• Title/Summary/Keyword: power line environment

Search Result 359, Processing Time 0.039 seconds

Grid faults characteristics simulation of inverter-fed induction generator (인버터 부착형 농형 유도발전기의 계통고장특성 모의)

  • Hong, Jitae;Kwon, Soonman;Kim, Chunkyung;Lee, Jongmoo;Cheon, Jongmin;Kim, Hong-Ju;Kim, Heeje
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.43.1-43.1
    • /
    • 2011
  • The detail simulation modeling of fully-fed induction generator is investigated through PC based MATLAB/Simulink environment. Generator's stator currents are controlled by indirect vector control method. In this method, generator side converter controls the maximum excitation (air gap flux) by stator d-axis current and controls generator torque by stator q-axis current. Induction generator speed is controlled by tip speed ratio (TSR) upon the wind speed variations in order to generate the maximum output power. The generator torque model is specified as a 3-blade wind turbine with rating, then, the model is simulated under normal operating condition and three different fault conditions. The matlab model designed for fully-fed induction generator based wind farm provides good performance under normal and grid fault conditions. It provides good results for different pwm techniques and fault conditions except the single-phase line to ground fault, which should be verified with real time data from wind farms.

  • PDF

Transmission Characteristics of Indoor Infrared Diffuse Links Employing Three-Beam Optical Transmitters and Non-Imaging Receivers

  • Wang, Zan;Pan, Jae-Kyung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.12A
    • /
    • pp.1251-1260
    • /
    • 2008
  • Diffuse wireless optical communication offers more robust optical links in terms of coverage and shadowing than line-of-sight links. However, traditional diffuse wireless infrared (IR) transceiver systems are more susceptible to multi-path distortion and great power decrease, which results in limiting high-speed performance. Multi-beam is an effective technique to compensate for multi-path distortion in a wireless infrared environment. The goal of this paper is to analyze the transmission characteristics by replacing traditional diffuse system (TDS) which contains single wide angle transmitter and single element receiver by system consisting of three-beam transmitter and non-imaging receiver (TNS) attached with compound parabolic concentrator (CPC). In the simulation, we use the recursive model developed by Barry and Kahn and build the scenario based on 10 different cases which have been listed in Table 1. Moreover, we also check the reliability of the TNS diffuse link channel by BER test on the basis of different receiver positions and room sizes. The simulation results not only show the basic transmission characteristics of TNS diffuse link, but also are references to design more efficient and reliable indoor infrared transmission systems.

Modified Gram-Schmidt Algorithm Using Equivalent Wiener-Hopf Equation (등가의 Wiener-Hopf 방정식을 이용한 수정된 Gram-Schmidt 알고리즘)

  • Ahn, Bong-Man;Hwang, Jee-Won;Cho, Ju-Phil
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.7C
    • /
    • pp.562-568
    • /
    • 2008
  • This paper proposes the scheme which obtain the coefficients of TDL filter and two normalization algorithms among methods which get solution of equivalent Wiener-Hopf Equation in Gram-Schmidt algorithm. Compared to the conventional NLMS algorithm, normalizes with sum of power of inputs, the presented algorithms normalize using sums of eigenvalues. Using computer simulation, we perform an system identification in an unstable environment where two poles are located in near position outside unit circle. Consequently, the proposed algorithms get the coefficients of TDL filter in Gram-Schmidt algorithm recursively and show better convergence performance than conventional NLMS algorithm.

A Study on the Illegal Copy Prevention and Tracking for Copyright Protection in Power Line Communication Home Networking Environment (PLC 홈 네트워킹 환경에서 저작권 보호를 위한 불법 복제 방지 및 추적에 관한 연구)

  • Seo, In-Hye;Lee, Yang-Sun;Kang, Heau-Jo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.221-224
    • /
    • 2005
  • 본 논문에서는 워터마크가 삽입된 데이터의 저작권 보호를 위하여 데이터의 복제 시 신속한 위치추적을 통한 불법 복제 방지 시스템을 제안하고 시뮬레이션 하였다. 제안된 방법은 복사기, 프린터, 스캐너 등에 부착된 워터마크 검출 장치로부터 워터마크 검출 시 원 워터마크 이미지와 추출된 워터마크이미지가 일정 비 이상의 상관관계가 있을 경우 불법 복제 상황으로 간주하고, 디지털 데이터로 변환된 워터마크 이미지와 주소 정보가 전력선을 통하여 전송된다. 수신단에서는 수신된 데이터의 발신자 정보를 통해 위치정보를 알아내어 불법 복제 작업현장의 위치를 추적한다. 전력선을 통신선로로 이용 시 전송신호는 전력선 채널 환경에서 임펄스 잡음에 많은 영향을 받기 때문에 본 논문에서는 제안한 시스템의 검증을 위해 AWGN과 임펄스 잡음을 고려하고 잡음 특성이 우수하고 신뢰성이 비교적 강한 DS-CDMA/BPSK 시스템을 통해 제안된 시스템을 시뮬레이션 하였다. 또한, 열악한 채널 환경으로부터 수신성능을 개선하기 위해 컨벌루션 부호화기법을 적용하여 성능 개선 전 후의 복원 이미지의 성능을 비교 분석 하였다.

  • PDF

Reliability Assesment of 22.9kV High Temperature Superconducting Cable System (22.9kV 초전도케이블 시스템의 신뢰성 평가)

  • Sohn, Song-Ho;Lim, Ji-Hyun;Sung, Tae-Hyun;Ryoo, Hee-Suk;Yang, Hyung-Suk;Kim, Dong-Lak;Hwang, Si-Dole
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.248-248
    • /
    • 2007
  • Demands for electricity are growing, whereas the rate of electricity infrastructure's construction declines gradually. To keep the balance of the demand and supply, the share of underground transmission line will be increased from 8.3% to 10.5% in 2020 but it will be accompanied with enormous public expenses. A great concern in high capacity transmission is on the increase so as to maximize the spacial efficiency. High Temperature Superconducting (HTS) cable is in the lime light which has the merits of environment-friendly, low transmission loss and high transmission with low voltage, but the reliability verification as a power system is yet to be solved. KEPCO completed the installation and acceptance of $3{\phi}$, 22.9kV, 1250A class HTS cable system in 2006 and the long term test is in progress. The test results focusing on long term reliability are presented in this paper.

  • PDF

Development of Arm Insulator for Self-Build Based Emergency Tower (긴급복구용 자주조립식 철주 절연암 개발)

  • Min, Byeong-Wook;Wi, Hwa-Bog;Park, Jae-Ung;Lee, Cheol-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.107-108
    • /
    • 2007
  • Overhead transmission lines are completely exposed to the environment. This causes faults in transmission lines due to natural environmental conditions. In some cases, transmission towers are damaged by typhoons and snow, as well as sleet on the transmission lines. It takes a lot of time to repair the damaged towers. For emergency restoration purposes, steel poles are installed to temporarily supply power. Before 2003, emergency restoration steel poles were made of angled steel, which required a large number of beams, bolts, etc. In addition, the foundation of the steel pole and ground wire was constructed using excavation and burial methods, therefore it required a lot of manpower and time to construct temporary transmission lines. In September 2003, typhoon Maemi, whose maximum wind speed was 60m/s, hit Korea. 'Maemi' destroyed transmission lines in the Busan and Geojea area, causing long blackouts. To reduce the recovery time to the damaged transmission lines, self-build based emergency towers were developed. self-build based emergency towers reduced recovery time from 24 hours to 4 hours or less. However, the self-build based emergency tower had no arms, so the temporary transmission lines could only be constructed without curves in line routes. In this paper, solving these self-build based emergency tower limitations, using insulated arms(designed for use with the self-build based emergency tower), shall be explained.

  • PDF

Research on Insulation Design of the Bushing for a 154kV Class HTS Transformer (154kV급 고온초전도 변압기용 부싱의 절연설계에 관한 연구)

  • Kwag, D.S.;Cheon, H.G.;Choi, J.H.;Kim, H.J.;Yun, M.S.;Kim, Y.S.;Kim, S.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.216-217
    • /
    • 2006
  • A common problem in many fields of cryogenic power engineering is to apply high voltage to cold parts of superconducting equipment. In many of these cases a bushing provides electrical insulation for the conductor which makes the transition from ambient temperature to the cold environment. The cryogenic high voltage bushing for the 154kV, 100MVA high temperature superconducting(HTS) transformer is described. The bushing is energized with the line-to-ground voltage between the coaxial center and outer surrounding conductors, in the axial direction there is a temperature difference from ambient to about 77 K. For the insulation design of cryogenic bushing, the arrangement of condenser cone and electrical insulation characteristics of GFRP, Air, $LN_2$ and $GN_2$ were discussed in this paper.

  • PDF

The Development of Third-Rail System Applied to Turn-out Section for Urban Maglev (도시형 자기부상열차 분기기 구간의 제3궤조 전차선 시스템 개발)

  • Min, Byong-Chan;Heo, Young-Tae;Hong, Du-Young;Lee, Won-Joo;Jo, Su-Yeon;Jeong, Nam-Cheol
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.3046-3051
    • /
    • 2011
  • The third-rail system is an important device supplying power directly to the Maglev train through physical contact with the collecting shoe. It is directly related to safety and reliability for the running of Maglev. However, most the third-rail system used in Korea depend on foreign product or technologies, Korea Urban Maglev in the development of appropriate power feeding is urgent. In particular, the turnout section is the weakness point in the system because bending force by turnout section movement and fatigue caused by repetitive motion as well as the expansion by temperature, the forces by Maglev collecting shoe is added th the third-rail. Therefore, this paper proposes the third-rail system appropriate for Korean Urban Maglev of turnout section. To verify the structural stability of POSCO ICT third-rail system, the finite element analysis and physical testing was performed. The third-rail is fixed on each side of the turn-out section steel structure by epoxy insulation supporter and the integral behaviors are occurred. Therefore, the maximum horizontal displacements of each support are investigated and then, it is applied to finite element model of the third-rail to investigate the moments and stress. Also, the bending test about one million times and Expansion Joint for the third-rail was performed. The third-rail system safety and reliability was identified by test line on Korea Institute of Machinery & Materials in Deajeon for under the actual usage environment such as the Maglev and turn-out operation.

  • PDF

Weighted Optimal Location of Mail Distribution Center Using GOSST (GOSST를 이용한우편물 교환센터의 가중치 반영 최적 위치의 선정)

  • Kim, In-Bum;Kim, Joon-Mo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.11
    • /
    • pp.7-13
    • /
    • 2010
  • For swiftness and economic feasibility of parcel delivery, optimal location of mail exchanging centers considering not only section delivery distance but also some weights like the number of delivery vehicles are necessary. In this paper, a mechanism with section delivery distance and vehicle number for locating of mail distribution centers which connect some mail centers of major cities in Republic Korea by applying GOSST theory is proposed. This mechanism for locating mail exchange centers can make the total delivery distance of postal matters less than not only present method which assigns Daejun as mail exchange center, but also Steiner tree method which does not consider weights like number of delivery vehicles. The mechanism is good for protecting the environment as well as rapid and economic delivery. In experiment, the proposed mechanism could curtail total delivery distance by 2.52 percentages compared with Steiner tree method and by 6.66 percentages compared with present method. The mechanism may be used in electric power transmission routing, distribution line topology design, power relay station locating where various voltages and other weights should be considered.

Design and Implementation of Ontology-Based Natural Language Search System (온톨로지 기반의 자연어 검색 시스템 설계 및 구현)

  • Kang, Rae-Goo;Lim, Dong-Il;Jung, Chai-Yeoung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.875-878
    • /
    • 2007
  • Up until now, when a user search product information, the keyword-based search that mainly uses frequency of words or vocabulary information has been utilized in large. In the keyword-based research, the user should have to bear additional burden in order to search the displayed results manually once again because it shows those files that have no connection at all with the inquiries made by the user. To resolve such a problem, ontology has been emerged. In this paper, product search system using ontology was constructed directly and also tested how accurate search it does perform through the searching according to classification. To test this, about 40,000 product data of A discount store, which was operating on/off line discount stores, were constructed as database, and developmental environment for User Interface was tested by having developed the search system using JSP and PowerBuilder 9.0. Results from the test proved that the search method using Domain Ontology for product presented and designed in this paper was superior to the existing keyword-based search method.

  • PDF