• Title/Summary/Keyword: power line signal

Search Result 642, Processing Time 0.033 seconds

Measurement and Analysis of Loss in Optical Directional Couplers

  • Leepila, R.;Jangsilp, R.;Noppanakeepong, S.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.484-487
    • /
    • 2004
  • Symmetric directional couplers are widely used in interferometers, switches, and various signal processing devices. Recently, several optical couplers using multimode fibers were reported, but these suffer from inefficient coupling of light into a branching fiber and/or low directivity. This paper presents the measurement and analysis of loss in the connection of optical fibers via the optical directional couplers. The functionality of the device is based on the principle that is symmetrical, the power in excited mode can be unambiguously directed into one of the output channel by varying and of its parameters. In this experiment, we measure the power of loss in the optical directional coupler at various radius of curvature. Before the measurement of loss in x-coupler, we polish the contact of the fiber surface in order that light can penetrate through another port. The results show that, when the radius of curvature is increased, the loss power is decreased and also approaches of the straight line case.

  • PDF

A study of the voltage monitoring system with dial-up telephones (전화선을 이용한 전압 감시 시스템에 관한 연구)

  • Son, Myeong-Su;Nam, Kung-Do;Song, Byong-Kwon;Yoon, Kap-Koo;Jang, Me-Hea
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.107-111
    • /
    • 1996
  • In this paper, the voltage monitoring system is designed to monitor the outage and voltage fluctuation by using a dial-up telephone. The master station receives tire outage signal-such as interruption and voltage sag etc. - from the remote in on-line of real-time. The SCC(Serial Communication Controller) is adapted to monitor voltages multiple clients(about 256 clients) simultaneously. The voltage fluctuation in a normal range shall be transmitted to the master station, at early morning the clients use the telephone less frequently. The operating system shall be "window 95" and the database is programmed in Visual-basic for a easy analysis of voltage fluctuation.

  • PDF

Power Factor Correction Method without Input Current Sensor (입력전류센서 없는 단상전력변환기의 역률개선 기법)

  • Jung, Young-Seok;Moon, Gun-Woo;Rho, Chung-Wook;Lee, Jun-Young;Youn, Myung-Joong
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.564-566
    • /
    • 1996
  • New simple control method of power factor correcting(PFC) boost convertor without instantaneous measurement of input current is proposed. Using the averaged model, the power factor correction scheme is presented. With the measurements of input voltage and output voltage, the control signal is generated to make the shape of the line current same as the input voltage. The validity of the controller is verified through the computer simulations.

  • PDF

A Study or the Improvement of Performance for High power EMC filter (대전력용 EMC대책 필터의 성능개선에 관한 연구)

  • 배대환;김동일;배재영
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2000.11a
    • /
    • pp.75-78
    • /
    • 2000
  • Since the most of malfunctions in the industrial equipment controlled by processors is occured by the Electrical Fast Transient(EFT), the International Electrotechnical Commission(IEC) prepared the dummy signal to test the immunity level of the equipments. In this paper. we designed a new EMC filter for power line in break-box, which is consist of the feed-through capacitor and ferrite materials with high permeability which was wound or inserted in the second layer of the power cable in order to increase common mode inductance. We have obtained a excellent insertion loss characteristics over wide frequency band from 100 KHz up to 6 GHz. It is expected that the new EMC filter could be effectively used for industrial, MIL, and medical equipments to reduce a malfunctions and be suitable for IEC 61000-4-4.

  • PDF

Feasibility study of low power active RFID system based on the ultrasonic frequency (초음파를 이용한 저전력 Active RFID시스템의 구현가능성에 관한 연구)

  • Yoon, Ki-Hun;Kwak, Chul-Hyun;Kim, Keon-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.430-432
    • /
    • 2007
  • This paper proposes the possibility of SonicID system which is the active RFID based on the ultrasonic spectrum instead of using radio frequency. For the feasibility study, various performance indexes are measured in terms of power consumption and signal path loss onto the frequencies of 40KHz, 433MHz, and 2.4GHz. In addition to the line of sight condition, realistic situations are considered for diverse deploying environments. The results of these analyses demonstrate that the SonicID holds the potential to meet the needs of future advanced RFID system in a scalable fashion.

  • PDF

HPF Application Test for PD Detection of XLPE Power Cable (XLPE 전력케이블의 부분방전 검출을 위한 HPF 적용 시험)

  • Kim, Jung-Yoon;Yang, Jong-Kyung;Park, Noh-Joon;Choi, Yong-Sung;Park, Dae-Hee;Lee, Yong-Sung
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.4
    • /
    • pp.161-165
    • /
    • 2006
  • In this paper, we developed HPF (high pass filter) consists of lumped LC components to decrease the noises that are detected in PD (partial discharge) measuring test, and adapted it to field test. We tested it under laboratory circumstances like the fields, and measured the phase change properties of detected signal in UHF sensor with Lemke Probe and oscilloscope (TDS-3054, Tektronix). As a result, we obtained available data showing the decrease of noises in the experiments with the developed HPF from the joint box of 22.9kV distribution line. The result can be adapted to prevent the degeneration of the XLPE power cable, and to observe and diagnosis the underground power transmission cable at the ultra-high voltage.

On-line Estimation of Low Frequency Osillation Mode Using Prony Analysis in the Power System (PRONY 해석을 사용한 전력계통 저주파 전동모드의 온라인 추정)

  • Lee, K.Y.;Shim, K.S.;Nam, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.167-170
    • /
    • 2002
  • This paper presents a mode estimation for the analysis of small signal stability in power system. The low frequency oscillation mode estimation is based on Prony method that is able to accurately compute the modal parameters (frequency and damping) of oscillation mode from time series. The time series or time domain data is obtained in TSA process. The method applied to a large scale power systems and compared on the eigenanalysis results.

  • PDF

Zinc Loss Detection in ACSR Power Lines using the Removable Type of Eddy Current Sensor (착탈형 와류센서를 이용한 ACSR전선의 아연손실량 검출)

  • Jang, T.I.;Jo, S.B.;Kang, J.W.;Kang, Y.W.;Yang, B.M.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1963-1965
    • /
    • 2000
  • This paper deals with a problem of detecting the inner corrosion of the ACSR(Aluminum Conductor Steel Reinforced) power lines using a detector which consists of an ECT(Eddy Current Test) sensor, a constant current service, a signal processing unit, and a RF transmitter/receiver unit. The detector runs on the ACSR transmission line and inspects the corrosion of the conductor using the technic of the nondestructive eddy current test. The experimental result shows this detector can efficiently find the zinc loss in ACSR power lines.

  • PDF

Comparison of Two Layout Options for 110-GHz CMOS LC Cross-Coupled Oscillators

  • Kim, Doyoon;Rieh, Jae-Sung
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.2
    • /
    • pp.141-143
    • /
    • 2018
  • Two 110-GHz oscillators have been developed in 65-nm CMOS technology. To study the effect of layout on the circuit performance, both oscillators had the same LC cross-coupled topology but different layout schemes of the circuit. The oscillator with the conventional cross-coupled design (OSC1), showed an output power of -3.9 dBm at 111 GHz with a phase noise of -75 dBc/Hz at 1-MHz offset. On the other hand, OSC2, with a modified cross-coupled line layout, generated an output power of -2.0 dBm at 117 GHz with a phase noise of -77 dBc/Hz at 1-MHz offset. The result indicates that the optimized layout can improve key oscillator performances such as oscillation frequency and output power.

Filter Design for Fault Location Detection on Underground Power Cable (지중송전케이블 고장신호 처리를 위한 필터 설계)

  • Lee, Jae-Duck;Ryoo, Hee-Suk;Choi, Sang-Bong;Nam, Kee-Young;Jeong, Seong-Hwan;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.361-363
    • /
    • 2003
  • To reduce the effect of fault on underground power cable, we need exact and fast fault location detection technique. In this thesis, we describe on filter design technique that can be applied to on-line fault defection technique. To design fitter for fault location defection on Power cable, we should analysis fault signal. So we designed test bed for fault generation and measured fault signals for analysis. Through the analysis of signals, we found that ANC filter can be applied to separate fault signals and we designed a ANC filter. We tested on the designed filter through computer simulation, and we describe its results in this paper.

  • PDF