• Title/Summary/Keyword: power inductor

Search Result 998, Processing Time 0.023 seconds

A New Valley-fill Circuit for Improving Power Factor (밸리-필 정류 회로의 역률 개선)

  • 최남열;안찬권;이치환
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2935-2938
    • /
    • 2003
  • A new Valley-fill circuit for improving PF(power factor) is proposed in this paper. The proposed topology combines Valley-fill rectifier and an additional inductor for boosting. In the proposed circuit, a shapc of input current is related to the PWM duty cycle. The boosting inductor makes improve PF by the electric charge transfer action. The operation principle and the shape of input current arc analyzed as applied the boosting inductor. The optimum value of boosting inductor is determined. A 100W single-stage converter has been designed and tested. Experimental results are presented to verify the validity of the proposed converter.

  • PDF

A Study on the Selection of Parameter for the Optimal Inductor Design using Fuzzy Theory (퍼지이론을 적용한 최적 인덕터 설계 파라미터 선정에 관한 연구)

  • 윤창선;배동관;김광헌;이재신;김병철
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.58-61
    • /
    • 1999
  • This paper describes the program of optimally choosing parameter in designing inductor, which applied by fuzzy theory, and verifies the reliability of program to use in design of power supply of electronic machine and information communication. It is available to find optimal value of complex and various parameter, such as core, winding, winding number, and air-gap, etc., needed on designing inductor. We expects to minimize time and cost of inductor design.

  • PDF

Dual-Coupled Inductor High Gain DC/DC Converter with Ripple Absorption Circuit

  • Yang, Jie;Yu, Dongsheng;Alkahtani, Mohammed;Yuan, Ligen;Zhou, Zhi;Zhu, Hong;Chiemeka, Maxwell
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1366-1379
    • /
    • 2019
  • High-gain DC/DC converters have become one of the key technologies for the grid-connected operation of new energy power generation, and its research provides a significant impetus for the rapid development of new energy power generation. Inspired by the transformer effect and the ripple-suppressed ability of a coupled inductor, a double-coupled inductor high gain DC/DC converter with a ripple absorption circuit is proposed in this paper. By integrating the diode-capacitor voltage multiplying unit into the quadratic Boost converter and assembling the independent inductor into the magnetic core of structure coupled inductors, the adjustable range of the voltage gain can be effectively extended and the limit on duty ratio can be avoided. In addition, the volume of the magnetic element can be reduced. Very small ripples of input current can be obtained by the ripple absorption circuit, which is composed of an auxiliary inductor and a capacitor. The leakage inductance loss can be recovered to the load in a switching period, and the switching-off voltage spikes caused by leakage inductance can be suppressed by absorption in the diode-capacitor voltage multiplying unit. On the basis of the theoretical analysis, the feasibility of the proposed converter is verified by test results obtained by simulations and an experimental prototype.

Coupled Inductor Based Voltage Balancing in Dual-Output CLL Resonant Converter for Bipolar DC Distribution System (양극성 DC 배전 시스템 적용을 위한 결합 인덕터 기반의 전압 밸런싱 이중 출력 CLL 공진형 컨버터)

  • Lee, Seunghoon;Kim, Jeonghun;Cha, Honnyong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.4
    • /
    • pp.348-355
    • /
    • 2022
  • A bipolar DC distribution system suffers from an imbalance in voltages when asymmetric loads are connected at the outputs. Dedicated voltage balancers are required to address the imbalance in bipolar voltage levels. However, additional components eventually increase the cost and decrease the efficiency and power density of the system. Therefore, to deal with the imbalance in output voltages without adding any extra components, this study presents a coupled inductor-based voltage balancing technique with a dual-output CLL resonant converter. The proposed coupled inductor does not require extra magnetic components to balance the output voltages because it is the result of resonant inductors of the CLL tank circuit. It can also avoid complex control schemes applied to voltage balancing. Moreover, with the proposed coupled inductor, the CLL converter acquires good features including zero voltage and zero current switching. Detailed analysis of the proposed coupled inductor is presented with different load conditions. A 3.6-kW hardware prototype was built and tested to validate the performance of the proposed coupled inductor-based voltage balancing technique.

Three-Level Zeta Converter using a Coupled Inductor (결합 인덕터를 이용한 3-레벨 Zeta 컨버터)

  • Lee, Seung-Jae;Yang, Min-Kwon;Heo, Jun;Choi, Woo-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.3
    • /
    • pp.191-199
    • /
    • 2016
  • Conventional two-level Zeta converters have drawbacks, such as high voltage stresses and high current ripples. To address these problems, a three-level Zeta converter that uses a couple inductor is proposed in this study. The proposed converter utilizes the three-level power switching circuit to reduce the voltage stresses and inductor current ripples. Compared with the conventional converter, the proposed converter can improve power efficiency and power density. A 500 W prototype circuit is used to verify the operation and performance of the proposed converter via experimental results.

Time-Delay Effects on DC Characteristics of Peak Current Controlled Power LED Drivers

  • Jung, Young-Seok;Kim, Marn-Go
    • Journal of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.715-722
    • /
    • 2012
  • New discrete time domain models for the peak current controlled (PCC) power LED drivers in continuous conduction mode include for the first time the effects of the time delay in the pulse-width-modulator. Realistic amounts of time delay are found to have significant effects on the average output LED current and on the critical inductor value at the boundary between the two conduction modes. Especially, the time delay can provide an accurate LED current for the PCC buck converter with a wide input voltage. The models can also predict the critical inductor value at the mode boundary as functions of the input voltage and the time delay. The overshoot of the peak inductor current due to the time delay results in the increase of the average output current and the reduction of the critical inductor value at the mode boundary in all converters. Experimental results are presented for the PCC buck LED driver with constant-frequency controller.

Output Inductor Less Phase Shift Full Bridge Converter with Current Stress Reduction Technique for Server Power Application

  • Lee, Woo-Jin;Park, Ki-Bum;Heo, Tae-Won;Moon, Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.502-504
    • /
    • 2008
  • A new output inductor less phase shift full bridge converter with current reduction technique for server power application is proposed in this paper. The proposed converter can reduce the current stress by using the auxiliary circuit. Since the auxiliary circuit causes the additional resonance between the leakage inductor and auxiliary capacitor before the powering period, the proposed converter has lower current stress even no output filter inductor. Small size and circulating energy can be also the merits of the proposed converter. The operational principles and analysis are presented. Experimental results demonstrate that the current stress can be reduced effectively by using the auxiliary circuit without large output filter inductor.

  • PDF

Droop Method for High-Capacity Parallel Inverters in Islanded Mode Using Virtual Inductor (독립운전 모드에서 가상 인덕터를 활용한 대용량 인버터 병렬운전을 위한 드룹제어)

  • Jung, Kyo-Sun;Lim, Kyung-Bae;Kim, Dong-Hwan;Choi, Jaeho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.1
    • /
    • pp.81-90
    • /
    • 2015
  • This paper investigates the droop control-based real and reactive power load sharing with a virtual inductor when the line impedance between inverter and Point of Common Coupling (PCC) is partly and unequally resistive in high-capacity systems. In this paper, the virtual inductor method is applied to parallel inverter systems with resistive and inductive line impedance. Reactive power sharing error has been improved by applying droop control after considering each line impedance voltage drop. However, in high capacity parallel systems with large output current, the reference output voltage, which is the output of droop controller, becomes lower than the rated value because of the high voltage drop from virtual inductance. Hence, line impedance voltage drop has been added to the droop equation so that parallel inverters operate within the range of rated output voltage. Additionally, the virtual inductor value has been selected via small signal modeling to analyze stability in transient conditions. Finally, the proposed droop method has been verified by MATLAB and PSIM simulation.

Design of the spiral inductor using inkjet printer (잉크젯 프린터를 이용한 나선형 인덕터 설계)

  • Kim, Jeongwo;Cho, Younghoon;Jeong, Hakyung
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.135-136
    • /
    • 2017
  • In this paper, a spiral inductor is designed and its inductance is calculated by the expended Grover method. To verify this, a rectangular planar inductor is printed by inkjet printer using conductive ink and the calculated inductance value is compared with its measured value.

  • PDF

Comparison of Active-Clamp and ZVT Techniques Applied to Tapped-Inductor DC-DC Converter with Low Voltage and Bigh Current

  • Abe, Seiya;Ninomiya, Tamotsu
    • Journal of Power Electronics
    • /
    • v.2 no.3
    • /
    • pp.199-205
    • /
    • 2002
  • This paper compares three kinds of soft-switching circuits from viewpoints of surge suppression, load characteristic, and power efficiency for a tapped-inductor buck converter with low voltage and high current. As a result, these soft-switching techniques have achieved much higher efficiency of 80 % when compared with a hard-switching buck converter for the output condition of 1V and 20A.