power-lines. To cope with these poor channel situation, channel modeling, one of the many studies in progress, is being studied hard. Channel modeling is essential to apply the active schemes to overcome the bad channel(e.g. modulation technique, channel coding, signal coupling & filtering, etc.) to the power-line communications. In this paper, we have realized the statistical model(this model is suggested as the channel modeling method for the power-line channels) that is combined the transfer function with the various noises. And we have compared and examined the results with the measured data. Also we have studied the plan which can effectively establish the channel data base for the channel information consisted of the parameters that are derived from this modeling, and we have studied the plan to utilize the data base.

송전선로용 디지털 고장점 표정장치에 관한 연구 (A Study on Digital Fault Locator for Transmission Line)

  • 이경민;박철원
    • 전기학회논문지P
    • /
    • 제64권4호
    • /
    • pp.291-296
    • /
    • 2015
  • Transmission line is exposed to a large area, and then faults are likely to occur than the other component of power system. When a fault occurs on a transmission line, fault locator helps fast recovery of power supply on power system. This paper deals with the design of a digital fault locator for improvement accuracy of the fault distance estimation and a fault occurrence position for transmission line. The algorithm of a fault locator uses a DC offset removal filter and DFT filter. The algorithm utilizes a fault data of GPS time synchronized. The computed fault information is transmitted to the other side substation through communication. The digital fault locator includes MPU module, ADPU module, SIU module, and a power module. The MMI firmware and software of the fault locator was implemented.

계란 크랙의 온라인 검출 (On-line Detection of Cracks in Eggshell)

  • 최완규;조한근;백진하;장영창;연광석;조성찬
    • Journal of Biosystems Engineering
    • /
    • 제24권3호
    • /
    • pp.253-258
    • /
    • 1999
  • This study was conducted to develop an automatic egg inspection system for detecting creaked eggs based on acoustic impulse response. This system includes a sound generator, a sound sensor with signal conditioner, and a computer. The sound generator that hit the sharp of the dull edges of an egg was constructed with a ceramic ball pendulum attached to a rotary type solenoid. The signal conditioner included a pre-amplifier and a digital signal processing (DSP) board. The parameters for distinguishing cracked and normal eggs were the area, the geometric centroid and the resonance frequency of power spectrum of the acoustic signal generated. An algorithm for on-line detection of the continuous transferring eggs was developed. The performance tests resulted with 91% success rate to separate cracked and normal eggs at the rate of 1 second per an egg.

  • PDF

진동신호 분석을 위한 On-Line 시스템 개발 (Developement of On-Line System for Vibration Signal Analysis)

  • 김언석;임성정;김영식;이영길;김재철;정찬수;정상진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.616-619
    • /
    • 1995
  • This paper describes developement of on-line system for vibration signal analysis. In the power system, the main reason of transformer fault is due to a large amount of current by a short-circuit and a ground-fault. The electromagnetic force caused by fault-current deforms transformer windings and results in vibration pattern change. Therefore if the continuous on-line vibration monitoring on transformer is performed, an incipient failure can be detected. The developed system is composed of data acquisition devices, user interface program, signal processing program, diagnosis and trend analysis program, self diagnosis program and communication program.

  • PDF

전력선을 이용한 음성전달 시스템 개발 (Development of Sound Transmitting System using Power Line)

  • 반용준;강민우;구경완;이명섭;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.1075-1079
    • /
    • 2002
  • This paper presents a result of sound transmitting system with power line communication technique, Sound transmitting system is a transmitter which transmits modulated audio signal to power to power line and receiver which is capable of detesting it with earphone or speaker. It has been evaluated with the frequency characteristics and spectrum analysis. And, from the result of evaluation on the developed system, we confirm the superior sound transmitting characteristics, and the possibility of application on a language laboratory.

  • PDF

전력선 통신환경에서의 구동회로 개선에 관한 연구 (A study on the improvement of Drive circuit in the Power Line Communication)

  • 임승하
    • 전자공학회논문지 IE
    • /
    • 제44권4호
    • /
    • pp.30-34
    • /
    • 2007
  • 전력선 통신에서는 전력을 공급하기 위해 설치된 전력선을 통신 매체로 사용하기 때문에 채널 환경이 열악하다고 할 수 있다. 본 논문에서는 원활한 통신을 위해 신호 감쇠를 저감하는 결합기를 적용한 gate 구동회로를 설계하였다. 결합기의 수신 동작과 송신 동작을 등가회로 해석하여 구동회로에 적합한 임피던스를 갖도록 설계하였다. 그 결과 전력선에 연결된 수 많은 전자 제품들의 상호 작용으로 인한 임피던스 변화에 대한 환경을 개선하여 전력선 통신에서의 BER(Bit Error Rate)을 45% 향상하여 더 원활한 통신을 할 수 있도록 하였다.

전력선을 이용한 음향전달 시스템의 구성 및 특성 분석 (Analysis of Sound Transmitting System using Power line Communication Technique)

  • 김호수;이명섭;구경완;한상옥
    • 조명전기설비학회논문지
    • /
    • 제18권3호
    • /
    • pp.128-134
    • /
    • 2004
  • 본 연구에서는 전력선통신 기술을 이용하여 전송주파수에 음성신호를 변조한 후 전력선으로 전송하고 전력선으로부터 수신 및 복조하여 변조된 음성신호를 검출하는 음향전달 시스템을 제작하였다. 제작된 시스템으로부터 변복조 및 주파수 특성을 분석하여, 어학실습 교육을 위한 용도로서의 활용 가능성을 평가하였다. 그 결과 전달된 음향 신호가 최적상태는 아니지만 어학실습 교육용으로 청취하기에 충분한 수준으로 판단되었다.

고속전철 주행시 이선에 따른 전원외란 현상 모델링 및 시뮬레이션 구현 (A Modeling and Simulation Implementation on the Power Line Disturbances by Loss of Contact for the High-Speed Railway Vehicle)

  • 김재문;김양수;장진영;김윤명
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1137-1142
    • /
    • 2008
  • In this paper, an effect on power conversion unit in high-speed railway vehicle by loss of contact between a catenary system and pantograph suppling electrical power to high-speed railway vehicle are investigated. One of the most important needs accompanied by increasing the speed of high-speed railway vehicle is reduced that arc phenomenon by loss of contact brings out EMI. in case of high-speed railway vehicle using electrical power, as comparison with diesel rolling stock, PLD(Power Line Disturbance) such as harmonic, transient voltage and current, EMI, dummy signal injection etc usually occur. To analysis the effect on loss of contact, it is necessary electrical modeling system between the contact line and the pantograph according to the loss of contact. Therefore analytical model of a contact line and a pantograph is constructed to simulate the behaviour of loss of contact. The reliability of the modeling system is verified by simulation implementation on kinds of loss of contact.

  • PDF

지중 전력선 통신채널의 특성 해석 (An Analysis of Characteristics of Underground Power line Communication Channel)

  • 엄기환;신재호;이승준
    • 대한전자공학회논문지TC
    • /
    • 제48권5호
    • /
    • pp.40-45
    • /
    • 2011
  • 본 논문에서는 광대역 지중 전력선 통신 모뎀 및 네트워크 기술개발을 위하여 실제측정을 통해 지중 전력선 통신채널의 특성을 해석하였다. 지중 배전선로의 길이 및 구조물에 따른 지중 배전선로의 광대역 전력선 통신채널의 감쇠 량을 측정하기 위해 신호발생기, 스펙트럼 분석기, 비접촉식 커플러 등을 이용하여 채널 측정 시스템을 구성하였다. 실증시험을 위해 시험선로 내 단일 선로로서 가장 긴 고압 선로 두 곳을 선택하고, 그 채널상의 노이즈 특성 및 신호감쇠 레벨을 측정하였다. 측정결과 통신성능을 매우 떨어뜨릴 수 있는 임펄스 노이즈가 존재하는 것을 확인하였으며, 장거리 선로의 경우 선로 길이에 의한 고주파 감쇠가 나타나는 것으로 확인하였다.

케이블 TV 전송선로의 특성 개선을 위한 접지방식 (Grounding method for Improving of the Characteristics on Cable TV Transmission Line)

  • 황종선;김영민;연제진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.37-40
    • /
    • 2002
  • Ground connection began by experimenting lightning with the use of a kite and it means electric appliances, communication equipments, measuring instruments and so on connecting the Earth in order to flow away overcharged electricity. There are two kinds of earth connection: Power Ground and Signal Ground. Power Ground is for preventing an electric shock and in general there's no current in the connector. However in an accident, there's a quick flow of electricity out to the Earth. Signal Ground is not only for the safety of appliances but also for the safety of equipment operation. This paper is about connection for noise and interference reduce in order to prevent wrong operation and distortion of signal in the electrical appliances which can take place in cable TV.

  • PDF