• Title/Summary/Keyword: power integrity characteristics

Search Result 104, Processing Time 0.027 seconds

Analysis of Pipe Wall-thinning Caused by Water Chemistry Change in Secondary System of Nuclear Power Plant (원전 2차계통의 수화학 변화가 배관감육에 미치는 영향 분석)

  • Yun, Hun;Hwang, Kyeongmo;Moon, Seung-Jae
    • Corrosion Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.325-330
    • /
    • 2015
  • Pipe wall-thinning by flow-accelerated corrosion (FAC) is a significant and costly damage of secondary system piping in nuclear power plants (NPPs). All NPPs have their management programs to ensure pipe integrity from wall-thinning. This study analyzed the pipe wall-thinning caused by changing the amine, which is used for adjusting the water chemistry in the secondary system of NPPs. The pH change was analyzed according to the addition of amine. Then, the wear rate calculated in two different amines was compared at the steam cycle in NPPs. As a result, increasing the pH at operating temperature (Hot pH) can reduce the rate of FAC damage significantly. Wall-thinning is affected by amine characteristics depending on temperature and quality of water.

The Effect of Empowering Leadership on Employee's Work Engagement and Job Satisfaction: Moderating Effect of Behavioral Integrity (임파워링 리더십이 조직구성원의 직무열의와 직무만족에 미치는 영향: 행동적 진실성의 조절효과를 중심으로)

  • Ko, Min Jeong;Hah, Juhee
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.15 no.4
    • /
    • pp.217-230
    • /
    • 2020
  • In a view of rapidly changing business environment, the success and competing power of organizations depend on committed, highly motivated and satisfied human resources. Empowerment is mainly concerned with establishing and building trust between management and employees, and motivating their participation. Also, behavioral integrity emphasizing on the characteristics of effective leaders has shown as direct action that strengthens positive consequences in organizations. However, research regarding behavioral integrity is very limited. Based on the Self-determination Theory, this paper investigates the effect of empowering leadership on employee's job satisfaction and work engagement. Multi-group analysis based on behavioral integrity is also analyzed. An online survey was conducted and 298 employees' data were collected. Using structural equation modeling, results suggest as follows. First, empowering leadership had a positive effect on individual's job satisfaction mediated by their work engagement. Second, the result of the multi-group analysis showed that the effect of empowering leadership on work engagement is stronger in the group with high behavioral integrity. Contrary to the prediction, the result doesn't support the moderating effect on job satisfaction. These findings contribute to our understanding of empowering leadership process. Based on the results, several theoretical and managerial implications are discussed.

Numerical Analysis on the Transient Load Characteristics of Supersonic Steam Impinging Jet using LES Turbulence Model (LES 난류모델을 이용한 초음속 증기 충돌제트의 과도하중 특성에 대한 수치해석 연구)

  • Oh, Se-Hong;Choi, Dae Kyung;Park, Won Man;Kim, Won Tae;Chang, Yoon-Suk;Choi, Choengryul
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.14 no.2
    • /
    • pp.77-87
    • /
    • 2018
  • In the case of high-energy line breaks in nuclear power plants, supersonic steam jet is formed due to the rapid depressurization. The steam jet can cause impingement load on the adjacent structures, piping systems and components. In order to secure the design integrity of the nuclear power plant, it is necessary to evaluate the load characteristics of the steam jet generated by high-energy pipe rupture. In the design process of nuclear power plant, jet impingement load evaluation was usually performed based on ANSI/ANS 58.2. However, U.S. NRC recently pointed out that ANSI/ANS 58.2 oversimplifies the jet behavior and that some assumptions are non-conservative. In addition, it is recommended that dynamic analysis techniques should be applied to consider transient load characteristics. Therefore, it is necessary to establish an evaluation methodology that can analyze the dynamic load characteristics of steam jet ejected when high energy pipe breaks. This research group has developed and validated the CFD analysis methodology to evaluate the transient behavior of supersonic impinging jet in the previous study. In this study, numerical study on the transient load characteristics of supersonic steam jet impingement was carried out and amplitude and frequency analysis of transient jet load was performed.

Security Model for Tree-based Routing in Wireless Sensor Networks: Structure and Evaluation

  • Almomani, Iman;Saadeh, Maha
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.4
    • /
    • pp.1223-1247
    • /
    • 2012
  • The need for securing Wireless Sensor Networks (WSNs) is essential especially in mission critical fields such as military and medical applications. Security techniques that are used to secure any network depend on the security requirements that should be achieved to protect the network from different types of attacks. Furthermore, the characteristics of wireless networks should be taken into consideration when applying security techniques to these networks. In this paper, energy efficient Security Model for Tree-based Routing protocols (SMTR) is proposed. In SMTR, different attacks that could face any tree-based routing protocol in WSNs are studied to design a security reference model that achieves authentication and data integrity using either Message Authentication Code (MAC) or Digital Signature (DS) techniques. The SMTR communication and processing costs are mathematically analyzed. Moreover, SMTR evaluation is performed by firstly, evaluating several MAC and DS techniques by applying them to tree-based routing protocol and assess their efficiency in terms of their power requirements. Secondly, the results of this assessment are utilized to evaluate SMTR phases in terms of energy saving, packet delivery success ratio and network life time.

Damage Evaluation of Porcelain Insulators Using the Frequency Response Function (주파수응답함수(FRF)를 이용한 자기 애자의 손상평가)

  • Choi, In-Hyuk;Son, Ju-Am;Oh, Tae-Keun;Yoon, Young-Geun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.2
    • /
    • pp.122-128
    • /
    • 2019
  • Porcelain insulators have been used mainly for power line fixing and electrical insulation in transmission towers. Porcelain insulators have generally a 30 years desired life, but over 50% exceed their life expectancy. Since the damage to porcelain insulators is usually accompanied by enormous loss of human resource material, their efficient maintenance has emerged as an important issue. In this regard, this study applied a frequency response function (FRF) for integrity assessment of the insulator. The characteristics of the FRF according to damage types were identified and analyzed by the change in natural frequencies, curve shape, attenuation, and Nyquist diagram stability. The results showed significant differences in the FRF according to damage types, which can be used as basic data for the effective integrity assessment of porcelain insulators.

중국(中國)의 청루문화(靑樓文化) 고찰

  • Song, Gyeong-Ae
    • 중국학논총
    • /
    • no.62
    • /
    • pp.71-84
    • /
    • 2019
  • Brothel in China is another word of origin and a noble expression at the same time. Brothel has long been used as a symbol of prestige and wealth as a synonym for integrity innocence. According to documentary records, brothel was used as a place where people with a lot of power and wealth. This meaning in the literature continued until the Late Tang period. In addition, the brothel was also used to refer to the place where the King resides. Therefore, the meaning of Brothel in the Tang period is generally understood as a place where people with high status symbolize the integrity of innocence. However, the image of the brothel, which is connected to the characteristics of a lot of young and beautiful women is increasingly recognized as a place where young ladies reside. For this reason, entering the Tang period the brothel eventually turned into a dwelling of a young woman in a prestigious and wealthy house. Since the time of Ming-Qing, brothel has already been used to refer to prostitute and brothel. In this article, we will look at the historical process of the change of brothel, and examine the process of brothel culture through the environment of brothel and cultural literacy of residents. We hope that this study will provide new perspectives and data to the study of women's cultural history in China.

Activities to attain integrity of generator current transformer (발전기 변류기 건전성 확보를 위한 연구)

  • Cho, C.W.;Cho, S.T.;Yang, K.H.;Ann, K.J.;Lee, H.Y.
    • Journal of Power System Engineering
    • /
    • v.16 no.1
    • /
    • pp.19-23
    • /
    • 2012
  • This thesis is the result of conducting an analysis to find the solution to the phenomenon of power stoppage due to the disconnection of a CT (Current Transformer) because of vibration. The CT which measures the most essential current is used in power industries as part of a generator protection relay. When it comes to the bottom plate of a CT, nonconductor; such as bakelite and laminates; these material elements should be used because it is impossible to utilize the conductor when measuring the current of a generator which carries a high current if you use other materials. These nonconductor's material properties are irregular and interpretation errors often occur because the weight is light. In addition, since the change of dynamic characteristics which are related to the temperature often occur, it is important to match the real situation by considering an error of interpretation rather than selecting the quality of the material. Lastly, the conclusion that the study drew is that it is possible to avoid the resonance by utilizing three changes to the components to solve the problem concerning the high vibration which is caused by non-conductive objects. These changes are the most crucial points in this thesis: First, material changes to the Plate. Second, weight changes to the Coil. Third, thickness changes to the Plate.

Development of Wall-Thinning Evaluation Procedure for Nuclear Power Plant Piping-Part 1: Quantification of Thickness Measurement Deviation

  • Yun, Hun;Moon, Seung-Jae;Oh, Young-Jin
    • Nuclear Engineering and Technology
    • /
    • v.48 no.3
    • /
    • pp.820-830
    • /
    • 2016
  • Pipe wall thinning by flow-accelerated corrosion and various types of erosion is a significant and costly damage phenomenon in secondary piping systems of nuclear power plants (NPPs). Most NPPs have management programs to ensure pipe integrity due to wall thinning that includes periodic measurements for pipe wall thicknesses using nondestructive evaluation techniques. Numerous measurements using ultrasonic tests (UTs; one of the nondestructive evaluation technologies) have been performed during scheduled outages in NPPs. Using the thickness measurement data, wall thinning rates of each component are determined conservatively according to several evaluation methods developed by the United States Electric Power Research Institute. However, little is known about the conservativeness or reliability of the evaluation methods because of a lack of understanding of the measurement error. In this study, quantitative models for UT thickness measurement deviations of nuclear pipes and fittings were developed as the first step for establishing an optimized thinning evaluation procedure considering measurement error. In order to understand the characteristics of UT thickness measurement errors of nuclear pipes and fittings, round robin test results, which were obtained by previous researchers under laboratory conditions, were analyzed. Then, based on a large dataset of actual plant data from four NPPs, a quantitative model for UT thickness measurement deviation is proposed for plant conditions.

Dynamic Characteristics of the Integral Reactor SMART

  • Kim, Tae-Wan;Park, Keun-Bae;Jeong, Kyeong-Hoon;Lee, Gyu-Mahn;Park, Suhn
    • Nuclear Engineering and Technology
    • /
    • v.33 no.1
    • /
    • pp.111-120
    • /
    • 2001
  • In this study, a dynamic analysis of the integral reactor SMART (System-integrated Modular Advanced ReacTor) under postulated seismic events is performed to review the response characteristics of the major components. To enhance the feasibility of an analysis model, a detailed finite element model is synchronized with the products of concurrent design activities. The artificial time history, which has been applied to the seismic analysis for the Korean Standard Nuclear Power Plant (KSNP), is chosen to envelop broad site specifics in Korea. Responses in the horizontal direction are found slightly amplified, while those in the vertical direction are suppressed. Since amplified response is monitored at the control element drive mechanism (CEDM), minor design provision is considered to enhance the integrity of the subsystem.

  • PDF

Dynamic response of a fuel assembly for a KSNP design earthquake

  • Jhung, Myung Jo;Choi, Youngin;Oh, Changsik
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3353-3360
    • /
    • 2022
  • Using data from the design earthquake of the Korean standard nuclear power plant, seismic analyses of a fuel assembly are conducted in this study. The modal characteristics are used to develop an input deck for the seismic analysis. With a time history analysis, the responses of the fuel assembly in the event of an earthquake are obtained. In particular, the displacement, velocity, and acceleration responses at the center location of the fuel assembly are obtained in the time domain, with these outcomes then used for a detailed structural analysis of the fuel rods in the ensuing analyses. The response spectra are also generated to determine the response characteristics in the frequency domain. The structural integrity of the fuel assembly can be ensured through this type of time history analysis considering the input excitations of various earthquakes considered in the design.